Specifications<br />

Physical Characteristics<br />

• Dimensions: 116mm L x 99mm W x 24mm H (4.6"L x 3.9"W x 0.95"H)<br />

• Weight: Approximately 0.20 Kg (0.44 lb.) with Heatsink<br />

Power Consumption<br />

Exact power consumption depends on the actual application. Table 2 lists power consumption for typical<br />

configurations and clock speeds.<br />

Table 2<br />

cpuModule Power Consumption<br />

Module Speed RAM Power, Typ. Heavy CPU<br />

Load<br />

Heavy CPU<br />

& Gfx Load<br />

<strong>CME34M</strong>VD1860 1.86 GHz 1024 MB 21.0 W 31.5 W 33.0 W<br />

<strong>CME34M</strong>VD1200 1.20 GHz 1024 MB 15.8 W 21.0 W 23.0 W<br />

<strong>CME34M</strong>CS1200 1.20 GHz 1024 MB 13.3 W 16.0 W 19.5 W<br />

Operating Conditions<br />

Table 3<br />

Operating Conditions<br />

Symbol Parameter Test Condition Min. Max.<br />

V CC5<br />

5V Supply Voltage 4.75V 5.25V<br />

V CC3 3.3V Supply Voltage n/a 1<br />

n/a<br />

V CC12 12V Supply Voltage n/a 1 n/a<br />

V CCSTBY 5V Standby Voltage 2<br />

4.75V 5.25V<br />

I CCSTBY<br />

5V Standby Current 2 - 500mA<br />

Ta Ambient Operating MVD1860 -40 +70C<br />

Temperature 3<br />

Ta Ambient Operating MVD1200<br />

-40 +85C<br />

Temperature 3<br />

MCS1200<br />

Ts Storage Temperature -25 +85C<br />

Rh Humidity Non-Condensing 0 90%<br />

MTBF<br />

Mean Time Before<br />

Failure<br />

23 C 275,000<br />

hours<br />

1. The 12Vand external +3.3V rails are not used by the cpuModule. Any requirements on these<br />

signals are driven by other components in the system, such as a PCI device.<br />

2. 5V Standby is used to power the board when the main supply is turned off (power down modes<br />

S3-S5). It is not required for board operation.<br />

3. With supplied heat sink solution. Depending on the CPU usage, performance may degrade as the<br />

ambient temperature approaches the maximum. Contact <strong>RTD</strong> Tech Support for more<br />

information.<br />

BDM-610000076 Rev A Chapter 1: Introduction 9