RENTAL SOLUTIONS GUIDE 2007 - TR Corporation
RENTAL SOLUTIONS GUIDE 2007 - TR Corporation
RENTAL SOLUTIONS GUIDE 2007 - TR Corporation
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Escort Analogue Adaptor<br />
ESC,ANALOGUE NZ<br />
Analogue adaptor for dc voltage and dc current inputs. Inputs: 0~20mA, 0~2<br />
VDC, 0~10Vdc.<br />
Escort Four Channel Temperature Logger<br />
ESC,4 ExT NZ<br />
Range -20~60OC. Resolution 0.3OC. Accuracy 0.5OC. Stores 30,000<br />
readings. Supplied with software, interface and 3m long temperature<br />
sensors.<br />
Escort Three Channel Low Temperature Logger<br />
ESC,3ExT-LO/SS NZ<br />
Range -40~40ºC, accuracy 0.5ºC, resolution 0.3ºC. Supplied with 3<br />
temperature sensors and software.<br />
Escort Internal Temperature Logger<br />
ESC,INT-LO NZ<br />
Single channel low temperature logger. Range -40~40ºC, resolution is 0.5ºC,<br />
accuracy is 0.3ºC. Can be immersed in liquid. Stores 24,000 readings.<br />
Supplied with software and serial interface for uploading data.<br />
Escort pH Adaptor<br />
ESC,pH-ADApTOR NZ<br />
Glass electrode type pH adaptor probe. Range 0~14pH, resolution 0.015pH.<br />
User calibration via offset and slope adjustment screws. Supplied with 10m<br />
temperature compensation probe. WARNING!! Do not use the electrode in<br />
perchlorate, silver, sulphide or any hydrofluoric solutions containing more<br />
than 1M acid or base, or at temperatures more than 50ºC. Use at high<br />
temperatures may shorten the life of the electrode.<br />
Escort Autoclave Logger<br />
ESC,AUTOCLAVE NZ<br />
Temperature logger suitable for use in autoclave sterilizers. Temperature<br />
range is 25~150ºC, resolution: 0.5ºC, accuracy: ±0.5ºC. Rated to 150ºC<br />
for 30min or 125ºC for indefinite. Maximum of 60min endurance for dry<br />
heat oven @ 150ºC. Stainless steel body with 1 external sensor, stores<br />
2000 readings in its memory. IP68 rated to 5bar. Supplied with calibration<br />
certificate, software and serial interface for programing & uploading.<br />
data lOggerS<br />
Tiny Tag One Channel 0~20mA Current Input Logger<br />
TIN,TGpR-0804 AU<br />
Logger 4~20mA single channel. Readings 15,900. Re-scalable Ip68 78w x<br />
50d x 34hmm. Two level alarm leds. Accuracy 0.6% 0.1mA.<br />
Tiny Tag TGPR~0704~10Vdc Data Logger<br />
TIN,TGpR-0704-10VDC AU<br />
Single channel 0~10Vdc logger , 8 bit A to D resolution. Stores 15,900<br />
readings. 2 alarms with red indicator LED. Reading interval from 1s~10d.<br />
Range: 0~10Vdc, max input 14V, accuracy ±40mV, ±1% rdg, 400kΩ<br />
impedance. Battery operated.<br />
Tiny Tag TGPR~0704~2.5Vdc Data Logger<br />
TIN,TGpR-0704-2.5V AU<br />
Single channel 0~2.5V logger, 8 bit A to D resolution. Stores 15,900<br />
readings. 2 alarms with red indicator LED. Reading interval from 1s~10d.<br />
Range 0~2.5V range, max input 3.5V, accuracy ±10mV. battery operated.<br />
Testo 177-H1 Logger with Display<br />
TES,177-H1 MY<br />
parameters: Humidity/Temp/Dew point. Sensors: Humidity Sensor/<br />
NTC(internal). No of Channels: 4 CH. Measuring Range: 0~100%RH &<br />
-20~+70 celcius(internal). Memory: 48,000 readings.<br />
Testo 177-T4 Logger with Display<br />
TES,177-T4 MY<br />
parameters: Temperature(C/F). Sensors: Thermocouple Type-K. No of<br />
Channels: 4 CH(external). Measuring Range: -100~+1000 celcius(external).<br />
Memory: 48,000 readings<br />
inStrumentatiOn amplifierS<br />
Vishay 2100 Eight Channel Instrument Amplifier<br />
VIS,2100 AU<br />
Eight channel signal conditioner/amplifier system comprising 4 dual amplifiers with power supply, digital output display and rack frame. Accepts low level<br />
signals and conditions and amplifies them to drive recorders. bridge balancing for quarter (120 & 350Ω), half & full bridge (50~1kΩ). Quarter bridge dummy<br />
resistors provided. Gain 100~2100. bandwidth dc ~5kHz at 0.5db, 13kHz at 3db. Output ±10V @ 30mA, 50mA into 150Ω, 100 mA into 15Ω. Type 2130<br />
digital readout can be switched to each output in turn and also to an external source. Ranges ±1,999mV & 19,999mV.<br />
Yokogawa ORP1200 8 Channel Memory Recorders<br />
YEW,ORp1200 AU/MY<br />
In-built waveform display. Input ranges 100mV~500V. Max input voltage<br />
is 500V peak or 350V rms ac. Memory 32k per channel, may be combined<br />
for 2 channel 128k operation. Memory may be divided into 16 blocks of<br />
2k. 128k memory at 1kHz sampling (20 points of 50Hz cycle) gives 128s<br />
storage. Real time recording 10mm/hr~100mm/s. Real time recorder with<br />
memory trigger facility. 4 triggers including high, low, rise, fall, with and/or<br />
facility. x-Y operation with up to 4 channels. Memory card facility for storing<br />
memory dumps and setups. Memory card not included.<br />
Yokogawa ORM1300 16 Analogue Channel Memory Recorders<br />
YEW,ORM1300 AU<br />
Similar to YEW,ORM1200 except it has 16 analog channels rather than 8.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
memOry recOrderS<br />
Yokogawa ORM1200 8 Channel Memory Recorders<br />
YEW,ORM1200 AU<br />
Similar to YEW,ORp1200 except it has 128K RAM per channel (ie. 512K<br />
when used as a 2 channel recorder) includes FDD.<br />
Yokogawa DL708 8 Channel Recorder/Digital Scope<br />
YEW,DL708E MY<br />
Eight channels 10M/s sampling 10 bit 8M word of memory, 1.2Gb HDD<br />
(100k/s sampling continuously to disk). In-built printer, FDD, RS232, GpIb<br />
and VGA. Input ranges 5mV/div~200V/div . 800V isolated input capability<br />
(using x10 probes). Input filters, FFT, color display, measurement of 26<br />
waveform parameters. Simple and advanced trigger including a window<br />
trigger.<br />
DATA ACQUISITION & RECORDING<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 73