01.12.2012 Views

RENTAL SOLUTIONS GUIDE 2007 - TR Corporation

RENTAL SOLUTIONS GUIDE 2007 - TR Corporation

RENTAL SOLUTIONS GUIDE 2007 - TR Corporation

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Escort Analogue Adaptor<br />

ESC,ANALOGUE NZ<br />

Analogue adaptor for dc voltage and dc current inputs. Inputs: 0~20mA, 0~2<br />

VDC, 0~10Vdc.<br />

Escort Four Channel Temperature Logger<br />

ESC,4 ExT NZ<br />

Range -20~60OC. Resolution 0.3OC. Accuracy 0.5OC. Stores 30,000<br />

readings. Supplied with software, interface and 3m long temperature<br />

sensors.<br />

Escort Three Channel Low Temperature Logger<br />

ESC,3ExT-LO/SS NZ<br />

Range -40~40ºC, accuracy 0.5ºC, resolution 0.3ºC. Supplied with 3<br />

temperature sensors and software.<br />

Escort Internal Temperature Logger<br />

ESC,INT-LO NZ<br />

Single channel low temperature logger. Range -40~40ºC, resolution is 0.5ºC,<br />

accuracy is 0.3ºC. Can be immersed in liquid. Stores 24,000 readings.<br />

Supplied with software and serial interface for uploading data.<br />

Escort pH Adaptor<br />

ESC,pH-ADApTOR NZ<br />

Glass electrode type pH adaptor probe. Range 0~14pH, resolution 0.015pH.<br />

User calibration via offset and slope adjustment screws. Supplied with 10m<br />

temperature compensation probe. WARNING!! Do not use the electrode in<br />

perchlorate, silver, sulphide or any hydrofluoric solutions containing more<br />

than 1M acid or base, or at temperatures more than 50ºC. Use at high<br />

temperatures may shorten the life of the electrode.<br />

Escort Autoclave Logger<br />

ESC,AUTOCLAVE NZ<br />

Temperature logger suitable for use in autoclave sterilizers. Temperature<br />

range is 25~150ºC, resolution: 0.5ºC, accuracy: ±0.5ºC. Rated to 150ºC<br />

for 30min or 125ºC for indefinite. Maximum of 60min endurance for dry<br />

heat oven @ 150ºC. Stainless steel body with 1 external sensor, stores<br />

2000 readings in its memory. IP68 rated to 5bar. Supplied with calibration<br />

certificate, software and serial interface for programing & uploading.<br />

data lOggerS<br />

Tiny Tag One Channel 0~20mA Current Input Logger<br />

TIN,TGpR-0804 AU<br />

Logger 4~20mA single channel. Readings 15,900. Re-scalable Ip68 78w x<br />

50d x 34hmm. Two level alarm leds. Accuracy 0.6% 0.1mA.<br />

Tiny Tag TGPR~0704~10Vdc Data Logger<br />

TIN,TGpR-0704-10VDC AU<br />

Single channel 0~10Vdc logger , 8 bit A to D resolution. Stores 15,900<br />

readings. 2 alarms with red indicator LED. Reading interval from 1s~10d.<br />

Range: 0~10Vdc, max input 14V, accuracy ±40mV, ±1% rdg, 400kΩ<br />

impedance. Battery operated.<br />

Tiny Tag TGPR~0704~2.5Vdc Data Logger<br />

TIN,TGpR-0704-2.5V AU<br />

Single channel 0~2.5V logger, 8 bit A to D resolution. Stores 15,900<br />

readings. 2 alarms with red indicator LED. Reading interval from 1s~10d.<br />

Range 0~2.5V range, max input 3.5V, accuracy ±10mV. battery operated.<br />

Testo 177-H1 Logger with Display<br />

TES,177-H1 MY<br />

parameters: Humidity/Temp/Dew point. Sensors: Humidity Sensor/<br />

NTC(internal). No of Channels: 4 CH. Measuring Range: 0~100%RH &<br />

-20~+70 celcius(internal). Memory: 48,000 readings.<br />

Testo 177-T4 Logger with Display<br />

TES,177-T4 MY<br />

parameters: Temperature(C/F). Sensors: Thermocouple Type-K. No of<br />

Channels: 4 CH(external). Measuring Range: -100~+1000 celcius(external).<br />

Memory: 48,000 readings<br />

inStrumentatiOn amplifierS<br />

Vishay 2100 Eight Channel Instrument Amplifier<br />

VIS,2100 AU<br />

Eight channel signal conditioner/amplifier system comprising 4 dual amplifiers with power supply, digital output display and rack frame. Accepts low level<br />

signals and conditions and amplifies them to drive recorders. bridge balancing for quarter (120 & 350Ω), half & full bridge (50~1kΩ). Quarter bridge dummy<br />

resistors provided. Gain 100~2100. bandwidth dc ~5kHz at 0.5db, 13kHz at 3db. Output ±10V @ 30mA, 50mA into 150Ω, 100 mA into 15Ω. Type 2130<br />

digital readout can be switched to each output in turn and also to an external source. Ranges ±1,999mV & 19,999mV.<br />

Yokogawa ORP1200 8 Channel Memory Recorders<br />

YEW,ORp1200 AU/MY<br />

In-built waveform display. Input ranges 100mV~500V. Max input voltage<br />

is 500V peak or 350V rms ac. Memory 32k per channel, may be combined<br />

for 2 channel 128k operation. Memory may be divided into 16 blocks of<br />

2k. 128k memory at 1kHz sampling (20 points of 50Hz cycle) gives 128s<br />

storage. Real time recording 10mm/hr~100mm/s. Real time recorder with<br />

memory trigger facility. 4 triggers including high, low, rise, fall, with and/or<br />

facility. x-Y operation with up to 4 channels. Memory card facility for storing<br />

memory dumps and setups. Memory card not included.<br />

Yokogawa ORM1300 16 Analogue Channel Memory Recorders<br />

YEW,ORM1300 AU<br />

Similar to YEW,ORM1200 except it has 16 analog channels rather than 8.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

memOry recOrderS<br />

Yokogawa ORM1200 8 Channel Memory Recorders<br />

YEW,ORM1200 AU<br />

Similar to YEW,ORp1200 except it has 128K RAM per channel (ie. 512K<br />

when used as a 2 channel recorder) includes FDD.<br />

Yokogawa DL708 8 Channel Recorder/Digital Scope<br />

YEW,DL708E MY<br />

Eight channels 10M/s sampling 10 bit 8M word of memory, 1.2Gb HDD<br />

(100k/s sampling continuously to disk). In-built printer, FDD, RS232, GpIb<br />

and VGA. Input ranges 5mV/div~200V/div . 800V isolated input capability<br />

(using x10 probes). Input filters, FFT, color display, measurement of 26<br />

waveform parameters. Simple and advanced trigger including a window<br />

trigger.<br />

DATA ACQUISITION & RECORDING<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 73

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!