01.12.2012 Views

RENTAL SOLUTIONS GUIDE 2007 - TR Corporation

RENTAL SOLUTIONS GUIDE 2007 - TR Corporation

RENTAL SOLUTIONS GUIDE 2007 - TR Corporation

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ELEC<strong>TR</strong>ICAL POWER<br />

60<br />

electrical tranSducerS<br />

Model Type Input Type (V) Input Ranges Output (V)<br />

CAT,CL-8-36 pH STICK Indoor two-pole tester 2~36kV<br />

MEG,DH2-6M Duplex handspikes for 10AmΩ meter 30Vac/dc 20A max.<br />

HIO,9661-01<br />

500A<br />

Clamp-on sensor<br />

HIO,9669-CCT-1000A 1,000A<br />

HIO,9667-FCT-5000A Flexible clamp-on sensor 500A/5,000A<br />

UNI,p75-3C HYbRID-Dp<br />

2Vac/dc 7,5000A/1.5V<br />

500-mVac<br />

HIO,3290CLAMpONAC/DC Clamp-on<br />

dc to 15kHz 2840A peak 1mV/A<br />

CHK,CR100S 100A<br />

LEM,CURRENT pRObE10A<br />

YEW,3228-11 High sensitivity clamp-on ammeter ac/dc current 50mA, 20A ac/dc 0~100mV ac/dc<br />

ALG,C173<br />

High sensitivity clamp-on ammeter & earth<br />

leakage<br />

Algodue only 0.001 ~ 1,000A 1mV~1V/A<br />

HIO,3128 Clamp-on ammeter ac current 15A, 1.5kA 0~200mV dc<br />

HIO,3285<br />

200A, 2kA, 1kHz 0~1 ac/dc, 0~1 V<br />

bEL,CG-120A 50, 500A 0 ~ 0.5 ac/dc<br />

ac/dc current<br />

UNI,p75-3C Current clamp<br />

4, 7.5kA 0~2/ 0~1.5 ac/dc<br />

HIO,3109 100, 250, 500,1kA 0~1 dc<br />

CHA,D35N<br />

1, 2, 3kA 0~5A ac<br />

FLU,80I,100S 0~10, 0.5~100, 5~1000A 1mA/A<br />

YEW,2215 Current shunt<br />

ac current<br />

1A, 1kA 0~50mV ac<br />

JR,CT-005 ac current dc volts 1, 2, 5kA 0~1dc<br />

ROb,543<br />

Rogowski coil<br />

1A ~ 2MA 0~2 ac<br />

LEM,LEM-FLExII 30, 300, 3kA 0~3 ac<br />

LG,FIC-51E True RMS transducer<br />

500V 0~5 dc<br />

<strong>TR</strong>,M05 Instrument transformer ac voltage<br />

100V, 500V rms 0~5 ac rms<br />

YEW,2261-01 Med voltage transformer (3.3kV) 220, 440V,2.2, 3.3kV 0~110 ac<br />

MOR,FDT<br />

0~20ac 50~1.6kHz 1~5 dc<br />

CI,253/50<br />

0~1mA<br />

Frequency transducer<br />

240 ac 45~55 Hz<br />

CT,891040-240 0~10 V dc<br />

CT,891040-110 110 ac 55~65 Hz 0~10 V dc<br />

CWE,230V Transducer ac voltage 230V 1mV/1V<br />

CAR,3-<strong>TR</strong>ANS Converter ac current 5A 0~10V dc<br />

> NEW CATU C-8-36 Phasing Stick-Two pole Phase<br />

comparator for Indoor Use<br />

CAT,CL-8-36 pH STICK AU<br />

Detect differences in voltage between any 2 points of an installation indicated<br />

by LED’s. Enables assessment of the residual voltage induced by nearby<br />

live lines or circuits, and differentiates it from the one provided directly from a<br />

high voltage source. Features, range of voltages 2kV~36kV, high luminosity,<br />

compact 0.62m with probes dismounted, high dielectric quality insulating<br />

material, 2 x 1.25m elements with removable probes, connected via a highinsulation<br />

lead, max use distance 2.25m (with probe extenders), operation<br />

testing with a checking device.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!