ELEC<strong>TR</strong>ICAL POWER<br />

46<br />

inSulatiOn/cOnditiOn/reSiStance teSterS<br />

Kikisui TOS-5051 5kV ac/dc Hi-Pot Tester<br />

KIK,TOS-5051 AU<br />

High voltage ac/dc insulation test set. Ranges 0~2.5kV & 0~5kV. Max<br />

output ac 100mA, dc 10mA. pass/fail comparator included.<br />

> NEW<br />

Megger Digital Earth Test Clamp<br />

MEG,DET20C AU<br />

Measures ground resistance from 25mΩ~1550Ω . Measures ground<br />

leakage current from 0.2mA~35A. Automatic self calibration. Auto ranging.<br />

High and low alarms. Large memory. Download to Megger Download<br />

Manager. Measures earth resistance in installations such as buildings,<br />

pylons and RF transmitter sites. Use for the inspection and verification of<br />

lightning protection systems. Large jaw opening.<br />

Megger Det5/3R Ground Resistance Tester<br />

MEG,DET5/3R AU<br />

MEG,DET5 NZ<br />

Checks resistance of electrical systems including soil resistivity. Measures<br />

resistance from 0.01~19,999Ω in 4 ranges. LCD 3½ digit display. Operating<br />

frequency 128Hz. Complete with earth testing kit including spikes and wire.<br />

3M Model 701 Micro-ohm ESD Surface Tester<br />

3M,701 AU<br />

Tester for static control surfaces, table mats, field service kits, floor coverings,<br />

etc. Test voltages 10 & 100V. Resistance range 0~100GΩ.<br />

Baur DAP75 Insulating Oil Tester<br />

bAU,DpA75 AU<br />

Output voltage 0~75kV rms. Selectable programmes to international<br />

standards. Integral printer. RS232 interface.<br />

AVO OTS60PB Transformer Oil Tester<br />

AVO,OTS60pb AU<br />

Test voltage 60kV max at 61.8Hz. Fully automatic operation. Rechargeable<br />

battery operation. RS232C interface.<br />

BJM All-Test III Motor, Coil and Winding Tester<br />

bJM,ALL-TEST3 AU<br />

Tester for single or polyphase ac motors, generators, transformers or<br />

dc motors. Use to test any motor, coil or winding to determine insulation<br />

condition between windings, windings and frame, open circuits. Also<br />

measure phase balance and angle. Impedance (z) 5~1,000Ω. Inductance<br />

(L) 0.35mH~1.6H. Capacitance (C) 100mF~50nF. power factor (Fi) 0~90O .<br />

Insulation 0~20MΩ @ 1kV. Frequency range 100, 300, 850Hz & 2.4kHz<br />

(times 2).<br />

BJM All-Test IV PRO 2000<br />

bJM,ALL-TEST-4 AU<br />

Tests single or polyphase ac motors, generators, transformers or dc motors.<br />

Use to test any motor, coil or winding to determine insulation condition<br />

between windings, windings and frame, open circuits. Measure phase<br />

balance and angle. Impedance (z) 5Ω~1kΩ. Inductance (L) 0.35mH~1.6H.<br />

Capacitance (C) 100mF~50nF. power factor (Fi) 0-90 O . Insulation: 0~20MΩ<br />

@ 1kV. Frequency range 100, 300, 850Hz & 2.4kHz (times 2).<br />

LEM Saturn GEO Easy Earth Tester<br />

LEM,SATURN GEO EASY AU<br />

Waterproof instrument (rubber protective cover IP56). Measures earth<br />

resistance, 3 or 4 pole. Soil resistivity. Measures resistance from 0~20kΩ.<br />

Display 4 digit back light 25mm LCD. Operating frequency 128Hz. Single<br />

button user interface. Complete with earth testing kit including 4 stakes, 3<br />

reeled cables, clips and carry case.<br />

LEM Saturn GEO X Earth/Soil Resistance Tester<br />

LEM,SATURN-GEO-x AU<br />

Automatically tests earth/soil resistance 3, 4 pole and stakeless with CT.<br />

Optimise output frequency (manual or automatic) 0.001~300kΩ at 20 &<br />

48Vac, frequency 94, 205, 111, & 128Hz. Displays all measuring results<br />

for as long as desired. programmable limits. Optical and audible over-limit<br />

warning. Splash-proof case Ip56 (outdoor application). Measurements with<br />

current clamps: selective, stakeless. Resistance measurements with 250mA<br />

short circuit current. Output of measured values via interface on printer or<br />

PC.<br />

LEM Saturn 100plus Safety Tester<br />

LEM,SATURN100+ AU<br />

Confirms correct operation of RCD protection, resistance of all aspects of<br />

protective earthing systems, loop impedance, line-neutral polarity, predictive<br />

short circuit current, phase sequence and voltage. RCD current 10mA~1A.<br />

Tripping time 1~500ms. Tripping current measurement with intelligent ramp.<br />

Fault voltage 0.1~99.9V. Loop and earthing resistance 0.15W~10kW. Earth<br />

electrode voltage (SEV 3569) up to 199V. Short-circuit current 1A~9.99kA.<br />

Loop/line internal resistance RLOOp 0.07~200W. Nominal line voltages<br />

100~435V. battery-saving, automatic switch-off, typical battery service-life<br />

3,500 insulation measurements.<br />

Multi-amp MET-2 Clamp-On Earth Tester<br />

MUL,MET-2 NZ<br />

Clamp-on earth tester 0.01~300Ω. Measures earth resistance by using 2<br />

clamp CTs without disconnecting the earth conductor. Measures dc loop<br />

resistance without any influence from other conductors.<br />

Seaward Europa Advanced Portable Appliance Tester<br />

SEW,EUROpA pAT AU<br />

Records results, compliant with AS/NZS 3760: 2001/2003 can be printed as a<br />

certificate using the serial/parallel adaptor. bar-code reader included. Earth<br />

continuity output current 100mA~25A ac. Range 0.01~20Ω. Accuracy ±5%<br />

of reading ±2 digit. Insulation test range, 100kΩ~100MΩ. Test voltage,<br />

250, 500Vdc. Resolution 0.01MΩ. Includes plug adaptor to test, EpODs<br />

and extension leads (IEC - IEC and Australian).