electrical teSterS<br />

Hioki 3283 Clamp-on Leakage Current Tester<br />

HIO,3283-LEAKAGE-TES AU<br />

Analyser functions for filtering and output signals. Wide bandwidth<br />

5Hz~15kHz, high sensitivity with a full scale of 10mA, ranges 10mA, 100mA,<br />

1A, 10A & 200A primary. Resolution 10µA, high accuracy at ±1%,True rms<br />

measurement. Output monitor and record modes, ac/dc output 1~2V full<br />

scale. battery 9V approx 40h.<br />

current injectOrS<br />

SMC PET-100-C Secondary Current Test Set<br />

SMC,pTE-100-C AU/NZ<br />

AC current and voltage outputs in 4 ranges 200V/5A, 40V/25A, 20V/50A &<br />

10V/100A. Additional outputs ac voltage 0~220V at 1A (4A 1min), dc voltage<br />

0~350V at 0.7A (2.8A 1min), dc voltage 0~250V at 0.25A, fixed 110V ac at<br />

0.3A. Timer 1ms~99,999s. Additional functions include measurement of<br />

the phase angle between the voltage and the current output tap selected,<br />

and the measurement of the impedance of the load connected in the current<br />

output taps.<br />

Multi-Amp MS-2 High Current Test Set<br />

MUL,MS-2 AU<br />

Designed to test overload relays, circuit breakers and earth fault trip devices.<br />

Input 240V 50/60Hz. Output continuously adjustable in 4 ranges 120V/5A,<br />

24V/25A, 6V/120A & 3V/240A. Short term over current of several times the<br />

rated current ranges is possible. Digital current meter has read and hold<br />

facilities for short duration currents. Digital timer measures elapsed time<br />

between energisation and the test device operating.<br />

> NEW T&R PCU1-SP with CT Ratio/Polarity and NLU5000A<br />

Loading Unit<br />

T&R,pCU1-Sp NLU5000A AU<br />

Medium powered primary current injection system. Features 5kA maximum<br />

output current (higher overload current for 2s). Multi-function digital timing<br />

system. Digital true RMS memory ammeter. Solid state switching. 2000A<br />

and 5000A load units. Three range outputs on loading units. Rugged,<br />

compact design. Optional trolley mounting of system. Secondary injection<br />

up to 100A. Direct reading CT ratio and polarity. May be configured to either<br />

give a maximum current of 5000A on the 2.3V range, 2500A on the 4.6V<br />

range or 1250A on the 9.2V range.<br />

T&R PCU1/E 2000 A Primary Current Test Set<br />

T&R,pCU1/E AU<br />

Comprises control unit and 2kA loading unit. Control unit includes timer,<br />

current and voltage meters, and variable output transformer. Current output<br />

to 100A at 5V ac, 50A at 10V ac. Voltage output to 25A at 240V ac. External<br />

loading unit output to 30A at 240V ac. Outputs 2kA at 0~3V, 1kA at 0~6V.<br />

Two units: weigh 35 & 45kg plus cables.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

Equimp HT2035 Electrical Tester<br />

EQU,HT2035 NZ<br />

Complies with CEI 64-8 & CEI 64-4. Eight instruments in the one case which<br />

includes printer & RS-232C interface.<br />

Tests are:- 1. Low Ω range 0~20Ω, resolution 0.01. 2. 2 & 3 wire earth<br />

resistance measurement, range 0~1,999Ω. 3. Insulation resistance<br />

0~199.9MΩ, 250, 500 & 1,000V. 4. RMS ac 0~500V, resolution 1. 5. Short<br />

circuit loop impedance 0~1,999Ω, resolution 0.01. 6. Fault loop impedance<br />

measurement 0~1,999Ω. 7. Fault loop resistance 0~1,999Ω. 8. RCD<br />

tester.<br />

T&R 200 ADM Current Injection System<br />

T&R,200ADM AU<br />

Single phase portable current injection system with main and auxiliary ac,<br />

dc current and voltage outputs. Output ranges main voltage, 10, 35, 100<br />

& 240Vac & 240Vdc. Main current continuous, 1~25A, intermittent up to<br />

200A. Auxiliaries stabilised dc isolated and protected 1.04A @ 24V~0.11A<br />

@ 220V. Variable 300mA @ 0~130Vac. Resolution 100mV, 1mA, phase<br />

0.10. Timing range 0~999.999 with resolution 1ms. Metering LCD backlit<br />

true rms with a memory ammeter. Interface RS232. Protection main output<br />

duty cycle and auxiliaries, electronic thermal and fuse. Supply requirements<br />

1ph 115~230Vac 50/60Hz 2.3kVA max.<br />

T&R CIT/LU2000 Primary Current Injection Test Set<br />

T&R,CIT AU<br />

Comprises control unit and 2kA loading unit (LU). Control unit includes<br />

timer, current and voltage meters, and variable output transformer. External<br />

loading unit output 0~2kA, duty 5min on 15min off at 6V ac, continuous<br />

0~1kA at 3V ac. Two units weight 35 & 45kg plus 2 quad 70mm2 cable sets<br />

each 3m long. Control unit connects to LU with supplied interface cable.<br />

T&R 200A-3PH/ED 3 Phase Current Injection Tester<br />

T&R,200A3pHEDIT AU<br />

0~200A/phase output capacity. power supply 4 wire 5A/phase 3ph 240/415V.<br />

Typically 10A 5 pin 3 phase socket outlet HpM.<br />

ELEC<strong>TR</strong>ICAL POWER<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 65