MAINTENANCE<br />

C. TRANSMISSION (See Page 7-23)<br />

1. Pump<br />

Transmission<br />

2. Swing<br />

Reduction<br />

Gear<br />

3. Travel<br />

Reduction<br />

Gear<br />

Parts<br />

Quantity<br />

Oil Level Check 1<br />

ZX180-3, 200-3, 270-3 1.0 L<br />

Class<br />

(1.1 US qt)<br />

Change<br />

1.4 L<br />

ZX330-3 Class<br />

(1.5 US qt)<br />

Oil Level Check 1<br />

3.2 L<br />

ZX120-3 Class<br />

(3.4 US qt)<br />

6.2 L<br />

ZX180-3, 200-3 Class<br />

(1.6 US gal)<br />

ZX270-3 Class (Except 9.1 L<br />

Change<br />

280LC-3, 280LCN-3) (2.4 US gal)<br />

11.7 L<br />

ZX280LC-3, 280LCN-3<br />

(3.1 US gal)<br />

17.0 L<br />

ZX330-3 Class<br />

(4.5 US gal)<br />

Oil Level Check 2<br />

4.0 L ×2<br />

ZX120-3 Class<br />

(4.2 US qt)<br />

6.8 L ×2<br />

ZX180-3, 200-3 Class<br />

(1.8 US gal)<br />

Change<br />

ZX270-3 Class (Except 7.8 L ×2<br />

280LC-3, 280LCN-3) (2.1 US gal)<br />

ZX280LC-3, 280LCN-3, 9.2 L ×2<br />

330-3 Class<br />

(2.4 US gal)<br />

Interval (hours)<br />

8 50 100 250 500 1000 2000<br />

D. HYDRAULIC SYSTEM (See Page 7-27)<br />

Parts<br />

Quantity<br />

8 50 100<br />

Interval (hours)<br />

250 300 500 1000 1500 2500 5000<br />

1. Check Hydraulic Oil Level 1<br />

ZX120-3 Class<br />

130 L<br />

(34.3 US gal)<br />

✸ ✸ ✸ ✸<br />

ZX180-3 Class<br />

190 L<br />

(50.2 US gal)<br />

✸ ✸ ✸ ✸<br />

ZX210-3,<br />

200 L<br />

2. Change Hydraulic 210LC-3 (52.8 US gal)<br />

✸ ✸ ✸ ✸<br />

Oil<br />

ZX210LCN-3, 170 L<br />

240N-3<br />

(44.9 US gal)<br />

✸ ✸ ✸ ✸<br />

ZX270-3 Class<br />

243 L<br />

(64.2 US gal)<br />

✸ ✸ ✸ ✸<br />

ZX330-3 Class<br />

298 L<br />

(78.7 US gal)<br />

3. Suction Filter Cleaning 1 When changing hydraulic oil<br />

4. Replace Hydraulic Oil Tank Filter 1 ✸✸ ✸ ✸<br />

5. Replace Pilot Oil Filter 1<br />

6. Replace Air Breather Element 1<br />

7. Check Hoses and<br />

Lines<br />

for leaks –<br />

for cracks, bend, etc. –<br />

NOTE: ✸ Changing interval differs according to the brand of hydraulic oil used, kind of filter element or average attachment<br />

operating availability. Refer to the “changing intervals of hydraulic oil and full flow filter element” on page 7-29.<br />

See recommended oil chart.<br />

✸✸ While demolition and logging work.<br />

7-11