01.12.2012 Views

RENTAL SOLUTIONS GUIDE 2007 - TR Corporation

RENTAL SOLUTIONS GUIDE 2007 - TR Corporation

RENTAL SOLUTIONS GUIDE 2007 - TR Corporation

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ELEC<strong>TR</strong>ICAL POWER<br />

56<br />

pOWer analySerS & recOrderS<br />

CHK PM30 3 Phase Powermonic Power Logger<br />

CHK,pM30 AU/NZ<br />

Weatherproof Ip65 field unit. Channels 3 voltage, 63~440V (isolated), 4<br />

current 0~3kA (3ph & neutral) rms. Supplied with 3 x 1kA clamp-on CTs<br />

(cable capacity 50mm). Clamp-on CTs of 3kA, 1kA for large conductors<br />

and 500A & 100A for neutral conductor current measurement are available.<br />

Memory 4Mb. In-built 2 line LCD display. Records V, A, pf, f(Hz), kVA,<br />

kVAr, kW, harmonics, (THD and individual to 48th ). Total energy, tariffs,<br />

max demands, transient and sub-cycle disturbances. Software provides<br />

graphs and summaries to PC. Download files while logging via RS232<br />

interface. pC using Win 95, 98, NT4, 2000, xp, O/S, is required with the<br />

CHK POWERview software to configure this unit before operating.<br />

CHK PM20 Power Quality Analyser/Logger<br />

CHK,pM20 AU<br />

Three phase, weatherproof Ip65 field unit. Three voltage channels 63~440V<br />

(isolated). Four current channels 0~3kA rms (3ph & neutral). Supplied with<br />

3 x 1kA clamp-on CTs (cable capacity 50mm), 3kA for large conductors and<br />

500A for neutrals clamp-on CTs are available. Memory 4Mb. In-built 2 line<br />

LCD display. Records V, A, pf, f(Hz), kW, kVA, kVAr, THD, total energy and<br />

tariffs, high speed rms waveform capture events outside preset limits (10ms<br />

intervals). Software provides graphs and summaries to PC. Download<br />

files while logging. RS232 interface. pC using Win 95, 98 or NT4 O/S, is<br />

required with the CHK POWERview software to configure this unit before<br />

operating.<br />

CHK 3 Phase Converter for CTs 1A Input to 200mA Output<br />

CHK,CK1 AU<br />

Adaptor for CTs with 1A secondary outputs, this unit suits CHK,pM30/20.<br />

External Modem 56k Remote Communication for CHK,PM30/<br />

PQA<br />

CHK,MODEM-56K AU<br />

External modem 56k for CHK pM20, CHK pM30, CHK pM30pLUS or any<br />

other power quality analyzer. Modem gives remote access control to setup/download<br />

any connected Instrument.<br />

CHK 3 Phase Converter for CTs 5A Input to 200mA Output<br />

CHK,CK5 AU<br />

Adaptor for CTs with 5A secondary outputs, unit suits CHK,pM30/20.<br />

CHK CR100 Clamp-on CT<br />

CHK,CR100 AU<br />

Jaws 43mmØ inside. Use with CHK,pM20 or pM30 for use as fourth CT to<br />

measure neutral current. Accuracy Class 1.<br />

CHK CR500 Clamp-on 500 CT<br />

CHK,CR500 AU<br />

Jaws 43mmØ inside. Use with CHK,pM20 or pM30 for use as fourth CT to<br />

measure neutral current. Accuracy Class 1.<br />

CHK CT1000L Large 1kA Primary Clamp-on CT<br />

CHK,CT1000L AU<br />

Large 123 x 35mm 1kA primary clamp-on CT for CHK,pM20/30.<br />

Gridsense 3000 Amps Flex CT 600 mm<br />

CHK,CT3000 pLUS AU<br />

CHK CT3000L Large 3kA Primary Clamp-on CT<br />

CHK,CT3000L AU<br />

Large 123 x 35mm 3kA primary clamp-on CT for CHK,pM20/30.<br />

Metrix MX200 ac/dc Clip-on Power Meter<br />

MET,Mx200 AU/MY<br />

Ranges 19.99 & 199.9A. Measures voltage to 750V, frequency to 999Hz,<br />

power 1.99 & 19.99kW, apparent power 1.99 & 19.99kVA, & pf. Recorder<br />

output via special leads (supplied) for current range only, 5mV/A on 199.9A<br />

range. Switch in battery compartment gives ac as well as dc output. Internal<br />

battery for 70h operation. Clamp capacity 23mmØ or 20 x 10mm bars.<br />

Metrix MX2040 ac/dc Clamp-on Meter<br />

MET,Mx2040 AU/NZ<br />

Measures A, V, Hz, kW, kVA, kVAR, kWH, pF and resistance. Ranges 200A<br />

& 2kA, 600V & 1kV, 20, 200kW & 2MW & kWH. Scale length 3,000. 1 &<br />

3ph operation. Motor rotation indication. peak, min, max, average, rms, and<br />

crest factor indication. peak response time 1µs. Analogue output option<br />

fitted giving dynamic signals and calculated parameters (energy, etc).<br />

Martindale Phase Sequence & Continuity Indicator 100~600V,<br />

50/60Hz<br />

MAR,pSCI424-585 AU<br />

Tester may be used, on 3ph circuits, to check the presence & sequence<br />

of the phases. Important on motor circuits as a phase reversal will cause<br />

a motors direction to reverse. Tester will give visual indication of loss of<br />

phase or an incorrect sequence. Tester is supplied in 2 forms - probe style,<br />

the connection to the tester is via 3 insulated cables to 3 fused test probes,<br />

1 with an insulated crocodile clip. plug style, a 16A, 4 pin, 3ph & earth,<br />

bS4343 plug is fitted to the tester. Use as a socket tester prior to plugging<br />

in 3ph equipment. Testers supplied in a plastic wallet, with full instructions.<br />

Caution, the unit should be checked for correct operation using a known<br />

voltage before use.<br />

Yokogawa CW140 Demand/Harmonics Analyser<br />

YEW,CW140 AU/NZ<br />

Includes 4 x 500A clip on current transformers, jaws 30mmØ inside. Current<br />

transformers are accurate at currents of

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!