TSI 8704 DPCALC Micro Manometer<br />

TSI,8704 AU<br />

Measures differential pressure, velocity, average, volumetric flow, max & min.<br />

With static pressure calculations, density correction and K factor. Pressure<br />

range -1245~3735pa. Velocity range 1.25~78.5m/s. Extendable pitot tube<br />

20~980mm. Datalogging 500 point with RS232C interface and software.<br />

DPM TT370S Digital Manometer<br />

DPM,TT370S NZ<br />

Digital micromanometer with an extendable pitot tube kit. Dp ranges are<br />

199.9pa, 1,999pa & 7kpa. Velocity range with pitot kit is 1.2~100m/s. Dp<br />

accuracy is 1% of reading +2 counts. Recorder output of 1mV per count.<br />

DPM TT570CL Digital Manometer NATA Certification<br />

DpM,TT570CL-NATA NZ<br />

Digital micromanometer with an extendable pitot tube kit. Dp ranges are<br />

199.9pa, 1,999pa & 7kpa. Velocity range with pitot kit is 1.2~100m/s.<br />

Dp accuracy is 1% of reading +2 counts. built-in data logger holds 1,400<br />

readings.<br />

Druck DP1705 Manometer 0~20 kPa<br />

DRU,DpI705 AU<br />

Handheld digital manometer range 0~20kpa, accuracy 0.2 %. Displays all<br />

common engineering units.<br />

Shortridge ADM-860 Electronic Manometer<br />

SHO,ADM-860 AU/MY<br />

Electronic micro manometer for air balance and similar applications.<br />

Measures differential pressure, air velocity and temperature. Differential<br />

pressure range 0.0025~1,500mm wg. Velocity range 7.5~3,000m/min<br />

(750m/min with velgrid). Memory 100 point with sum and average.<br />

Accessories include pitot tube and 16 point velgrid for face velocity work<br />

including exhaust hoods, clean room outlets, and large filters or coils.<br />

Airflow 36 Pitot Tube<br />

AIR,pITOT-36 AU<br />

pitot tube (36”) for use with manometers and micro manometers.<br />

Kurz 2443 Air Velocity Meter<br />

KUR,2443-24 AU<br />

portable air velocity meter and flow-computer. Working velocity range<br />

0~12,000 sf/m (60m/s) at pressures to approx 10bar (probe rated to 20bar).<br />

Temperature range -40~200OC with compensation. Selectable English<br />

or metric units for velocity or mass-flow. Thermal sensor probe 9.5mmØ<br />

x 330mm long with sensor-shield. Compression fitting and nylon ferrules<br />

for probe removal or position adjustment in tapped pipe. Suitable for use<br />

in ducts or pipes, min pipe 50mmØ approx. Calibrated for air and suitable<br />

for use with other non-hazardous gases. Recording of up to 1,500 data sets<br />

with time and date. Two analog 4~20mA outputs, and RS232C serial port for<br />

configuration upload and data download. Rechargeable NiMH batteries.<br />

TSI 8370 Accubalance Balometer<br />

TSI,8370 MY<br />

balometer including 5-hood kit and hard case. Flow range 15~1,000 litres/<br />

sec (50 to 3,500m3/hr) accuracy +/-5%, reading +/- 2.4 l/s (8.5m3/hr).<br />

Operating temp range 0-60OC. Weight (610 x 610mm hood) 3.4 kg hood<br />

provided 610 x610mm (standard), 610 x 1220mm, 305 x 1220mm, 305 x<br />

1525mm and 915 x 915mm.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

air flOW meaSurement/air quality<br />

TSI 8371 Accubalance Balometer<br />

TSI,8371 NZ<br />

Airflow hood 610 x 610mm. Measures air volume flowing through registers,<br />

diffusers, and grilles. Range is 15~1,000l/s, accuracy is ±5%. Temperature<br />

range is 0~60ºC. Sample and hold function displays reading of one sample.<br />

Automatic conversion between actual and standard flows when user initially<br />

inputs temperature and barometric pressure, variable time constant modes<br />

available for a steady display when measuring fluctuating flows, K factor<br />

function enables flexibility for measuring a variety of diffusers, back-lit display<br />

is easy to read in poor lighting conditions.<br />

TSI 8373 Balometer With Logging<br />

TSI,8373 AU<br />

Flow range 15~1,000L/s (50~3,500m3 /hr); accuracy ±5% [to ±2.4L/s].<br />

Operating temperature range 0~60OC. Includes 5 hood kit & hard case.<br />

Hoods provided 610 x 610mm (standard), 610 x 1,220mm, 305 x 1,220mm,<br />

305 x 1,525mm & 915 x 915mm.<br />

TSI 8375 Accubalance Modular Air Balancing<br />

TSI,8375 (NZ)<br />

Balometer with detachable micromanometer for air balancing applications.<br />

610 x 610mm air capture hood for measurements in the range 42~4,250m3/<br />

h with automatic compensation for barometric pressure and air temperature,<br />

450mm pitot probe (range 0.13~41m/s), 16-point velocity matrix probe<br />

(0.13~13m/s) and static pressure probes (differential pressure range<br />

±3,735pa with safe limit 37kpa, absolute pressure range 47~135kpa).<br />

Accuracy typically 2% for pressure, 3% for flow. Large, multi-line backlit<br />

LCD display for single or statistical readings with min, max and average of<br />

up to 1,000 values of each measured parameter. Manual result storage or<br />

automatic data logging up to 1,000 time/date stamped readings. RS232 port<br />

for data transfer to pC or serial printer, with cable and “LogDat” download<br />

software. Rechargeable with approx 12h operation, or ac adaptor.<br />

Shortridge CFM88-3 Electronic Balometer<br />

SHO,CFM88-3 AU<br />

Measures supply and exhaust flow in cfm and l/sec. Ranges 25~2500cfm<br />

supply and 25~1500cfm exhaust. Compensated for air density and back<br />

pressure. Hood sizes 600 x 600mm, 600 x 1,200mm & 300 x 1,200mm.<br />

Airflow AV2 100mmØ Anemometer with Volume display<br />

AIR,AV2 AU/NZ<br />

Vane anemometer with 900mm (35”) telescopic probe extension. Velocity<br />

measurement range 0.25~30m/s (50~6,000ft/min). Averaging mode<br />

available. Volume display based on duct or other area. Head operating<br />

range -10~70OC (lower limit of -30CC for short periods). Output 0~1V.<br />

Airflow AV2 100mmØ Anemometer NATA Certification<br />

AIR,AV2-NATA AU<br />

Specification as above but with NATA certification.<br />

Airflow AV6 100mmØ Anemometer with Volume<br />

AIR,AV6 NZ<br />

Vane anemometer 100mmØ with articulating extension handle. Measures<br />

velocity, volume flow and temperature. Vane head operating range is -<br />

10~70ºC, -30 possible for short periods. Accuracy is ±1% of reading +1<br />

digit. Resolution is 0.01 m/sec. Velocity range is 0.25~30m/s. RS-232C<br />

interface for data logging & real time data retrieval. Stores up to 99 readings<br />

of velocity & temperature. Analogue output of 0~1v.<br />

Schilknecht Mini Air 2 Vane Anemometer<br />

SCH,MINI-2 AU<br />

probe 22mmØ. Range 0.3~40m/s. Min, max & time averaging functions<br />

with 0~1V analog output.<br />

AIR CONDITIONING & AIR QUALITY - HVAC & IAQ<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 115