Switch(Config-Vlan100)#switchport interface ethernet 1/2-6<br />

Switch(Config-Vlan100)#exit<br />

Switch(Config)#interface Ethernet 1/11<br />

Switch(Config-Ethernet1/11)#switchport mode trunk<br />

Switch(Config-Ethernet1/11)# bridge-ext gvrp<br />

Switch(Config-Ethernet1/11)#exit<br />

Switch B:<br />

Switch(Config)# bridge-ext gvrp<br />

Switch(Config)#interface ethernet 1/10<br />

Switch(Config-Ethernet1/10)#switchport mode trunk<br />

Switch(Config-Ethernet1/10)# bridge-ext gvrp<br />

Switch(Config-Ethernet1/10)#exit<br />

Switch(Config)#interface ethernet 1/11<br />

Switch(Config-Ethernet1/11)#switchport mode trunk<br />

Switch(Config-Ethernet1/11)# bridge-ext gvrp<br />

Switch(Config-Ethernet1/11)#exit<br />

Switch C:<br />

Switch(Config)# bridge-ext gvrp<br />

Switch(Config)#vlan 100<br />

Switch(Config-Vlan100)#switchport interface ethernet 1/2-6<br />

Switch(Config-Vlan100)#exit<br />

Switch(Config)#interface ethernet 1/11<br />

Switch(Config-Ethernet1/11)#switchport mode trunk<br />

Switch(Config-Ethernet1/11)# bridge-ext gvrp<br />

Switch(Config-Ethernet1/11)#exit<br />

VLAN Troubleshooting<br />

The GARP counter setting in for Trunk ports in both ends of Trunk link must be the same,<br />

otherwise GVRP will not work properly.It is recommended to avoid enabling GVRP and<br />

RSTP at the same time in ES4624-<strong>SFP</strong>/<strong>ES4626</strong>-<strong>SFP</strong> switch. If GVRP is to be enabled,<br />

RSTP function for the ports must be disabled first.<br />

5.2.5 GVRP Troubleshooting<br />

• The GARP counter setting in for Trunk ports in both ends of Trunk link must be the<br />

same, otherwise GVRP will not work properly.It is recommended to avoid enabling<br />

GVRP and RSTP at the same time in ES4624-<strong>SFP</strong>/<strong>ES4626</strong>-<strong>SFP</strong> switch. If GVRP is<br />