Voltech PM3000A 3 Phase Power Analyser<br />

VOL,pM3000A AU<br />

Capable of making measurements of all standard electrical characteristics<br />

of 1 & 3 phase supplies. Measures inrush current and crest factor, load<br />

impedance and harmonic analysis, energy and max demand, extendable<br />

using current and potential transformers. Frequency range dc~500kHz.<br />

parameters W, VA, Var, V, A, pF, peak voltage and current, crest factor,<br />

impedance, peak inrush current, voltage and current harmonics, 99th order,<br />

THD, Hz, Wh, VAh, Varh, Amph, average pf. Input coupling may be ac or ac<br />

+ dc. Outputs printer, recorders (8), and oscilloscopes. IEEE, RS232C, and<br />

centronics interfaces and waveform output derived from current and voltage<br />

inputs are included. Accuracy V & A 0.05%, power 0.1%. Input ranges<br />

voltage 0.5V~1kV rms, current 0.05~30A rms (200A peak). Accessories<br />

3 x 1kA clamp-on CTs, and 3 x precision 100A/1kA dual range current<br />

transformers 0.2% (not clamp on).<br />

Voltech PM3000A with NATA Calibration<br />

VOL,pM3000A-NATA AU<br />

Specifications as above but with NATA calibration.<br />

LEM Analyst 2060 Hand-held 1 Phase Clamp-on Power Meter<br />

Analyser<br />

LEM,ANALYST-2060 AU<br />

Measure, record and log W, VA, VAR, kWh, and power factor. Current to<br />

2kA auto-ranging ac or dc. peak, Crest Factor, THD, DF and frequency for<br />

voltage (4~750V) and current. Harmonics to the 25th order. Time base is<br />

selectable from 2ms/div~50ms/div. Large backlit multi parameter display,<br />

with oscilloscope and chart modes. Memory size: 8 screens smart save and<br />

up to 10,000 readings. Jaw opening capacity 60mmØ. Typical battery (6 x<br />

AA alkaline) life 24h without backlight.<br />

LEM Topas 1000 Power Network Analyser<br />

LEM,TOpAS1000 AU<br />

Measures all relevant parameters in one measurement system. Inputs<br />

(isolated) voltage 4 channels, 200mV~1kV, current 4 channels, supplied<br />

with 4 x 0~10A, 10~100A ac clamp-on CTs and 4 x (unit powered) 0~3kA<br />

LEM-Flex current sensors. Can be configured for 8 voltage channels.<br />

Measuring functions rms, V(U) voltage imbalance, positive, negative & zero<br />

phase sequence, phasor (vector) diagrams, amps (I)a, pf, kVA, kVAr, f(Hz),<br />

energy, on-line oscilloscope, power and multimeter, harmonics (by power/<br />

direction, magnitude & phase), inter-harmonics, THD, flicker, transients<br />

(100kHz~10MHz), will capture events from 0.1µs in duration. Software<br />

configured manual or auto trigger levels, ethernet or serial interface, memory<br />

>540Mb/HDD.<br />

LEM Memobox 300 Network Performance Analyser<br />

LEM,MEMObOx300 AU<br />

Weatherproof (Ip65)3ph power analyzer. High accuracy to Class A IEC<br />

61000-4-30. Suitable for 50Hz or 60Hz systems. LEMflex flexible current<br />

probes with ranges 15, 150, 1,500 & 3,000A suitable for conductors up<br />

to 178mmØ. Voltage ranges from 115~830V on 3 or 4-wire systems.<br />

Measures V, A, kW, kVA, kVAR, kWHr, pF, Hz, crest factor, distortion power,<br />

