Catalog LV 70 2011 - Low & Medium Voltage - Siemens
Catalog LV 70 2011 - Low & Medium Voltage - Siemens
Catalog LV 70 2011 - Low & Medium Voltage - Siemens
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
BD01 System — 40 ... 160 A<br />
© <strong>Siemens</strong> AG <strong>2011</strong><br />
Tap-off units for the United Kingdom<br />
■ Selection and ordering data<br />
DT Type Order No. Version<br />
Rated current Rated<br />
Weight<br />
voltage U e approx.<br />
I n<br />
operational<br />
PS*/<br />
P. unit per unit<br />
A V kg<br />
Tap-off units, aluminum, size 1<br />
With 1-pole fuse base NNS-32<br />
• Without socket outlet 32 230 X BD01-AK1X/GB321 BVP:203119 1 unit 1.100<br />
• With 2 socket outlets BS1363 13 A 13 230 X BD01-AK1X/<br />
2BS133GB131<br />
BVP:203121 1 unit 1.900<br />
With 3-pole fuse base 3 × NNS-32 32 400 X BD01-AK1X/GB323 BVP:203120 1 unit 1.300<br />
With 1-pole miniature circuit breaker 13 A,<br />
characteristic B, and<br />
with 2 socket outlets BS1363, 13 A<br />
13 230 X BD01-AK1X/<br />
2BS133A131<br />
BVP:203122 1 unit 1.720<br />
4<br />
Tap-off units, aluminum, size 1, with device installation unit<br />
With 3 × 1-pole miniature circuit breaker 32 A,<br />
characteristic C<br />
32 400 X BD01-AK1M1/A321 BVP:203118 1 unit 1.600<br />
Tap-off units, aluminum, size 2<br />
With 3 × 1-pole fuse base NNS-32<br />
• With 1 CEE socket outlet 16 A, 5-pole 16 400 X BD01-AK2X/<br />
CEE165GB163<br />
• With 1 CEE socket outlet 32 A, 5-pole 32 400 X BD01-AK2X/<br />
CEE325GB323<br />
Tap-off units, aluminum, size 2, with device installation unit<br />
With 1-pole miniature circuit breaker 13 A, characteristic B, 13 230 X BD01-AK2M1/<br />
with 2-pole residual current operated circuit breaker<br />
BS133FIA131<br />
(RCCB) 16 A/30 mA and with 1 socket outlet BS1363, 13 A<br />
BVP:203124 1 unit 2.000<br />
BVP:203125 1 unit 2.100<br />
BVP:203123 1 unit 2.500<br />
NSV0_00268<br />
NSV0_00256<br />
NSV0_00252<br />
NSV0_00267<br />
NSV0_00249<br />
NSV0_00267<br />
NSV0_00249<br />
Country-specific tap-off units can only be ordered in the relevant<br />
country. Send inquiries to the local regional company.<br />
Fuse links are not included in scope of supply.<br />
Use plastic cable glands with strain relief (not included in scope<br />
of supply).<br />
4/24 <strong>Siemens</strong> <strong>LV</strong> <strong>70</strong> · 04/<strong>2011</strong><br />
* You can order this quantity or a multiple thereof.