BD01 System — 40 ... 160 A<br />
Introduction<br />
Tap-off units for free arrangement of components<br />
• One size with 3 MW space requirement (1 MW = 18 mm), for<br />
operation from the outside through a hinge switch integrated<br />
in the cover.<br />
• Installation of devices (e.g. miniature circuit breakers) according<br />
to DIN 43871 up to and including 32 A possible<br />
Tap-off units for free arrangement of components<br />
• Two sizes with 4 MW and 8 MW space requirement<br />
(1 MW = 18 mm; MW = modular width)<br />
• Without or with device installation unit for external actuation<br />
(two sizes with 4 MW and 8 MW)<br />
• Installation of devices (e.g. miniature circuit breakers) according<br />
to DIN 43871 up to and including 63 A possible<br />
BD01-AK02M0/F<br />
Tap-off units made of aluminium<br />
Common features<br />
• The enclosure is made from aluminum and molded plastic at<br />
both ends.<br />
• A standard mounting rail is built-in for component mounting.<br />
• Power pick-up through silver-plated lyre-shaped contacts<br />
• The isolator built into the tap-off unit ensures that the tap-off<br />
unit is voltage-free when the cover is open.<br />
• The tap-off unit can only be fitted to or removed from the tapoff<br />
point with its cover open (contacts retracted).<br />
• Reliable prevention of incorrect mounting<br />
• Cable entry is possible from three directions (use plastic cable<br />
glands with strain relief; not included in scope of supply).<br />
• Can be combined with ancillary equipment units for additional<br />
functions.<br />
• The connecting cables should be supported separately if necessary.<br />
Tap-off units with components fitted<br />
• Two sizes with 4 MW or 8 MW space requirement<br />
(1 MW = 18 mm)<br />
• Various versions with fuse bases, miniature circuit breakers up<br />
to and including 63 A, with SCHUKO and CEE socket outlets<br />
up to and including 32 A<br />
• Versions with fitted miniature circuit breaker have a device<br />
installation unit.<br />
BD01-AK1M1/F<br />
Country-specific tap-off units<br />
These tap-off units contain equipment according to typical national<br />
requirements, such as special socket outlets.<br />
Ancillary equipment units<br />
The ancillary equipment units are used for expanding the tap-off<br />
units or infeeds used. They can be mounted to the side of them.<br />
Common features<br />
• The enclosure is made from aluminum and molded plastic at<br />
both ends.<br />
• Cable entry is possible from four directions (use plastic cable<br />
glands with strain relief; not included in scope of supply).<br />
• The connecting cable should be supported separately if necessary.<br />
• Can be combined with tap-off or feeder units<br />
• A standard mounting rail is built-in for component mounting.<br />
• Two sizes with 4 MW and 8 MW space requirement<br />
(1 MW = 18 mm)<br />
• Without or with SCHUKO or CEE socket outlets<br />
• Without or with device installation unit for external operation<br />
(two sizes with 4 MW and 8 MW)<br />
• Installation of devices (e.g. fuse bases) according to<br />
DIN 43871 up to and including 35 A possible.<br />
4<br />
BD01-AK1M1/A163<br />
BD01-GK2X/F<br />
NSV0_00056<br />
NSV0_00319<br />
NSV0_00057<br />
NSV0_00058<br />
NSV0_00055<br />
NSV0_00077<br />
BD01-AK2M1/ CEE165A163<br />
BD01-GK1X/... (left) with BD01-AK2M2/... (right)<br />
<strong>Siemens</strong> <strong>LV</strong> <strong>70</strong> · 04/<strong>2011</strong><br />