Friday <strong>AM</strong><br />

11:06 747. Anomalous Noise Behaviour in ZTE Imaging<br />

Markus Weiger 1,2 , Klaas Paul Pruessmann 3<br />

1 Bruker BioSpin AG, Faellanden, Switzerland; 2 Bruker BioSpin MRI GmbH, Ettlingen, Germany; 3 Institute for Biomedical<br />

Engineering, University & ETH Zurich, Zurich, Switzerland<br />

11:18 748. Highly-Accelerated Real-Time Cine MRI using Compressed Sensing & Parallel Imaging with Cardiac Motion<br />

Constrained Reconstruction<br />

Li Feng 1 , Ricardo Otazo 2 , Monvadi B. Srichai 2,3 , Ruth P. Lim 2 , Daniel K. Sodickson 2 , Daniel Kim 2<br />

1 Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, USA; 2 Radiology, New<br />

York University School of Medicine, New York, USA; 3 Medicine, New York University School of Medicine, New York, USA<br />

11:30 749. High Spatial & Temporal Resolution Cardiac Imaging Reconstructed from Real-Time Golden Angle Radial<br />

Acquisitions using Motion Correction & Parallel Imaging<br />

Michael Schacht Hansen 1 , Thomas Sangild Sørensen 2 , Peter Kellman 1<br />

1 National Heart, Lung & Blood Institute, National Institutes of Health, Bethesda, MD, USA; 2 Department of Computer Science,<br />

Aarhus University, Aarhus, Denmark<br />

11:42 750. Correction of Signal Loss in HYPR FLOW Reconstruction<br />

Yijing Wu 1 , Steven Kecskemeti 1 , Patrick A. Turski, Charles A. Mistretta<br />

1 Medical Physics, University of Wisconsin, Madison, MADISON, WI, USA<br />

11:54 751. Closed-Form Solution for the Three-Point Dixon Method with Advanced Spectrum Modeling<br />

Johan Berglund 1 , Håkan Ahlström 1 , Lars Johansson 1 , Joel Kullberg 1<br />

1 Oncology, Radiology & Clinical Immunology, Uppsala University, Uppsala, Sweden<br />

12:06 752. Spiral Water-Fat Imaging with Integrated Off-Resonance Correction on a Clinical Scanner<br />

Holger Eggers 1 , Peter Boernert 1 , Peter Koken 1<br />

1 Philips Research, Hamburg, Germany<br />

12:18 753. Addressing Phase Errors in Fat-Water Imaging using a Mixed Magnitude/Complex Fitting Method<br />

Diego Hernando 1 , Catherine D. G. Hines 1 , Huanzhou Yu 2 , Scott B. Reeder 1,3<br />

1 Radiology, University of Wisconsin, Madison, WI, USA; 2 Global Applied Science Laboratory, GE Healthcare, Menlo Park, CA,<br />

USA; 3 Medical Physics, University of Wisconsin, Madison, WI, USA<br />

Cancer: Multi Modal Imaging Including PRI/MRI<br />

Room 518-A-C 10:30-12:30 Moderators: Zahi A. Fayad & Martin O. Leach<br />

10:30 754. Introduction<br />

Zahi A. Fayad<br />

10:42 755. FDG-PET Imaging with First Combined Whole-Body MR-PET vs. Conventional PET/CT: Qualitative &<br />

Quantitative Comparison of Results<br />

DAVID IZQUIERDO-GARCIA 1 , VALENTIN FUSTER 2,3 , JEFFREY KASTE 4 , TROY HAVENS 4 , GARY MUSWICK 5 ,<br />

NAVDEEP OJHA 4 , ZHIQIANG HU 4 , JOSEF MACHAC 6 , ZAHI A. FAYAD 1,2<br />

1 2<br />

Translational & Molecular Imaging Institute, Mount Sinai School of Medicine, New York, NY, USA; Department of Cardiology,<br />

Zena & Michael A. Weiner Cardiovascular Institute, Mount Sinai School of Medicine, New York, NY, USA; 3 Department of<br />

Cardiology, Marie-Josée & Henry R. Kravis Cardiovascular Health Center, Mount Sinai School of Medicine, New York, NY, USA;<br />

4 5 6<br />

Philips Healthcare, Cleveland, OH, USA; Philips Healthcare, Cleveland, OH, USA; Division of Nuclear Medicine, Department of<br />

Radiology, Mount Sinai School of Medicine, New York, NY, USA<br />

10:54 756. The Effect of MR Acoustic Noise on FDG-PET Uptake in a Simultaneous MR/PET System<br />

Daniel Burje Chonde 1,2 , Nasreddin Abolmaali 3 , Alma Gregory Sorensen 1 , Ciprian Catana 1<br />

1 Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA, USA; 2 Department of Biophysics, Harvard University,<br />

Cambridge, MA; 3 OncoRay - Center for Radiation Research in Oncology, Dresden, Germany<br />

11:06 757. Comparison of Diffusion Weighted Imaging with [ 18 F]-FLT Uptake in a Human Colon Cancer Xenograft Model<br />

using Treatment Strategies<br />

Valerie Simone Honndorf 1 , Sally-Ann Ricketts 2 , Jane Halliday 2 , Hans F. Wehrl 3 , Stefan Wiehr 3 , Damaris Kukuk 3 ,<br />

Maren K. Koenig 3 , Mareike Lehnhoff 3 , Julia Mannheim 3 , Gerald Reischl 4 , Bernd J. Pichler 3<br />

1 Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens-Foundation , University of Tuebingen,<br />

Tuebingen, Germany; 2 Imaging, Translational Sciences, AstraZeneca, Alderley Park, Macclesfield, Cheshire, United Kingdom;<br />

3 Laboratory for Preclinical Imaging & Imaging Technology of the Werner Siemens-Foundation, University of Tuebingen, Tuebingen,<br />

Germany; 4 Radiopharmacy & PET-Center, University of Tuebingen, Tuebingen, Germany<br />