BD2 System — 160 ... 1250 A<br />
© <strong>Siemens</strong> AG <strong>2011</strong><br />
Junction units<br />
With copper busbars<br />
Version<br />
Length/<br />
Optional length<br />
L-units (with joint block),<br />
with engineered angle 85° ... 175°<br />
(fitted to Y as standard)<br />
Knee, rear<br />
X0.36/<br />
Y0.36<br />
X0.36 ... 1.25/<br />
Y0.36<br />
X0.36/<br />
Y<br />
Y0.36 ... 1.25<br />
85° – 175°<br />
X0.36 ... 1.25/<br />
Y0.36 ... 1.25<br />
X<br />
NSV0_00436a<br />
DT<br />
Rated current I n<br />
160 A, 250 A, 400 A<br />
PS*/<br />
P. unit<br />
Weight<br />
per unit<br />
approx.<br />
Type Order No. kg<br />
X BD2C-400-LH-G* BVP:261950 1 unit 14.<strong>70</strong>0<br />
X BD2C-400-LH-X*-G* BVP:261951 1 unit 31.500<br />
X BD2C-400-LH-Y*-G* BVP:261952 1 unit 31.500<br />
X BD2C-400-LH-X*/Y*-G* BVP:261953 1 unit 48.200<br />
Knee, front<br />
85˚ – 175˚<br />
Y<br />
X<br />
NSV0_00437<br />
X0.36/<br />
Y0.36<br />
X0.36 ... 1.25/<br />
Y0.36<br />
X0.36/<br />
Y0.36 ... 1.25<br />
X0.36 ... 1.25/<br />
Y0.36 ... 1.25<br />
X BD2C-400-<strong>LV</strong>-G* BVP:261954 1 unit 14.<strong>70</strong>0<br />
X BD2C-400-<strong>LV</strong>-X*-G* BVP:261955 1 unit 31.500<br />
X BD2C-400-<strong>LV</strong>-Y*-G* BVP:261956 1 unit 31.500<br />
X BD2C-400-<strong>LV</strong>-X*/Y*-G* BVP:261957 1 unit 48.200<br />
5<br />
Elbow, right<br />
Y<br />
Elbow, left<br />
Y<br />
X<br />
85˚ – 175˚<br />
NSV0_00438<br />
X<br />
85˚-175˚<br />
NSV0_00439<br />
X0.36/<br />
Y0.36<br />
X0.36 ... 1.25/<br />
Y0.36<br />
X0.36/<br />
Y0.36 ... 1.25<br />
X0.36 ... 1.25/<br />
Y0.36 ... 1.25<br />
X0.36/<br />
Y0.36<br />
X0.36 ... 1.25/<br />
Y0.36<br />
X0.36/<br />
Y0.36 ... 1.25<br />
X0.36 ... 1.25/<br />
Y0.36 ... 1.25<br />
Elbow: For G* you must specify the required number of degrees<br />
in 5° increments.<br />
Optional lengths: For X* and Y* you must specify the required<br />
dimension in meters from the center of the joint block to the<br />
outside edge of the trunking unit (see also page 5/80).<br />
Special colors available on request.<br />
X BD2C-400-LR-G* BVP:261958 1 unit 13.300<br />
X BD2C-400-LR-X*-G* BVP:261959 1 unit 30.100<br />
X BD2C-400-LR-Y*-G* BVP:261960 1 unit 30.100<br />
X BD2C-400-LR-X*/Y*-G* BVP:261961 1 unit 46.600<br />
X BD2C-400-LL-G* BVP:261962 1 unit 13.300<br />
X BD2C-400-LL-X*-G* BVP:261963 1 unit 30.100<br />
X BD2C-400-LL-Y*-G* BVP:261964 1 unit 30.100<br />
X BD2C-400-LL-X*/Y*-G* BVP:261965 1 unit 46.600<br />
Version DT Type suffix Order No. PS*/<br />
P. unit<br />
Weight<br />
per unit<br />
approx.<br />
kg<br />
Fire barrier for L-units (optional)<br />
Fire barrier S120 in limb X X +BD2-S120-BX*-M* BVP:931959 1 unit 1.500<br />
Fire barrier S120 in limb Y X +BD2-S120-BY*-M* BVP:931960 1 unit 1.500<br />
For BX* or BY you must specify the required dimension in meters For the configuration of the fire barrier, see page 5/93.<br />
from the center of the joint block (for BX*: end without joint block)<br />
to the center of the fire wall or fire ceiling, for -M* specify the wall<br />
For approval in Germany:<br />
or ceiling thickness.<br />
BD2-S90(S120)-ZUL-D fire barrier kit see page 5/69.<br />
5/42 <strong>Siemens</strong> <strong>LV</strong> <strong>70</strong> · 04/<strong>2011</strong><br />
* You can order this quantity or a multiple thereof.