GENERAL<br />
<strong>Esprit</strong><br />
Natural Gas only<br />
Boiler size G.C. Appliance No. PI No.<br />
(Benchmark No.)<br />
<strong>HE</strong><strong>24</strong> 47 348 46 87 BS 051<br />
<strong>HE</strong><strong>30</strong> 47 348 47 87 BS 051<br />
<strong>HE</strong><strong>35</strong> 47 348 48 87 BS 051<br />
Destination Country:<br />
GB, IE<br />
Esp8896(1)<br />
CONTENTS<br />
Air Supply ....................................................................... 8<br />
Benchmark Commissioning Checklist ..................... 70<br />
Boiler Clearances ....................................................... 10<br />
Boiler Exploded Diagram ............................................ 15<br />
Condensate Drain .............................................11,22,23<br />
Electrical Connections ............................................... <strong>30</strong><br />
Extension Ducts - Fitting ............................................. 20<br />
Fault Finding ........................................................... 60-64<br />
Flow Wiring Diagram .................................................. 33<br />
Flue Fitting .................................................................... 18<br />
Flue Installation ............................................................. 8<br />
Gas Safety Regulations ................................................ 7<br />
Gas Supply ..................................................................... 8<br />
Installation ............................................................. 13-38<br />
Mandatory Requirements ........................................ 7-11<br />
Safe Handling ................................................................ 7<br />
Servicing ................................................................ 39-58<br />
Short List of Parts ....................................................... 65<br />
Thermostatic Radiator Valves ................................... 11<br />
Water and Systems ........................................... 8,11-13<br />
Water Connections ..................................................... 29<br />
Water Treatment ......................................................... 13<br />
Wiring Diagrams ................................................... 33-34<br />
For GB, to <strong>co</strong>mply with Building Regulations Part L1 (Part 6 in S<strong>co</strong>tland) the boiler should be fitted in ac<strong>co</strong>rdance with the<br />
manufacturer's instructions. Self-certification that the boiler has been installed to <strong>co</strong>mply with Building Regulations can be<br />
demonstrated by <strong>co</strong>mpleting and signing the Benchmark Commissioning Checklist.<br />
BENCHMARK COMMISSIONING C<strong>HE</strong>CKLIST DETAILS<br />
Boiler<br />
Page<br />
Make and model .......................................................5<br />
Appliance serial no. on data badge ...................... 14<br />
SEDBUK No. % .........................................................4<br />
Controls<br />
Time and temperature <strong>co</strong>ntrol to heating ............. 31<br />
Time and temperature <strong>co</strong>ntrol to hot water .......... 31<br />
Heating zone valves ..............................................n/a<br />
TRV's ....................................................................... 11<br />
Auto bypass ............................................................ 11<br />
Boiler interlock ........................................................ 11<br />
For all boilers<br />
Flushing to BS.7593 .............................................. 13<br />
Inhibitor .................................................................. 13<br />
Central heating mode<br />
Heat input ................................................to be calculated<br />
Page<br />
Burner operating pressure ....................................n/a<br />
Central heating flow temp. ...... measure and re<strong>co</strong>rd<br />
Central heating return temp. ... measure and re<strong>co</strong>rd<br />
For <strong>co</strong>mbination boilers only<br />
Scale reducer .........................................................n/a<br />
Hot water mode<br />
Heat input ..........................................to be calculated<br />
Max. operating burner pressure ..............................n/a<br />
Max. operating water pressure ........... measure & re<strong>co</strong>rd<br />
Cold water inlet temp ..................... measure & re<strong>co</strong>rd<br />
Hot water outlet temp. .................... measure & re<strong>co</strong>rd<br />
Water flow rate at max. setting ............ measure & re<strong>co</strong>rd<br />
For <strong>co</strong>ndensing boilers only<br />
Condensate drain .................................................. 22<br />
For all boilers: <strong>co</strong>mplete, sign & hand over to customer<br />
For assistance see Technical Helpline on the back page<br />
NOTE TO T<strong>HE</strong> INSTALLER: COMPLETE<br />
T<strong>HE</strong> BENCHMARK COMMISSIONING<br />
C<strong>HE</strong>CKLIST AND LEAVE T<strong>HE</strong>SE<br />
INSTRUCTIONS WITH APPLIANCE<br />
<strong>Esprit</strong> - Installation and Servicing<br />
5