PRIMITIVE DESCRIPTIONS<br />

CRIMSON USER MANUAL - MODULAR CONTROLLER<br />

lowest number of major divisions is one, in which case large tick-mark will be<br />

drawn at the ends of the scale, but not along its length. This property is only<br />

available when the scale is fixed.<br />

• The Minor Divisions property is used to indicate into how many minor divisions<br />

each major division should be divided. Smaller tick-marks are drawn at each<br />

division. Selecting a value of one for this property will disable minor divisions.<br />

• The minimum and maximum are tags or expressions the scale will follow to<br />

define the number of major division required. The Counts per Major Division is<br />

the number of unit between each major division. For example, if the counts is 10,<br />

the maximum 100 and the minimum 20. The full scale is 80 (100-20), therefore<br />

there will be 8 major divisions.<br />

• The Show Item property defines if the primitive should be displayed or not<br />

depending of the expression.<br />

The Color page defines the fill pattern and line style of the scale.<br />

THE FIXED TEXT PRIMITIVE<br />

The Fixed Text primitive is used to add unchanging text to a page. The text is<br />

displayed in a specified font and color, and with a specified justification. The text<br />

can also be translated for international applications.<br />

When the text is created, a cursor will appear, allowing the text to be entered…<br />

PAGE 178<br />