Fluke 700 Pxx Series Pressure Modules<br />
FLU,700pxx NZ<br />
Assortment of pxx series pressure modules for the Fluke 741/744 process<br />
calibrators.<br />
Druck DBC150TC Dry Well Calibrator Calibrator<br />
DRU,DbC150TC AU<br />
Temperature range -45(below ambient)~150ºC. Accuracy 0.3ºC, resolution<br />
0.01ºC, stability 0.03ºC. Well standard insert supplied 145mm deep, 5, 6.6<br />
& 9.8mmØ. Heating time 14min 20~120ºC, cooling time 22min 25~-20ºC.<br />
Calibrator also measures sensor outputs, it can measure 5 types of RTD<br />
& 11 types of thermocouple. Supports 2, 3, 4 wire RTD and provides cold<br />
junction compensation for thermocouples.<br />
Hart 9105 Dry Block Temperature Calibrator -25~140ºC NATA<br />
HAR,9105-NATA AU<br />
HAR,9105 MY<br />
Range -25~140ºC, accuracy 0.1, resolution 0.01, stability 0.02. RS232<br />
interface for ramp and soak programming. Well dimensions 150mm deep,<br />
19, 5, 3 & (2x) 6mmØ. Heats and cools in less than 10min. NATA certified.<br />
Hart 9107 Dry Block Temperature Calibrator -45~140ºC NATA<br />
HAR,9107-NATA AU<br />
Range -45~140ºC, accuracy 0.1, resolution 0.01, stability 0.02. RS232<br />
interface for ramp and soak programming. Well dimensions 150mm deep,<br />
19, 5, 3 & (2x) 6mmØ. Heats and cools in less than 10min. NATA certified.<br />
> NEW Hart 9170-R Metrology Well Calibrator with Built-in<br />
Reference & NATA Certification<br />
HAR,9170-R-NATA AU<br />
Temperature range -45~140ºC with bult in reference thermometry. Reference<br />
input accepts (not supplied) 100, 25 and 10ohm pRT’s. Display accuracy +/-<br />
0.1ºC, stability +/-0.005ºC full range, resolution 0.001ºC. Well depth 6.3”,<br />
insert type A 1/4, 3/16, 1/4, 1/8, 1/4, 3/8”. Large LCD, numeric keypad and<br />
on screen menus. Heating time 32min 23~140ºC, 45 minutes -45~140ºC,<br />
cooling time 44min 23~-45ºC, 19min 140~23ºC. Supplied with RS232C<br />
interface and CD-ROM software.<br />
Hart 9100-A Dry Block Temperature Calibrator 30~300OC<br />
HAR,9100-A NZ<br />
Stability is 0.2ºC @ 50OC & 0.3ºC @ 300ºC. Accuracy for 35~200ºC ±0.5<br />
for 200~300ºC ±1, for well holes greater than ¼” ±2ºC.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
induStrial calibratOrS<br />
> NEW Hart 3125 Surface Probe Calibrator 35~400ºC NATA<br />
Certification<br />
HAR,3125-NATA AU<br />
Temperature range 35~400ºC. Display accuracy ±0.5~200ºC, ±1~400ºC.<br />
Stability ±0.2~300ºC, ±0.3~400ºC. Resolution 0.01º. Heating time<br />
25~400ºC 22min. Cooling time 400~100ºC 65min. Temperature surface<br />
plate 3.8ӯ accessible.<br />
Hart 9141 Dry Block Temperature Calibrator 50~650ºC<br />
HAR,9141-NATA AU<br />
Range 50~650ºC, basic accuracy 0.5% (holes > ¼” 2ºC). Insert hole sizes<br />
1/16”, 1/8”, 3/16”, ¼”, 3/8” & ½”. Includes pC software and interface cable.<br />
Heating time 1min to 650ºC. Cooling 25min from 650ºC~100ºC. Well depth<br />
4.875”. Stabilization time 7min.<br />
Hart 9150 Furnace 150-1200ºC<br />
HAR,9150 AU<br />
Temperature range 150~1200ºC. Stability ±0.5ºC, display accuracy of ±5ºC<br />
across entire range. Display resolution 0.1º~999.9ºC, 1º above 1,000ºC.<br />
Well diameter 1.25”, well depth 5.5”, insert type A. 1/16”, ¼”, ⅜”, 3/16”, ⅛”,<br />
½”. Heating time 35min to 1,200ºC, cooling time 140min.<br />
Jofra 1200SE Precision Temperature Calibrator<br />
JOF,1200SE MY<br />
Lightweight, portable for lab and general use. Simple single step zero setting.<br />
Temperature range 300~1200ºC. Excellent performance characteristics.<br />
Accuracy +2ºC. Stability +0.5ºC. Display in ºC or ºF to 0.1 resolution. Fast<br />
cooling and heating. User-selectable slope rates for controlled thermo switch<br />
testing. Self diagnostics includes semi-auto Switch Test & Hysteresis Test.<br />
Grant W6 Temperature Bath NATA Certified<br />
GRA,W6-NATA AU<br />
Water/oil bath calibrator for calibrating temperature probes. Ranges water<br />
ambient 100ºC; silicon oil ambient; 150ºC. Requires 3L oil (not supplied).<br />
Digital temperature controller and display. Stability 0.004ºC. Uniformity<br />
0.01ºC. Display resolution 0.1ºC. Tank size 300w x 150d x 150hmm.<br />
GENERAL INDUS<strong>TR</strong>IAL EQUIPMENT<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 97