DATA ACQUISITION & RECORDING<br />

72<br />

data lOggerS<br />

Hioki 8421-01 16 Channel Data Logger with Colour Display<br />

HIO,8421-01 AU<br />

Sixteen analogue, 4 pulse input channels data logger with colour display,<br />

pCMCIA card slot, LAN interface built in, TCp/Ip communication supports<br />

real time PC logging, FTP, SMTP and HTTP. Signal inputs 100mVdc, 1Vdc,<br />

10Vdc, 60Vdc, 1~5Vdc fs. Thermocouples K,E, J, T, N, W (WRe5~26) R,<br />

S, b, -100~100OC, -200~500OC, -200~2,000OC, RTD pt100 -200~800OC.<br />

Pulse input, accumulation 50,000 counts fs, 500,000 counts fs, 5M counts<br />

fs, 100M counts fs, 2,500M counts fs. Rotation 5,000/n (r/s) fs. Recording<br />

interval is selectable from 100, 200, 500ms, 1, 2, 5, 10, 20, 30s, 1, 2 &<br />

5min. Max sampling rate is dependent upon type of input signal. Internal<br />

Memory 8Mb, 256Mb Flashcard, 9334 logger communicator software, 9642<br />

LAN cable, 9641 pulse signal input cable all supplied.<br />

Hioki 8421-51 16 Channel Data Logger with Colour Display<br />

HIO,8421-51 AU<br />

Sixteen Analogue, 4 pulse input channels data logger with colour display,<br />

pCMCIA card slot, LAN interface built in, TCp/Ip communication supports<br />

real time pC logging, FTp, SMTp and HTTp. Signal inputs- 100 mVdc, 1Vdc,<br />

10 Vdc, 60Vdc, 1-5Vdc f.s. Thermocouples K,E, J, T, N, W (WRe5-26) R,<br />

S, b, -100~100OC, -200~500OC, -200~2000OC, RTD pt100 -200~800OC.<br />

Pulse input, accumulation 50,000C f.s, 500,000C f.s, 5MC f.s, 100MC f.s,<br />

2,500MC f.s. Rotation 5,000/n (r/s) f.s. Recording interval selectable from<br />

100ms, 200ms, 500ms, 1s, 2s, 5s, 10s, 20s, 30s, 1min, 2min, 5min. Max<br />

sampling rate is dependent upon type of input signal. Internal Memory 16MW,<br />

512Mb pCMCIA FLASH card, 9334 Logger Communicator software, 9642<br />

LAN cable, 9641 pulse signal input cable all supplied. Improved common<br />

mode rejection- 100db or better when 50/60Hz, 140db or better when 50Hz,<br />

using ch1 to ch16, interval 5s, digital filter 50Hz selected. Faster sampling<br />

when using Pt100, improved temperature characteristics.<br />

Hioki 8422-51 32 Channel Data Logger Logger<br />

HIO,8422-51 AU<br />

Thirty two analogue, 4 pulse input channels data logger with colour display,<br />

pCMCIA card slot, LAN interface built in, TCp/Ip communication supports<br />

real time pC logging, FTp, SMTp and HTTp. Signal inputs: 100mV, 1, 10 &<br />

60Vdc, 1~5Vdc fs. Thermocouples K,E, J, T, N, W (WRe5-26) R, S, b, -100<br />

~100OC, -200~500OC, -200~2,000OC. pulse input, accumulation 50,000<br />

counts fs, 500,000 counts fs, 5M counts fs, 100M counts fs & 2,500M counts<br />

fs. Rotation 5,000/n (r/s) fs. Recording interval is selectable from 100, 200,<br />

