BD2 System — 160 ... 1250 A<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Junction units<br />

With copper busbars<br />

Version<br />

L-units (with joint block)<br />

(fitted to Y as standard)<br />

Knee, rear<br />

Y<br />

X<br />

NSV0_00428<br />

Length/<br />

Optional length<br />

X0.36/<br />

Y0.36<br />

X0.36 ... 1.25/<br />

Y0.36<br />

X0.36/<br />

Y0.36 ... 1.25<br />

X0.36 ... 1.25/<br />

Y0.36 ... 1.25<br />

DT<br />

Rated current I n<br />

160 A, 250 A, 400 A<br />

PS*/<br />

P. unit<br />

Weight<br />

per unit<br />

approx.<br />

Type Order No. kg<br />

X BD2C-400-LH BVP:261885 1 unit 15.200<br />

X BD2C-400-LH-X* BVP:261938 1 unit 31.500<br />

X BD2C-400-LH-Y* BVP:261939 1 unit 31.500<br />

X BD2C-400-LH-X*/Y* BVP:261940 1 unit 48.200<br />

Knee, front<br />

Y<br />

X<br />

NSV0_00429<br />

X0.36/<br />

Y0.36<br />

X0.36 ... 1.25/<br />

Y0.36<br />

X0.36/<br />

Y0.36 ... 1.25<br />

X0.36 ... 1.25/<br />

Y0.36 ... 1.25<br />

X BD2C-400-<strong>LV</strong> BVP:261888 1 unit 15.200<br />

X BD2C-400-<strong>LV</strong>-X* BVP:261941 1 unit 31.500<br />

X BD2C-400-<strong>LV</strong>-Y* BVP:261942 1 unit 31.500<br />

X BD2C-400-<strong>LV</strong>-X*/Y* BVP:261943 1 unit 48.200<br />

Elbow, right<br />

Elbow, left<br />

Y<br />

Y<br />

X<br />

NSV0_00430<br />

X<br />

NSV0_00431<br />

X0.36/<br />

Y0.36<br />

X0.36 ... 1.25/<br />

Y0.36<br />

X0.36/<br />

Y0.36 ... 1.25<br />

X0.36 ... 1.25/<br />

Y0.36 ... 1.25<br />

X0.36/<br />

Y0.36<br />

X0.36 ... 1.25/<br />

Y0.36<br />

X0.36/<br />

Y0.36 ... 1.25<br />

X0.36 ... 1.25/<br />

Y0.36 ... 1.25<br />

Optional lengths: For X* and Y* you must specify the required<br />

dimension in meters from the center of the joint block to the<br />

outside edge of the trunking unit (see also page 5/80).<br />

Special colors available on request.<br />

X BD2C-400-LR BVP:261887 1 unit 13.300<br />

X BD2C-400-LR-X* BVP:261944 1 unit 30.100<br />

X BD2C-400-LR-Y* BVP:261945 1 unit 30.100<br />

X BD2C-400-LR-X*/Y* BVP:261946 1 unit 46.600<br />

X BD2C-400-LL BVP:261886 1 unit 13.300<br />

X BD2C-400-LL-X* BVP:261947 1 unit 30.100<br />

X BD2C-400-LL-Y* BVP:261948 1 unit 30.100<br />

X BD2C-400-LL-X*/Y* BVP:261949 1 unit 46.600<br />

5<br />

Version DT Type suffix Order No. PS*/<br />

P. unit<br />

Weight<br />

per unit<br />

approx.<br />

kg<br />

Fire barrier for L-units (optional)<br />

Fire barrier S120 in limb X X +BD2-S120-BX*-M* BVP:931959 1 unit 1.500<br />

Fire barrier S120 in limb Y X +BD2-S120-BY*-M* BVP:931960 1 unit 1.500<br />

For BX* or BY you must specify the required dimension in meters For the configuration of the fire barrier, see page 5/93.<br />

from the center of the joint block (for BX*: end without joint block)<br />

to the center of the fire wall or fire ceiling, for -M* specify the wall<br />

For approval in Germany:<br />

or ceiling thickness.<br />

BD2-S90(S120)-ZUL-D fire barrier kit see page 5/69.<br />

5/38 <strong>Siemens</strong> <strong>LV</strong> <strong>70</strong> · 04/<strong>2011</strong><br />

* You can order this quantity or a multiple thereof.