NEW<br />
CHK Gridsense PM40 Power Quality Analyser<br />
CHK,pM40pQA<br />
Weatherproof Ip65 field unit. Channels: 3V, 63-440V (isolated). 4 current<br />
0 to 3,000A (3ph and neutral) rms. Supplied with 4 flexible 3,000A clampon<br />
CTs (flexible CT length 600mm and Diameter 190mm). (In addition,<br />
clamp-on CTs of 3,000A, 1,000A for large conductors and 500A and 100A<br />
for neutral conductor current measurement are available.) Memory: 15 Mb.<br />
Inbuilt Graphic 128x64 bits LCD display, 7 rows x 20 characters. Records: V,<br />
A, pf, f(Hz), kVA, kVAr, kW, harmonics, Inter harmonics, voltage and current<br />
imbalance (THD and individual to 48th ) and Flicker. Total energy, tariffs,<br />
maximum demands, and transient and sub-cycle disturbances. Included<br />
software provides graphs and summaries to PC. Download files while<br />
logging USb interface. A pC using Windows 95, 98, NT4, WIN2000 or xp<br />
O/S, is required with the CHK powerView software to configure this unit<br />
before operating.<br />
pOWer analySerS & recOrderS<br />
GridSense CHK PM30 Plus 3 Phase Powermonic Logger/<br />
Logger<br />
CHK,pM30pLUS AU<br />
Weatherproof Ip65 field unit. Channels 3 voltage, 63-440V (isolated), 4<br />
current 0 to 3kA (3ph & neutral) rms. Supplied with 3 x flexible 3kA clampon<br />
CTs (flexible CT length 600mm & 190mmØ). Clamp-on CTs of 3kA,<br />
1kA for large conductors and 500A & 100A for neutral conductor current<br />
measurement are available. Memory 4 Mb. Inbuilt 2 line LCD display.<br />
Records V, A, pf, f(Hz), kVA, kVAr, kW, harmonics, (THD and individual to<br />
48th ). Total energy, tariffs, maximum demands, transient and sub-cycle<br />
disturbances. Software provides graphs and summaries to PC. Download<br />
files while logging via RS232 interface. pC using Win 95, 98, NT4, 2000,<br />
xp, O/S, is required with the CHK pOWERview software to configure this<br />
unit before operating.<br />
�������<br />
���������<br />
�������<br />
���������<br />
��������������������<br />
��������������������<br />
�����������������������������<br />
�����������������������������<br />
���������������<br />
���������������<br />
�������� ����<br />
the latest addition to the rugged, weatherproof and versatile<br />
powermonic range has ��� ��� ��� ���<br />
features including:<br />
• flicker monitoring<br />
• interharmonics<br />
• voltage unbalance<br />
• increased memory capacity (15mb)<br />
• larger lcd display<br />
• real-time data display<br />
• compliance to all iEc pq standards<br />
• high-speed usb data transfer<br />
Other features include:<br />
for more information visit - http://www.gridsense.net�<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
• tables & graphs of 3 phase v,a, pf,dpf, kw, kva, kvar, thd,<br />
harmonic phase angle, individual harmonics, interharmonics,<br />
frequency, all to iEc standards<br />
• total Energy & tariffs calculator<br />
• ability to capture motor starts, high speed rms & waveform<br />
disturbances<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
ELEC<strong>TR</strong>ICAL POWER<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 55