Hioki 3128 Clamp-on Current Transducer<br />
HIO,3128 AU<br />
Clamp-on current meter with recorder output. Ranges full scale 15A~1.5kA.<br />
Output 200mV dc full scale. Batteries not required. Output is intended only<br />
for low speed recorders.<br />
Yokogawa 2255-01 10A ~ 5A Current Transformer<br />
YEW,2255-01 AU<br />
Input 10Aac, output 5Aac, max circuit voltage 3.45kV, burden 15VA, accuracy<br />
1% of rated value, bus bar connectors.<br />
Yokogawa 2215 Current Shunt<br />
YEW,2215 AU/MY<br />
50mV output, available in range of 1A~1kA.<br />
Crompton 235/50 Frequency Transducer<br />
CI,253/50 AU<br />
Input 240V ac, 45~55Hz, output 0 ~1mA.<br />
Moore FDT Frequency to Volts Transducer<br />
MOR,FDT AU<br />
Input range 6.5~12.5kHz at up to 20V peak to peak. Output 5Vdc at<br />
12kHz.<br />
Yokogawa 2261-01 2.2kV Potential Transformer<br />
YEW,2261-01 AU<br />
3.3, 2.2kV, 440 & 220V primary to 110V secondary.<br />
Jacobs Radio CT-005 Current Transducer<br />
JR,CT-005 AU<br />
Range 5kA, 2kA & 1kA. 1V dc output. Transformer can be split in two to<br />
accommodate cable or bus 22 x 55mm.<br />
Phase Sequence Meter 110 - 600 volts 50 / 60 Hz<br />
KYO,pSM8031 AU<br />
KYO,8031 MY<br />
phase indicator with open phase checker and phase indicator designed to<br />
check the presence of open phase and also the phase sequence by rotating<br />
disk and lamps. Check a wide range of 3ph power source from 110~600V.<br />
Operational voltage 110~600Vac, time limit for continuous >500V within 5min.<br />
Frequency response 40~200Hz(ac 110~200V), 40~400Hz(ac 200~600V)<br />
safety standard IEC61010-1 CAT.III 600V pollution degree 2 withstand<br />
voltage 2.2kVac for 5s. Dimensions 106L × 75W × 40Dmm, weight 350g<br />
approx. Cord 1.5m(R: red S: white T: blue)<br />
Beha 5774E 3 Phase Sequence/Rotation Indicator<br />
bEH,5774E AU<br />
For determing the rotational direction and sequence of a 3ph supply.<br />
Necessary to pre-determine the correct rotational direction of 3ph motors.<br />
Kikisui PLZ1002W Electronic Load<br />
KIK,pLZ1002W AU/MY<br />
Voltage range 3~110V. Current range 0~200A. In-built oscillator provides<br />
for dynamic load testing by switching between two different load levels.<br />
Load current may be remotely controlled by voltage or resistance signals.<br />
Multiple units may be operated in parallel. In-built digital volt/current meter.<br />
For dc inputs only.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
electrical tranSducerS<br />
Universal Technic P75.3C dc/ac Amp Clamp<br />
UNI,p75-3C AU<br />
Max current 7,500A dc & ac peak. bandwidth 1KHz. Min range 1kA.<br />
Accuracy at 75A 10% of reading. FS accuracy 2% of reading. Max bus size<br />
122 x 54mm or 100 x 64mm. Max cable size 83mm. battery 9V - life 100h.<br />
Output sockets 4mm. DC current gives dc output, ac current gives ac output,<br />
4kA range 0.5mV per amp, 7.5kA range 0.2mV per A.<br />
Robinson 543 Linear ac Current Transducers<br />
ROb,543 AU<br />
Wide bandwidth and very wide dynamic range. Supplied with an open<br />
ended flexible coil of 3m length which may be wrapped around a very large<br />
conductor or power pole, etc. Frequency range 10Hz~10kHz with 1%<br />
accuracy. Current range for 1 wrap of coil 1A~2MA at 50Hz. phase error<br />
< 0.04deg. Min bending radius 60mm. External insulation is required for<br />
metallic conductor. Output voltage 2V rms ac waveform. Also dc rectified<br />
output. In-built digital display.<br />
LEM FLEXII 30, 300 & 3,000A Transducer<br />
LEM,LEM-FLExII AU<br />
Flexible wrap-around ac current transducer. Length 600mm. Ranges 30,<br />
300A & 3kA. Frequency response 1~20kHz. Accuracy 1%. phase error<br />
0.5O. Output 3Vrms @ full scale. Requires 3 units for 3ph. Designed for<br />
multimeters and oscilloscopes (4mm banana plug or bNC connectors) but can<br />
also be used with the DRA,808 (requires adaptor lead), or VOL,pM3000A.<br />
Other instruments may be attached providing the correct adaptor/transducer<br />
and connection is available. Operates for 100h from 2 x 9V batteries.<br />
electrical teSterS<br />
Biddle 550005 Turns Ratio Test Set<br />
bID,550005 AU<br />
Single phase (can be used on 3ph individual phase windings). Turns ratio<br />
0.001~129.999. Exciting current 0~1A. Accuracy 0.1%. Hand cranked<br />
operation.<br />
AVO Penta-Plus DMM Analyser<br />
AVO,pENTA-pLUS-DMM AU<br />
Multifunction meter for measuring 1 & 3ph volts ac, primary and secondary<br />
current, true and reactive power, amplitude and phase angle, and also<br />
frequency. Easily configured to measure the amplitude and phase angle<br />
between any 2 current or voltage inputs. Displayed simultaneously on a<br />
backlight graphic LCD screen. Internal memory records up to 60 test results.<br />
Logging via RS232C port. parallel printer port. Voltage 0~650Vac, 9 ranges<br />
with 0.1% resolution. Max 1kV. Current 0~100A ac in 11 ranges, with 0.1%<br />
resolution. phase angle 0~360O with 0.1O resolution. power true and<br />
reactive ±0-100kW & ±0~100kVAr. Frequency 45~65Hz. Timer 0~999.999.<br />
Line or battery operated, 3h continuous on full charge.<br />
Metrix MX120 Multicore Clamp-on Meter<br />
MET,Mx120 AU<br />
Measures current in 1, 2, or 3 wire cables. No need to split cables or remove<br />
covers. Ranges 2 or 3 wire 0~40A, 1 wire 0~199.9A resolution 0.1A.<br />
Accuracy 5% with 2 or 3 wire oval or flat cable, 12% with round cable, 1.5%<br />
with single wire. battery operated. Display 3½ digit.<br />
Hioki 3282 Clamp-on Hi Tester (V, I, Hz & T)<br />
HIO,3282 AU<br />
Measures True rms, peak, min/max & hold. Ranges auto/manual, current<br />
30A, 300A & 1kA rms. Voltage 300/600V (1kVmax). Resistance 1/10kΩ.<br />
Frequency 40~100Hz & 66Hz~1kHz. Jaw capacity 46mmØ (50mm opening).<br />
Battery life approx 1.5h continuous.<br />
ELEC<strong>TR</strong>ICAL POWER<br />
MALAYSIA<br />
603 5632 1135<br />
www.techrentals.com.my 63