PDF File - GEC
PDF File - GEC
PDF File - GEC
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
(a) Data unit<br />
(b) Description of the data<br />
(c) Source of data<br />
The source(s) of data that will be actually used for the proposed project activity (e.g. which<br />
exact national statistics). Where several sources may be used, explain and justify which data<br />
sources should be preferred.<br />
(d) Value of data applied for the calculation of ex-ante emission reduction estimation<br />
(e) Measurement methods and procedures<br />
Where data or parameters are supposed to be measured, specify the measurement methods<br />
and procedures, including a specification which accepted industry standards or national<br />
or international standards will be applied, which measurement equipment is used, how the<br />
measurement is undertaken, which calibration procedures are applied, what is the accuracy of<br />
the measurement method, who is the responsible person / entity that should undertake the<br />
measurements and what is the measurement interval.<br />
(f) QA/QC procedures<br />
A description of the QA/QC procedures (if any) that should be applied. Below are examples of<br />
QA/QC procedures to be applied from some of the registered CDM project activities.<br />
Parameter (Examples)<br />
Total amount of landfill gas<br />
captured<br />
Quantity of HFC 23<br />
supplied to the destruction<br />
process after purity<br />
adjustment<br />
Electricity supplied to the<br />
grid by the Project<br />
Gross electricity produced<br />
QA/QC procedures to be applied (Examples)<br />
The gas management information and monitoring system will be<br />
certified under the ISO 9000 Quality Management System<br />
A QA/QC organization will be formed and QA/QC procedures that are<br />
equivalent to JIS (Japanese Industrial Standard) in terms of equipment<br />
and analytical method will be set. Will be measured using two flowmeters<br />
in parallel with weekly calibration.<br />
These data will be directly used for calculation of emission reductions.<br />
Sales record and other records are used to ensure the consistency. The<br />
electricity meter will be calibrated on a yearly basis by the electricity<br />
distributor in order to accurately monitor electricity sales.<br />
Meters will be subject to a regular maintenance and testing regime to<br />
ensure accuracy. Their readings will be double-checked by the electricity<br />
distribution company.<br />
In addition, many PDDs make general statements about the QA/QC procedures in place. Below<br />
are some examples:<br />
• Description of the quality assurance practices such as how monitoring records are taken<br />
and kept, how often the site is audited, how the personnel are trained, etc.<br />
• Statement that the project developer has a quality assurance system, e.g. ISO series, in<br />
place.<br />
(g) Comments<br />
Any comments should be stated here. Relevant background documentation should be<br />
provided in Annex 4.<br />
Project participants should also indicate the operational and management structure to implement<br />
the monitoring activities proposed in the PDD. A chart showing the organizational structure, as well<br />
as a description of the responsibilities of relevant parties and personnel, would be useful.<br />
50