ELEC<strong>TR</strong>ICAL POWER<br />
40<br />
magnetic field meterS - gauSS teSla<br />
Model Type Frequency (Hz) Range (G) Electric Field Output<br />
ARL,GM AC magnetic field meter 12~1,300 9.9 ~ 99mG CRO<br />
HOL,HI-3627 Vector AC magnetic field meter 5~2,000 0.2 ~ 20<br />
HOL, HI-3604 AC field strength meter 50~100 0.1 ~ 20,000mG 1~200,000V/meter<br />
TES,70 AC magnetic field meter 30~600 0.1 ~ 1,999mG<br />
HMI,GM04<br />
bEL,4080 Digital gauss meter<br />
40~600 0.1mG ~ 511mG<br />
> NEW<br />
Bell 5180 Gauss/Tesla Meter<br />
bEL,5180 AU<br />
Magnetic measuring equipment, portable gaussmeter. built-in software<br />
eliminates the need for complex calibration procedures. Key features<br />
include Auto Zero, Min./Max./peak Hold, Auto Range and Relative Mode.<br />
Allows the user to select Gauss, Tesla or Ampere/Meter readings. With<br />
Hall effect transverse probe. Frequency bandwidth DC~30kHz, range up to<br />
30kG. Analogue output (±3V FS) and USb interface. battery operated.<br />
Arlyuna LF Milligauss Magnetic Field Strength Meter<br />
ARL,GM NZ<br />
Handheld ac magnetic field strength meter. Ranges 9.9mG & 99mG.<br />
Measurement bandwidth 12Hz~1.3KHz. 60Hz & 50Hz filter and analogue<br />
ac output for connection to oscilloscopes, recorders or loggers.<br />
Bell 4048 ac/dc Gauss Meter<br />
bEL,4048 NZ<br />
Handheld digital ac/dc Gauss/Tesla meter. Ranges are 200~20kGauss with<br />
a resolution of 0.1Gauss or 0.02~2Tesla with a resolution of 10E-6Tesla.<br />
Accuracy is 2% +2 digits. peak hold feature. Supplied with transverse probe<br />
and zero gauss chamber.<br />
Bell 4080 ELF Gaussmeter<br />
bEL,4080 AU<br />
Handheld digital ELF gaussmeter. Resolution 0.1mG. Auto ranging<br />
0.1~511mG. probe: 3 axis technology, maintains accuracy regardless of<br />
orientation. True rms measurement. Typical accuracy error: ±2%, +1 digit.<br />
Frequency response: ±5% 40~600Hz, -3db 25/1,000Hz. Applications<br />
include detecting magnetic field emissions from overhead ac power lines,<br />
video display terminals, office equipment and household appliances. This<br />
unit is not suitable for measuring field strength of “neodymium” or “rare earth”<br />
magnets or any permanent magnets. The frequency response ± 5% 40-<br />
600Hz and -3db 25/1000Hz.<br />
Bell 5080 Gauss/Tesla Meter<br />
bEL,5080 AU<br />
Portable gaussmeter complete with Hall effect transverse probe. Frequency<br />
bandwidth dc - 20kHz, ranges 300G~30kG. Max resolution 0.1G (10µT). Max<br />
and min hold. Analogue output and RS232 interface. battery operated.<br />
dc~10kHz 30 ~ 30,000<br />
bEL,4048 dc~12 200 ~ 20,000<br />
BEL,5080 dc~20kHz 300 ~ 30,000 Analog & RS232<br />
BEL,5180 dc~20kHz 300 ~ 30,000 Analog & USb port<br />
bEL,4090-20 Digital ELF gauss meter 40~400 0.1 ~ 1999mG<br />
Holaday HI-3627 Magnetic Field Meter<br />
HOL,HI-3627 AU<br />
Three orthogonal field sensors. Dynamic range 0.2mG~20G. True rms<br />
detection. Frequency range 5Hz~2kHz with an in-built 30Hz high pass filter.<br />
Meets requirements of the Swedish protocol and the IEEE p-1140 protocol.<br />
Holaday HI-3604 LF E & H Field Monitor<br />
HOL,HI-3604 AU/MY<br />
Low frequency field meter. Designed to evaluate electric and magnetic fields<br />
associated with 50Hz power lines. Frequency range 30~2,000Hz. Measures<br />
magnetic fields from 0.1 milligauss to 20 gauss. Measures electric fields from<br />
1 volt/meter to 200 kilovolts/meter. LCD display. 127 reading data memory.<br />
Meets the interim requirements of the Australian Radiation Laboratory for<br />
normal levels of AC power exposure.<br />
Hirst GM04 Microprocessor Controlled Gaussmeter<br />
HMI,GM04 AU<br />
Facilities: store and recall on 0~99 samples, hold. Analogue peak with<br />
digital storage. Auto and manual ranges. Automatic reading conversion<br />
between different units. (Note 1mT = 10G)<br />
Range 1: 0~to more than 3T resolution 1mT.<br />
Range 2: 0~299.9mT resolution 100µT.<br />
Range 3: 0~29.99mT resolution 10µT.<br />
Range 4: 0~2.999mT resolution 2µT.<br />
Accuracy (at 200C): ± 1%. Frequency range: dc and 15Hz~10kHz.<br />
Functions: dc, dc peak, ac rms, ac rms max, & ac peak. Applications include<br />
measurement of magnetic flux density of magnets and assemblies, electric<br />
motor air gaps and drive actuators.<br />
Hirst Magnetic Instruments GM04 Axial Probe<br />
HMI,GMO4AxIAL pRObE AU<br />
Axial probe for use with HMI,GM04.<br />
Teslatronics 70 milliGauss Meter<br />
TES,70 NZ<br />
Tri-axial ac magnetic field meter. Range is 0.1~1,999mGauss, accuracy is<br />
±1% at 60Hz. Frequency response is 40~400Hz ±10%, 50~300Hz ±5%,<br />
30~600Hz - 3db.<br />
Tri-axial Milligauss Magnetic Field Meter<br />
bEL,4090-20 NZ<br />
Handheld digital ELF gaussmeter. Resolution 0.1mG. Auto ranging,<br />
0.1~1999mG. Resolution 0.1mG in high-sensitivity mode & 1mG resolution<br />
in low-sensitivity mode. probe 3 axis technology, maintains accuracy<br />
regardless of orientation. True rms measurement. Typical accuracy error:<br />
±1% + 1 digit. Frequency response: ±10% 40~400Hz, -3db, 20/2000Hz.<br />
Applications include detecting magnetic field emissions from overhead<br />
ac power lines, video display terminals, office equipment and household<br />
appliances.