RENTAL SOLUTIONS GUIDE 2007 - TR Corporation
RENTAL SOLUTIONS GUIDE 2007 - TR Corporation
RENTAL SOLUTIONS GUIDE 2007 - TR Corporation
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
electrical teSterS<br />
Hioki 3283 Clamp-on Leakage Current Tester<br />
HIO,3283-LEAKAGE-TES AU<br />
Analyser functions for filtering and output signals. Wide bandwidth<br />
5Hz~15kHz, high sensitivity with a full scale of 10mA, ranges 10mA, 100mA,<br />
1A, 10A & 200A primary. Resolution 10µA, high accuracy at ±1%,True rms<br />
measurement. Output monitor and record modes, ac/dc output 1~2V full<br />
scale. battery 9V approx 40h.<br />
current injectOrS<br />
SMC PET-100-C Secondary Current Test Set<br />
SMC,pTE-100-C AU/NZ<br />
AC current and voltage outputs in 4 ranges 200V/5A, 40V/25A, 20V/50A &<br />
10V/100A. Additional outputs ac voltage 0~220V at 1A (4A 1min), dc voltage<br />
0~350V at 0.7A (2.8A 1min), dc voltage 0~250V at 0.25A, fixed 110V ac at<br />
0.3A. Timer 1ms~99,999s. Additional functions include measurement of<br />
the phase angle between the voltage and the current output tap selected,<br />
and the measurement of the impedance of the load connected in the current<br />
output taps.<br />
Multi-Amp MS-2 High Current Test Set<br />
MUL,MS-2 AU<br />
Designed to test overload relays, circuit breakers and earth fault trip devices.<br />
Input 240V 50/60Hz. Output continuously adjustable in 4 ranges 120V/5A,<br />
24V/25A, 6V/120A & 3V/240A. Short term over current of several times the<br />
rated current ranges is possible. Digital current meter has read and hold<br />
facilities for short duration currents. Digital timer measures elapsed time<br />
between energisation and the test device operating.<br />
> NEW T&R PCU1-SP with CT Ratio/Polarity and NLU5000A<br />
Loading Unit<br />
T&R,pCU1-Sp NLU5000A AU<br />
Medium powered primary current injection system. Features 5kA maximum<br />
output current (higher overload current for 2s). Multi-function digital timing<br />
system. Digital true RMS memory ammeter. Solid state switching. 2000A<br />
and 5000A load units. Three range outputs on loading units. Rugged,<br />
compact design. Optional trolley mounting of system. Secondary injection<br />
up to 100A. Direct reading CT ratio and polarity. May be configured to either<br />
give a maximum current of 5000A on the 2.3V range, 2500A on the 4.6V<br />
range or 1250A on the 9.2V range.<br />
T&R PCU1/E 2000 A Primary Current Test Set<br />
T&R,pCU1/E AU<br />
Comprises control unit and 2kA loading unit. Control unit includes timer,<br />
current and voltage meters, and variable output transformer. Current output<br />
to 100A at 5V ac, 50A at 10V ac. Voltage output to 25A at 240V ac. External<br />
loading unit output to 30A at 240V ac. Outputs 2kA at 0~3V, 1kA at 0~6V.<br />
Two units: weigh 35 & 45kg plus cables.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
Equimp HT2035 Electrical Tester<br />
EQU,HT2035 NZ<br />
Complies with CEI 64-8 & CEI 64-4. Eight instruments in the one case which<br />
includes printer & RS-232C interface.<br />
Tests are:- 1. Low Ω range 0~20Ω, resolution 0.01. 2. 2 & 3 wire earth<br />
resistance measurement, range 0~1,999Ω. 3. Insulation resistance<br />
0~199.9MΩ, 250, 500 & 1,000V. 4. RMS ac 0~500V, resolution 1. 5. Short<br />
circuit loop impedance 0~1,999Ω, resolution 0.01. 6. Fault loop impedance<br />
measurement 0~1,999Ω. 7. Fault loop resistance 0~1,999Ω. 8. RCD<br />
tester.<br />
T&R 200 ADM Current Injection System<br />
T&R,200ADM AU<br />
Single phase portable current injection system with main and auxiliary ac,<br />
dc current and voltage outputs. Output ranges main voltage, 10, 35, 100<br />
& 240Vac & 240Vdc. Main current continuous, 1~25A, intermittent up to<br />
200A. Auxiliaries stabilised dc isolated and protected 1.04A @ 24V~0.11A<br />
@ 220V. Variable 300mA @ 0~130Vac. Resolution 100mV, 1mA, phase<br />
0.10. Timing range 0~999.999 with resolution 1ms. Metering LCD backlit<br />
true rms with a memory ammeter. Interface RS232. Protection main output<br />
duty cycle and auxiliaries, electronic thermal and fuse. Supply requirements<br />
1ph 115~230Vac 50/60Hz 2.3kVA max.<br />
T&R CIT/LU2000 Primary Current Injection Test Set<br />
T&R,CIT AU<br />
Comprises control unit and 2kA loading unit (LU). Control unit includes<br />
timer, current and voltage meters, and variable output transformer. External<br />
loading unit output 0~2kA, duty 5min on 15min off at 6V ac, continuous<br />
0~1kA at 3V ac. Two units weight 35 & 45kg plus 2 quad 70mm2 cable sets<br />
each 3m long. Control unit connects to LU with supplied interface cable.<br />
T&R 200A-3PH/ED 3 Phase Current Injection Tester<br />
T&R,200A3pHEDIT AU<br />
0~200A/phase output capacity. power supply 4 wire 5A/phase 3ph 240/415V.<br />
Typically 10A 5 pin 3 phase socket outlet HpM.<br />
ELEC<strong>TR</strong>ICAL POWER<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 65