500ms, 1, 2, 5, 10, 20, 30s, 1, 2 & 5min. Max sampling rate is dependent<br />

upon type of input signal. Internal Memory 8Mb, 512Mb pCMCIA FLASH<br />

card, 9334 Logger Communicator software, 9642 LAN cable, 9641 pulse<br />

signal input cable all supplied.<br />

Yokogawa MV200 Twenty Channel Logger<br />

YEW,MV200 NZ<br />

Twenty channel voltage, RTD and thermocouple logger. Color LCD display<br />

10.4” TFT, removable pCMCIA ATA flash memory card. Supports data<br />

collection over ethernet networks. Supplied with RJ-45 cable and standard<br />

software.<br />

Yokogawa Data Logger for PC Acquisition<br />

YEW,DA100-40CH AU<br />

pC based datalogger with dc supply. Channels 40, 50V max input 0.05%<br />

basic accuracy. Accepts RTD and TC inputs. Must be used in conjunction<br />

with a PC includes analysis software. Scan rate 2s.<br />

Yokogawa 2423A Six Channel Logger<br />

YEW,2423A17 NZ<br />

Portable voltage and thermometer logger. Ranges are 10, 1 & 0.1V. Type<br />

K, E, J, T, R, S, b, L, U thermocouples. Memory stores 14,000 data points.<br />

Min logging interval is 10s. Large LCD display, analogue and RS232 output.<br />

Supplied with software for uploading data to CSV or TxT format.<br />

> NEW Hioki 3632-20 Temperature Logger with Internal<br />

Sensor Only<br />

HIO,3632-20 AU<br />

Temperature logger (1 channel) includes 1 x RS232C & 1 x USb<br />

communication base, utility software, RS232C and USb interface cables.<br />

Temperature range -20~+70ºC. Accuracy -20~-0.1ºC +/-1.0ºC. 0~35ºC +/-<br />

0.5ºC, 35.1~70ºC +/-1.0ºC. Internal thermistor sensor, water resilience Ip67.<br />

Built in LCD.<br />

Hioki 3641-20 Temperature/Humidity Logger with RS-232C &<br />

USB<br />

HIO,3641-20 AU/MY<br />

Includes 1 x RS232C & 1 x USb communication base, utility software,<br />

RS232C & USb interface cables. Temperature range -40~85OC, humidity<br />

range 0%~100%RH. Accuracy temperature -40~-0.1OC ±1, 0~35OC ±0.5,<br />

35.1~70OC ±1 & 70.1~85OC ±2. Humidity typical between ±5~±10%RH<br />

depends on temperature and humidity range.<br />

Hioki 3641-20-Kit of 8 Temperature & Humidity Loggers<br />

HIO,3641-20-KIT AU<br />

Kit of 8 x temperature and humidity loggers. Includes 1 x RS232C and 1<br />

x USb communication base, utility software, RS232C and USb interface<br />

cables. Temperature range -40OC~85OC, humidity range 0.0%RH to 100%<br />

RH. Accuracy: Temperature -40~-0.1OC +/- 1.0OC , 0.0~35OC +/- 0.5OC,<br />

35.1~70OC +/- 1OC, 70.1~85OC +/- 2OC. Humidity typical between +/-5 to<br />

+/-10% depends on temperature and humidity range. 8000 data points x 2<br />

channels, recording interval 2,5,10,15,20,30 sec,1,2,5,10,15 ,20,30,60 min.<br />

Fourier Microlog Temp/Hum Logger Kit with Wireless Cradles<br />

FOU,MICROLOG-KIT AU<br />

Set of 5 temperature and humidity loggers mounted in RF transmitter<br />

cradles, one receiver for PC. Transmission range up to 300m or RS232C<br />

& USb interface also included if direct connection to pC for down loading<br />

required. Temperature range -30~50OC, accuracy ±1O, 0~100%RH<br />

accuracy ±3%RH, 2 digit LCD, memory capacity 16,000 data points<br />

between 2 channels. User defined sampling rate from 10s~2h. MicroLog<br />

Plus management control software included to control and monitor all the<br />

loggers remotely on PC within transmission range.<br />

Escort Temperature Humidity Logger Set of 10<br />

ESC,HUM/T-KIT AU<br />

ESC,HUM-KIT NZ<br />

Includes software and communication base for down loading of data from<br />

loggers to a PC. Data presented in table or graph form. Max sample rate<br />

1min.