Example<br />

NTADDR172,34,54,123 ; Set the IP address of the Gem6K<br />

OPTEN0<br />

; Disable the option card (for Fieldbus units<br />

only)<br />

RESET<br />

NTFEN2<br />

; Enable network function on Gem6K<br />

RESET<br />

5NTIP1,172,34,54,124 ; Identify network server #5 as an Allen Bradley<br />

PLC<br />

; at IP address 172.34.54.124<br />

5NTCONN1 ; Connect to network server #5<br />

5NTMPRB11,7,1,106 ; File 11, element 7 in the AB PLC is mapped to<br />

the Gem6K's<br />

; binary variable VARB106<br />

5NTMPRI20,5,2,128 ; File 20, elements 5-6 in the AB PLC are mapped<br />

to<br />

; the Gem6K's integer variables VARI128-VARI129,<br />

respectively<br />

5NTMPWB11,3,4,100 ; File 11, elements 3-6, in the AB PLC are<br />

mapped to<br />

; the Gem6K's binary variables VARB100-VARB103<br />

5NTMPWI20,3,2,120 ; File 20, elements 3-4, in the AB PLC are<br />

mapped to<br />

; the Gem6K's integer variables VARI120-VARB121<br />

5NTPOLL50<br />

; Start polling network server #5, set interval<br />

to 50 ms.<br />

;<br />

*********************************************<br />

************************<br />

; The Gem6K's VARB106 will read from the PLC's File 11, element 7.<br />

; The Gem6K's VARI128-VARI129 will read from the PLC's File 20,<br />

elements 5-6.<br />

; The PLC's File 11, elements 3-6 will read from the Gem6K's<br />

VARB100-VARB103.<br />

; The PLC's File 20, elements 3-4 will read from the Gem6K's<br />

VARI120-VARB121.<br />

;<br />

*********************************************<br />

************************<br />

Program<br />

Interaction<br />

After the connection is established, mapping has been set up, <strong>and</strong> polling enabled, the Gem6K<br />

starts exchanging data automatically with the PLC. Here is how to:<br />

• Write a binary variable to the PLC: Simply write a value to one of the VARB variables in<br />

the NTMPWB mapping. The new data will be written to the binary file during the next poll.<br />

• Write an integer variable to the PLC: Simply write a value to one of the VARI variables in<br />

the NTMPWI mapping. The new data will be written to the integer file during the next poll.<br />

• Read a binary variable from the PLC: The VARB variables in the NTMPRB mapping<br />

correspond to the values in the binary file in the PLC.<br />

• Read an integer variable from the PLC: The VARI variables in the NTMPRI mapping<br />

correspond to the values in the integer file in the PLC.<br />

Chapter 2. Communication 53