10.07.2015 Views

Merlins Ralliart and EvoX TUNING GUIDE Version K.pdf - EvoScan

Merlins Ralliart and EvoX TUNING GUIDE Version K.pdf - EvoScan

Merlins Ralliart and EvoX TUNING GUIDE Version K.pdf - EvoScan

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MERLINS RALLIART & EVOLUTION-X <strong>TUNING</strong> <strong>GUIDE</strong>A6.2-P01XX Fuel <strong>and</strong> Air MeteringP0100 Mass or Volume Air Flow CircuitP0101 Mass or Volume Air Flow Circuit Range/Performance ProblemP0102 Mass or Volume Air Flow Circuit Low InputP0103 Mass or Volume Air Flow Circuit High InputP0104 Mass or Volume Air Flow Circuit IntermittentP0105P0106P0107P0108P0109P0110P0111P0112P0113P0114P0115P0116P0117P0118P0119P0120P0121P0122P0123P0124P0125P0126P0127P0128Manifold Absolute Pressure/Barometric Pressure CircuitManifold Absolute Pressure/Baro. Pressure Circuit Range/Perf. ProblemManifold Absolute Pressure/Barometric Pressure Circuit Low InputManifold Absolute Pressure/Barometric Pressure Circuit High InputManifold Absolute Pressure/Barometric Pressure Circuit IntermittentIntake Air Temperature CircuitIntake Air Temperature Circuit Range/Performance ProblemIntake Air Temperature Circuit Low InputIntake Air Temperature Circuit High InputIntake Air Temperature Circuit IntermittentEngine Coolant Temperature CircuitEngine Coolant Temperature Circuit Range/Performance ProblemEngine Coolant Temperature Circuit Low InputEngine Coolant Temperature Circuit High InputEngine Coolant Temperature Circuit IntermittentThrottle/Pedal Position Sensor/Switch A CircuitThrottle/Pedal Position Sensor/Switch A Circuit Range/Perf. ProblemThrottle/Pedal Position Sensor/Switch A Circuit Low InputThrottle/Pedal Position Sensor/Switch A Circuit High InputThrottle/Pedal Position Sensor/Switch A Circuit IntermittentInsufficient Coolant Temperature for Closed Loop Fuel ControlInsufficient Coolant Temperature for Stable OperationIntake Air Temperature Too HighCoolant Temperature < Thermostat Reg. Temp.)P0130 O2 Sensor Circuit (Bank 1 Sensor 1)P0131 O2 Sensor Circuit Low Voltage (Bank 1 Sensor 1)P0132 O2 Sensor Circuit High Voltage (Bank 1 Sensor 1)P0133 O2 Sensor Circuit Slow Response (Bank 1 Sensor 1)P0134 O2 Sensor Circuit No Activity Detected (Bank 1 Sensor 1)P0135 O2 Sensor Heater Circuit (Bank 1 Sensor 1)P0136 O2 Sensor Circuit Malfunction (Bank 1 Sensor 2)P0137 O2 Sensor Circuit Low Voltage (Bank 1 Sensor 2)P0138 O2 Sensor Circuit High Voltage (Bank 1 Sensor 2)P0139 O2 Sensor Circuit Slow Response (Bank 1 Sensor 2)P0140 O2 Sensor Circuit No Activity Detected (Bank 1 Sensor 2)P0141 O2 Sensor Heater Circuit (Bank 1 Sensor 2)REV: 0.K merlin@three.com.au Page 124 of 134

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!