Megger BM21 500V/1/2/5kV Insulation Test Set<br />

MEG,bM21 AU<br />

Test voltages 25~5,000V in 25V steps. Insulation range to 1TΩ at 500V,<br />

5TΩ at 5kV. AC/dc voltage measurement 50V~1kV. Leakage current<br />

measurement. Capacitance measurement at end of test. Automatic<br />

discharge of capacitance. In-built test timer. Insulation burn mode - short<br />

circuit current 1mA nominal. battery life 8h, in-built charger for charging<br />

from mains or 12V dc.<br />

AVO/Megger BM11D Analogue/Digital 5kV Insulation Tester<br />

MEG,bM11D AU/MY<br />

Test voltages 500V, 1kV, 2.5kV and 5kV. Insulation range 10kΩ~500GΩ<br />

digital. AC/dc voltage measurement 50V~1kV. Timer 0~60min. Automatic<br />

discharge of capacitance. battery life 8h, in-built charger for charging from<br />

mains or 12V dc.<br />

Megger BM25 Insulation Tester<br />

MEG,bM25 AU/NZ<br />

Five kV insulation tester which is battery-powered, housed in a rugged case<br />

and has a large, analogue/digital LCD. A built-in timer makes both spot<br />

tests and polarisation Index (pI) testing easier to carry out. pre-set standard<br />

test voltages at 500V, 1, 2.5 & 5kV with variable test voltage in 25V steps.<br />

Displays capacitance at the end of a test to 10µF. Performs automatic PI,<br />

Step Voltage and Dielectric Discharge tests as well as providing an optically<br />

isolated RS232 port for downloading results during a test. Short circuit<br />

current: nominal 1.8mA, max 2mA. battery life: typically 8h.<br />

Megger CM500 Multifunction Installation Tester<br />

MEG,CM500 AU/NZ<br />

Combines the function of several instruments. Non-tripping loop test for<br />

tests on RCD protected circuits. RCD ramp test features actual tripping<br />

current. Functions are insulation, continuity, loop testing, RCD tests, voltage<br />

& frequency measurement. Phase indication, outlet polarity indication.<br />

Stores approximately 750 test results in memory for uploading to PC.<br />

> NEW<br />

Megger RCDT330 Residual Current Device Tester<br />

MEG,RCDT330 AU<br />

Tests standard, dc, selection and programmable RCDs. Ramp testing. Auto<br />

(remote) testing. 3ph safe. Enables testing on 110V centre tapped supplied.<br />

performs 1/21, 1xI & 50xI tests on RCDs rated at 10mA, 30mA, 100mA,<br />

300mA, 500mA & 1000mA on general and selective (time delayed) RCDs.<br />

Tough rubber armoured case with built-in cover. Weatherproof to Ip54. USb<br />

interface for downloading test result.<br />

LEM Saturn Insulation Tester<br />

LEM,SATURNISO AU<br />

Test voltages 50~1,000V in steps of 10V. Max range 30GΩ. Measures<br />

ac/dc voltage to 600V, resistance to 30kΩ. Digital and analogue display.<br />

Battery operated.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

inSulatiOn/cOnditiOn/reSiStance teSterS<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

Megger CBT2 Earth Leakage Breaker Tester<br />

MEG,CbT2 AU<br />

Residual current device (RCD)/safety switch, circuit breaker tester. Twelve<br />

ranges from 6~500mA. Displays tripping time in ms.<br />

Metrel MI 2121 AUS Advanced RCD Tester<br />

MET,MI2121AUS AU<br />

Exceeds all requirements of AS/NZS3760:2003. Stores up to 500 tests.<br />

Interface RS232 Software.<br />

Megger BT51 Low Resistance Ohmmeter<br />

MEG,bT51 AU<br />

Uses 4 terminal method with helical duplex dual pronged probes. Test<br />

current 2A nominal at 2Ω. Ranges 2, resolution 1mΩ, 20mΩ, resolution<br />

10µΩ. Accuracy at 0~500C, ±1% of reading, ±2digits. Display LED 3½<br />

digit. Power supply internal NiCd rechargeable batteries, typically around<br />

2,000 tests at 5s duration. Re-charge time around 10h with 240Vac mains<br />

power. Nett weight 45kgs.<br />

Megger LT6 Digital Loop Tester<br />

MEG,LT6 AU<br />

Earth fault loop impedance tester 20Ω range 0.01Ω resolution, 2kΩ range<br />

1Ω resolution. Single & 3ph systems can be tested. Used with MEG,CbT2<br />

to test compliance to AS2381.1 (electrical wiring for hazardous areas).<br />

Tests automatically when connection to circuit is made. Neons indicate fault<br />

conditions.<br />

Megger MFT1502 Combined Insulation, Loop & RCD Tester<br />

MEG,MFT1502 AU<br />

Tests fixed wiring in accordance with International and National Wiring<br />

Standards. Display digital/analogue arc LCD. Voltage measurement<br />

automatic selection ac or dc up to 270V. Continuity testing 200mA from<br />

0.01~99.9Ω, automatic continuity testing commences the moment the test<br />

probes touch the circuit to be tested. Audible tone to confirm test. Safety<br />

check for presence of a voltage. Variable buzzer threshold selectable from<br />

2~100Ω in 6 steps. Insulation testing 250, 500V & 1kV. Safety lockout<br />

at voltages greater than 55V. Auto discharge facility safely discharges all<br />

circuits after insulation test. Low current loop test, a 3-wire non-tripping<br />

0.01Ω loop test designed to prevent RCD tripping. High current loop test<br />

at 25A provides a fast test where no RCD is fitted. Supply voltage and<br />

polarity indication at 55V~280V, 45Hz~65Hz phase to phase. phase~phase,<br />

phase~neutral and phase~earth loop tests are possible. Loop measurements<br />

from 55V~480V. prospective short~circuit current (pSC), a high current loop<br />

test, is provided for rapid measurement of loop currents, both at the socket<br />

outlet and distribution board. Ranges from 1A~19.9kA with a resolution of 1,<br />

10 & 100A depending on range auto-ranging. RCD testing 10mA~1000mA<br />

with both 0 & 180O phase angle. RCD ramp test measures the RCD trip<br />

current. Displays actual trip current on all RCD ranges instead of trip time.<br />

LED torch in illuminated probe for low light level areas. Ip54<br />

ELEC<strong>TR</strong>ICAL POWER<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 45