NSV0_00462<br />

NSV0_00464<br />

NSV0_00464<br />

NSV0_00464<br />

NSV0_00464<br />

NSV0_00461<br />

BD2 System — 160 ... 1250 A<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Tap-off units for Switzerland<br />

DT Type Order No. Version<br />

Miniature circuit Rated current Rated<br />

Weight<br />

voltage U e approx.<br />

breakers (MCBs) I n<br />

operational<br />

PS*/<br />

P. unit per unit<br />

A V kg<br />

Molded-plastic enclosures, size 2, up to 63 A<br />

With miniature circuit breaker Characteristic C<br />

• Without socket outlet 3-pole, 25 A 25 400 X BD2-AK2M2/A253 BVP:611331 1 unit 4.600<br />

3-pole, 40 A 40 400 X BD2-AK2M2/A403 BVP:611332 1 unit 4.600<br />

3-pole, 63 A 63 400 X BD2-AK2M2/A633 BVP:611333 1 unit 4.900<br />

• With 1 socket outlet type 23, 16 A<br />

and 1 CEE socket outlet, 5-pole, 16 A<br />

1-pole, 16 A;<br />

3-pole, 16 A<br />

16 230, 400 X BD2-AK2M2/<br />

T23-A161/<br />

CEE165-A163<br />

BVP:611326 1 unit 5.400<br />

• With 1 socket outlet type 25, 16 A<br />

and 1 CEE socket outlet, 5-pole, 16 A<br />

2 × 3-pole, 16 A 16 400 X BD2-AK2M2/<br />

T25-CEE165-2A163<br />

BVP:611327 1 unit 5.<strong>70</strong>0<br />

• With 1 socket outlet type 23, 16 A<br />

and 1 CEE socket outlet, 5-pole, 32 A<br />

1-pole, 16 A;<br />

3-pole, 32 A<br />

16, 32 230, 400 X BD2-AK2M2/<br />

T23-A161/<br />

CEE325-A323<br />

BVP:611328 1 unit 5.500<br />

• With 1 socket outlet type 25, 16 A<br />

and 1 CEE socket outlet, 5-pole, 32 A<br />

3-pole, 16 A;<br />

3-pole, 32 A<br />

16, 32 400 X BD2-AK2M2/<br />

T25-A163/<br />

CEE325-A323<br />

BVP:611329 1 unit 5.<strong>70</strong>0<br />

5<br />

With miniature circuit-breaker and<br />

RCCB<br />

• With 1 socket outlet type 25, 16 A<br />

Characteristic C<br />

3-pole, 16 A<br />

4-pole residual-current<br />

circuit breaker<br />

25 A/30 mA<br />

16 400 X BD2-AK2M2/<br />

T25-FI254-A163<br />

BVP:611325 1 unit 4.900<br />

Country-specific tap-off units can only be ordered in the relevant<br />

country. Send inquiries to the local regional company.<br />

Special colors available on request.<br />

5/66 <strong>Siemens</strong> <strong>LV</strong> <strong>70</strong> · 04/<strong>2011</strong><br />

* You can order this quantity or a multiple thereof.