Remote Control and Monitoring<br />

• The Ether<strong>net</strong> connector supports direct and switched Tel<strong>net</strong> connections to port 61408.<br />

Note:<br />

Note the port number. Tel<strong>net</strong> programs default to port 23. You must<br />

correctly enter 61408 to connect to the <strong>CP750</strong>.<br />

The system accepts 20 simultaneous connections on the TCP port concurrent with one<br />

on each of the other ports. The 21st TCP connection causes the oldest TCP session to<br />

disconnect, and sends a warning message to the client.<br />

• The Remote RJ‐45 connector operates at 9600 bps with 8 data bits, 1 stop bit, no parity,<br />

and no flow control.<br />

Characters are not echoed back to the controller, and the Ether<strong>net</strong> and Remote connections<br />

do not support terminal control characters such as . The RS-232 connector<br />

does support terminal control characters and is therefore the most user friendly.<br />

6.2.2 Standard and Full Control<br />

Under normal operating conditions, a user needs only a subset of all the available<br />

commands. But installers and expert users need and want full control of the system. The<br />

standard command set is available when cp750.ctrl.full_ascii_ctrl is 0. The full<br />

command set is available when cp750.ctrl.full_ascii_ctrl is 1.<br />

6.2.3 Command Syntax<br />

Command parsing is not case sensitive. White space is ignored on input lines.<br />

Most commands consist of a parameter name followed by a space and a value.<br />

cp750.sys.input_mode dig_2 instructs the system to use digital input 2.<br />

The system responds with status text verifying that the value has been set:<br />

cp750.sys.input_mode dig_2<br />

Queries consist of a parameter name followed by a space and a question mark.<br />

cp750.sys.input_mode ? asks which input the system is currently using.<br />

The system responds with status text for the specified parameter.<br />

cp750.sys.input_mode dig_2<br />

If you send an unrecognized value, the system takes no action and returns parameter<br />

status. If you send an unrecognized parameter, the system returns a blank new line. No<br />

error messages are generated.<br />

There is also a small set of single word commands such as help, status, and exit.<br />

48 <strong>Dolby</strong> ® <strong>CP750</strong> <strong>Digital</strong> <strong>Cinema</strong> <strong>Processor</strong> <strong>Manual</strong>