ELEC<strong>TR</strong>ICAL POWER<br />

58<br />

prOtectiOn relay teSting SyStemS<br />

T&R DVS3-HP Static Relay Test System<br />

T&R,DVS3-Hp AU<br />

Test system for testing voltage and frequency protection relays and<br />

transducers. Tests Automatic Voltage Regulating (AVR) relays with line drop<br />

compensation, under and over voltage relays, directional over~current relays,<br />

df/dt (ROCOF) relays, vector surge (step change of phase) relays and check<br />

synchronising relay. Generates a 3ph voltage output from a 1ph supply,<br />

and may be used in conjunction with a current source to test directional<br />

protection. Requires 1ph 50/60Hz supply of 115V or 230V (±15%). Unit<br />

automatically selects the correct range. Max power requirement of the unit<br />

is 0.5kVA. DVS3-Hp has 3ph star connected output and the rating of each<br />

phase is:- voltage 0~133V phase to neutral, current 5min on/15min off 330mA<br />

@ 133V, or 200mA continuous, phase lock 45Hz~65Hz., variable frequency<br />

40~999.9Hz., variable phase angle ±180 O . Delta loads may be connected<br />

directly to the output or through the DVS-T VT box. Max voltage obtainable<br />

is 133V between any phase & neutral and 266V between 2 phases (if the<br />

phase angles of the 2 phases are set to 180 O apart). DVS-T VT box may be<br />

used to double these output voltage (Ratio 1:2).<br />

Get more done.<br />

> NEW<br />

Programma EGIL Circuit Breaker Analyser<br />

pRO,EGIL-Cb ANALYZER AU<br />

One main contact per phase. Three time channels are connected together<br />

on one side. Events at parallel contacts equipped with pre-insertion resistors<br />

are recorded and displayed simultaneously. Two separate time channels<br />

for measurement of auxiliary contacts. On-site hookup comes with readymade<br />

multi-cable sets for both main and auxiliary contacts. Coil currents<br />

are measured automatically, presented together with other readings<br />

immediately after testing on the display window or via the built-in printer. A<br />

built-in sequencer (program unit) sets the instrument automatically for the<br />

next sequential breaker operation. Intended primarily for measuring travel<br />

(motion). Can be equipped with an optional serial interface (RS232C) for<br />

communication with a pC and the CAbA Win breaker Analysis Software.<br />

More tools for commercial and plant technicians.<br />

Get the job done faster and more accurately with Fluke’s innovative set of tools for electrical<br />

test. From IR thermometers to clamp meters, every rugged tool delivers the reliabilty, accuracy<br />

and safety you expect from Fluke.<br />

Power Quality compliant load studies, energy consumption<br />

testing and general power quality logging.<br />

Verify your power. The Fluke 1735 Power Logger is the ideal technician’s tool for conducting<br />

30-day load studies.<br />

• Set up in seconds<br />

• Measure all 3 phases and neutral<br />

• Log most electrical parameters, plus harmonics and voltage events<br />

More information and resources.<br />

You can always count on Fluke for the troubleshooting techniques, application information, and<br />

training to keep your electrical systems up and running.<br />

Fluke. Keeping your world<br />

up and running.<br />

Power Quality<br />

Analysers<br />

Earth Ground<br />

Testers<br />

Fluke Australia Pty Ltd.<br />

Phone: (02) 8850 3333<br />

Fax: (02) 8850 3300<br />

Email: sales@fluke.com.au<br />

©2006 Fluke <strong>Corporation</strong>. All rights reserved. Ad 01981<br />