AIR CONDITIONING & AIR QUALITY - HVAC & IAQ<br />

114<br />

air flOW meaSurement/air quality<br />

Model Type<br />

TSI,8520<br />

Particle measurement<br />

Temp<br />

O C<br />

RH%<br />

CO<br />

ppm<br />

CO 2<br />

ppm<br />

NO<br />

ppm<br />

Dust & Aerosol Notes<br />

0.001~100mg/m 3<br />

0.1~10µ<br />

AbA,301 0.3~5µ<br />

TSI,8525<br />

TSI,8386A<br />

Ultra fine particle<br />

measurement<br />

Multifunction air quality<br />

meter<br />

TSI,8551 Indoor air quality monitor<br />

TSI,8554<br />

(multi-function)<br />

YES,205-5<br />

Multifunction air quality<br />

logger<br />

TES,645-1<br />

TES,645-2<br />

60 5~95<br />

50 5~95 500 5,000<br />

0.01 ~ 5x10 5 particles/cm 3<br />

0.02~1µ<br />

Logging<br />

TSI,8520-1 Outdoor enclosure<br />

Logging<br />

Logging, Wet bulb<br />

Dew point, Differential pressure<br />

Logging<br />

RS232C/Software<br />

50 5~95 200 10,000 300 Logging<br />

Humidity & dewpoint meter 120 2~98 Robust stainless probe<br />

CAS,MICROTHERM Area heat stress monitor * *<br />

Portable Smoke Generating Machine<br />

CSS,COLT4 AU<br />

portable smoke generator with variable smoke emission rate. Suitable for<br />

air flow visualisation, HVAC ductwork leak-testing, fire training and general<br />

work. pump-free operation with smoke fluid supplied from consumable<br />

aerosol cans or refillable containers [pump supplied for pressurisation].<br />

Manual or continuous operation and off-power facility. Maximum output 31<br />

cubic meters/min at 1.5m visibility. Operation for 18min from one can at<br />

maximum capacity.<br />

Airflow EDM2500 Electronic Manometer 0~2500 Pa<br />

AIR,EDM2500 AU/NZ<br />

pressure ranges 125, 500 & 2,500pa. Air velocity measurement using pitotstatic<br />

tube with ranges 14 & 28m/s. Supplied complete with pitot static tube,<br />

balancing valve, and tubing. Fitted with 1mA fsd recorder output. battery<br />

operated.<br />

Airflow DM2 Medium Pressure Manometer<br />

AIR,DM2 NZ<br />

Handheld medium pressure digital manometer. Suitable for positive,<br />

negative and differential pressure measuements. Displays readings in mBar,<br />

kpa & psi. Ranges are ±2,000mbar, 200kpa & 29.99psi. Resolution is 1 or<br />

0.1mbar & 0.1 or 0.01kpa. Accuracy on all ranges is 0.5% of reading. Serial<br />

interface for uploading stored results. Maximum stored readings during<br />

logging is 700. Analogue output of ±1V at 0.5mV per mbar.<br />

WBGT index, RH + Dewpoint<br />

*Air temp to 60º, Wet temp to 40º<br />

Globe temp to 120º<br />

> NEW<br />

TSI 8710 DP-CALC Differential Micro-Manometer<br />

TSI,8710 AU<br />

Micro-manometer for static or differential pressure, velocity, volumetric<br />

flow, atmospheric pressure and temperature. With statistical analysis,<br />

density correction, K factor and automatic actual/standard flow calculation.<br />

Differential pressure range ±3735pa. Velocity display to 78m/s (range<br />

depends on probe). Supplied with static tip, Pitot tube, velocity matrix and<br />

temperature probe. Datalogging (1,000 point) with RS232C interface and<br />

software. Rechargeable cells or AC adaptor.<br />

> NEW<br />

TSI 8705 DP-CALC Differential Micro-Manometer<br />

TSI,8705 AU<br />

Differential micro-manometer measuring differential pressure, velocity,<br />

average, volumetric flow, maximum and minimum. With static pressure<br />

calculations, density correction and K factor. pressure range -1245~3735pa.<br />

Velocity range 1.27~78.5m/s. Supplied with 200~980mm telescopic pitot<br />

tube. Datalogging (1000 point) with RS232C interface and software. Battery<br />

powered.