THD, individual harmonics of volts & current up to 50th harmonic, flicker and<br />

ripple control signal levels. Power measurements by either 2 or 3 wattmeter<br />

method. power supply 88~415V either from measurement leads or separate<br />

supply. Memory size 4Mb with 5,700 sampling intervals. Sampling intervals<br />

selectable from 1s~60min. Sample interval of 5min records for >19Days.<br />

Linear or circular (overwrites earliest data once full) memory. Records<br />

average, 10ms min & 10ms max in each interval. Captures motor start<br />

current spikes with corresponding voltage-dips. Captures up to 13,000<br />

voltage sag/surge events 10ms or longer. Weight 1.1kg.<br />

AUS<strong>TR</strong>ALIA<br />

1800 632 652<br />

www.techrentals.com.au<br />

NEW ZEALAND<br />

0800 832 473<br />

www.techrentals.co.nz<br />

pOWer analySerS & recOrderS<br />

LEM Elmes 693 3Ph Power Logger<br />

LEM,603 NZ<br />

Logs, voltage, current & pF. True RMS: VA, VAr, pF, Volts, A & frequency.<br />

Sampling rate is 1s. Statistical measurement interval can be set from<br />

1~60min. Supplied with flexible 1kA Rodowski CTs, 5A clip-on CTs and<br />

software for programming and uploading results. Accuracy, active power<br />

±2%, reactive power ±3%, phase angle ±3%, voltage ±1.5%.<br />

Reliable Power Systems 1600 Analyser<br />

REL,1600 AU<br />

Power analyser for parameter, demand, and disturbance measurement<br />

and long term monitoring. pC required for download - no onboard display.<br />

Complete with 1kA CT’s & 5A CT’s. V & I sampled at 8kHz, min/max values<br />

have 1 cycle response. Impulses sampled at 2 & 4MHz software selectable.<br />

Max input voltage 700V rms. Notebook pC with Win 95 and Office 97<br />

included.<br />

Algodue UPM6001 Power/Demand Analyser<br />

ALG,UpM6001 AU<br />

Includes 3 x 1kA clip-on current transformers. Integral digital display and<br />

printer. Memory 512kb plus RS232 interface for data transfer. Measures<br />

each phase & total V, A, power, pF, VA, VAR. Measures demand over a<br />

defined interval, harmonic distortion, and provides FFT analysis. Records<br />

maxima and minima. Current inputs are at 1V or 5A for external CT’s.<br />

Voltage drop detection for durations exceeding 150ms. Software provides<br />

time plots and remote display of measurement parameters. Higher speed<br />

FFT harmonic plot possible up to 25th harmonic.<br />

Algodue UPM6100 Uni Power Meter 500Hz & Rogowsky 3kA<br />

Options<br />

ALG,UpM6100 AU<br />

power meter 3kA Rogowski current transducer (flexible CTs), 14~500Hz,<br />

harmonic distortion current and voltage 50th order. Large 4Mb memory.<br />

Algodue Ret Set of 3 Rogowski Transducer<br />

ALG,RET<br />

Use with the ALG,UpM6001. Ranges 300A/3kA. powered from analyser.<br />

> NEW Hioki 3197 Power Quality Analyser with 3x1000A<br />

Clamp-on CTs<br />

HIO,3197pQA AU<br />

Monitors inrush current, voltage swell, voltage dips, transient over-voltage<br />

and interruptions. Measure and records power and power factor, active/<br />

reactive energy, demand, load changes (with graph display), voltage and<br />

current. Measures impulsive voltage quality. RMS voltage quality, voltage<br />

swell, voltage dips & voltage interruption. Power quality, frequency, voltage,<br />

current, current peak, active/reactive/apparent power & power factor<br />

(displaced power factor). Three phase quality, voltage unbalance ratio,<br />

current unbalance ratio, harmonic quality (up to 50th order). Harmonic,<br />

voltage, current, ower, voltage/current phase angle. Total harmonic, voltage<br />

distortion, current distortion (THD-F, THD-R).<br />

ELEC<strong>TR</strong>ICAL POWER<br />

MALAYSIA<br />

603 5632 1135<br />

www.techrentals.com.my 53