DATA ACQUISITION & RECORDING<br />
76<br />
Strip chart recOrderS<br />
Yokogawa 3057-22 2 Pen Portable Recorder<br />
YEW,3057-22 AU/NZ<br />
Twelve input ranges 10mV~50V fs, 150mm x 15m Z fold or roll chart, speeds<br />
20mm/h~600mm/min. Accuracy 0.5%. power 240/50Hz, rechargeable<br />
NiCad battery or 12Vdc external.<br />
Yokogawa 3712-31 3 Pen Vertical Chart Recorder<br />
YEW,3712-31 AU<br />
Input ranges dc voltage 10mV~200V fs. Thermocouples including type T<br />
& K. Chart speed 10mm/h~20mm/s. pen offset compensation. Memory<br />
card optional.<br />
Yokogawa 3712-41 4 Pen Vertical Chart Recorder<br />
YEW,3712-41 AU<br />
Input ranges: dc voltage 10mV~200V fs. Thermocouples including type T<br />
& K. Chart speed 10mm/h~20mm/s. pen offset compensation. Memory<br />
card optional.<br />
Yokogawa 3750 10 Channel Multipoint Recorder<br />
YEW,3750 AU<br />
Ten channel hybrid recorder. Input ranges dc 20mV~20V, thermocouple,<br />
RTD. Scans 10 channels in 2s. AC mains operation.<br />
vOltage current recOrderS<br />
Tech-Rentals CT Terminations for Hioki 8710, etc<br />
<strong>TR</strong>,CT-5 AU<br />
Termination box for 5A output current transformers. For use mainly with<br />
HIO,8710. Comprises quantity 3 shunts 0.04Ω. Output 0.2V @ 5A. Use<br />
with DRA,<strong>TR</strong>2015’s.<br />
Hioki 8206 2 Channel Voltage & Current ac Chart Recorder<br />
HIO,8206 AU<br />
The chart records a true rms. Equivalent reading. AC voltage channel, 3<br />
ranges 50~140V, 100~280V & 250~600V. AC current channel, 0~10, 0~20,<br />
0~50, 0~100, 0~200 & 0~500. Chart speeds 600mm/h~20mm/h. Note the<br />
supplied 9651 clamp-on current probe will measure max 46mmØ conductor.<br />
Frequency range of the clamp 40Hz~1kHz.<br />
tape recOrderS<br />
Teac 16 Channel DAT Instrumentation Recorder<br />
TEA,RD145T AU<br />
Sixteen channel DAT instrumentation/data tape recorder. 4ch~20kHz, 8ch-10kHz, 16ch~5kHz, ac/dc operation. Ch 1 can be selected for analogue or 14-bit<br />
digital. Data recorded at slow speeds can be played back at double speed. Input ranges 0.5, 2, 5 & 20Vp impedance 100kΩ unbalanced output ranges 2~5Vp<br />
variable impedance 75Ω unbalanced. AC or 11~30V dc operation.<br />
plOtter printer<br />
Yokogawa 3750-DC 20 Channel Hybrid Recorder<br />
YEW,3750-DC AU<br />
Input ranges dc 20mV~50V, thermocouple & RTD. Scans 20 channels in 2s.<br />
Operates from 10~32V external dc. RS232C interface option fitted.<br />
Yokogawa 3760 30 Channel Recorder<br />
YEW,3760 AU<br />
Analogue and digital printout. Ten colour with channel identification number.<br />
Scans in 2s. Chart speeds 1~1500mm/h. Inputs dc (20mV~50V range),<br />
thermocouple (R, S, b, K, E, J, T, L, U, N, W, Kp) & RTD. Memory card<br />
reader. Memory card included with several typical set-ups.<br />
Yokogawa DR130 Hybrid 20 Channel Recorder FDD<br />
YEW,DR130 AU<br />
Includes 3.5” FDD. Input unbalanced floating 20mV~50Vdc, TC, RTD and<br />
contact. Accuracy 0.05%. Reads 20 channels in 2s. Recording width<br />
150mm. Data can be saved to 500k of internal RAM either directly or due to<br />
alarm conditions. The saved data can be copied to a 3.5” FDD file suitable<br />
for inclusion in standard spreadsheet programmes.<br />
Yokogawa 512K Memory Card for Yokogawa Recorders<br />
YEW,MEM512 AU<br />
Memory card 512k. For YEW,3750, YEW,3760, YEW,3712-31 YEW,3712-<br />
41 and YEW,3701-85 recorders.<br />
Hioki 8710 3 Channel ac/dc Recorder<br />
HIO,8710 AU/NZ<br />
Intended mainly for recording ac line voltage and current. Data is recorded<br />
graphically and printed. Input voltage ranges 70~750V rms ac in 4 ranges<br />
with optimised scale, 0.05~7.5V dc in 5 ranges. AC current ranges using<br />
9008 and 9132 clamp-on probes 10~1000A. Uses type 9221 thermal paper<br />
110mm x 30m. The recorder is suitable for voltage measurements from pAM<br />
thyristor inverters but not all voltage levels with PWM inverters. Chart speed<br />
up to 30 div/min (1div is 9mm). Response time 0.6s.<br />
HP 7440A 8 Pen Plotter<br />
Hp,7440A MY<br />
Media sizes. 210 x 297mm (ISO A4) 8.5 x 11in (ANSI A). Regular plotter paper,glossy presentation paper, fast-dry overhead transparency film. 8 fiber-tip pens,<br />
automatic pen changing & capping. Max plotting area: Y-axis 191mm (7.5in) for A & A4 size paper, x-axis 257mm (10.1in) for A size paper. Resolution:<br />
addressable step size: 0.025mm (0.001 in). pen Velocity: pen up 52 cm/s (20 in/s). pen down max 40 cm/s (16 in/s), programmable 1 to 40 cm/s in 1 cm/s<br />
increments. Acceleration: approx 1.2 g’s. Interface Options: RS-232-C/CCITT V.24 Asynchronous serial, ASCII, 60-byte buffer size.Switch selectable baud<br />
rates: 75~9600. Switch selectable parity: odd, even, or off. HpIb: Switch selectable addresses: 0~31 (31 sets listen-only mode). Size: 308(d) x 460(w) x<br />
125(h)mm. Weight: plotter 4.1kg. power supply 1.4kg.