ELEC<strong>TR</strong>ICAL POWER<br />
50<br />
pOWer analySerS & recOrderS<br />
Dranetz-BMI Power Xplorer PX5<br />
DRA,px5 AU/NZ<br />
provides the full range of measurements include V, I, W, VA, VAR, TpF, DpF,<br />
Demand, Energy, Harmonics & Inter-harmonics, THD, Harmonics spectrum<br />
(V, I, W) to the 63rd, Flicker (pst, plt), Crest factor, K factor, transformer derating<br />
etc. Min/Max/Avg values are determined in ½ cycle RMS steps. Asset<br />
comes with ac flexible current clamp DRA-bMI,RR3035A/24, current range<br />
30/300/3,000A ac only. Can be extended to different ranges of measurement<br />
both ac & dc by selecting appropriate current clamps. High-speed transient<br />
capture (1MHz sampling rate) and the full range of arithmetic, vector and<br />
sequence parameters to evaluate distorted and un-balanced loads as<br />
defined in IEEE 1459. Exceeding high/low limits of any active parameter<br />
can trigger logging. Voltage & current disturbances can be triggered by<br />
peak value, wave-shape change & cycle-by-cycle RMS value change. preevent<br />
& post-event waveform capture cycles are user adjustable. Voltage<br />
& current channels can be cross-triggered. Suitable for both ac/dc power<br />
quality measurements. (Universal power Quality Analysers). DRA-bMI,px5<br />
analysers can be used for power quality measurements, current inrush<br />
(cycle-by-cycle current logging), fault recording (cycle-by-cycle voltage<br />
logging), long term monitoring and continuous logging at 1s intervals. Four<br />
differential voltages and current channels can be used independently. DRAbMI,px5<br />
is Class A compliant with IEC Standard 61000-4-30 ‘power Quality<br />
Measurement Methods’ (also AS DR04066), AS61000-4-7 ‘Harmonic &<br />
Inter-harmonic Measurements’ and AS61000-4-15 ‘Flicker-meter’. All data<br />
is collected at 256 samples/cycle/channel.<br />
Dranetz-BMI Power Xplorer PX5-400Hz<br />
DRA,px5-400 AU<br />
Specificaion as above but with 400Hz capability suitable for aviation and<br />
military use.<br />
Dranetz Current Clamp 1 - 30A 48Hz~10kHz<br />
DRA,<strong>TR</strong>2021 AU<br />
Set of 3 current clamps 1~30A RMS, 48Hz~10kHz. Max conductor size<br />
0.47”. Description as for DRA,pR6035A/36 current clamps above.<br />
Dranetz-BMI Power Guide 4400<br />
DRA,pG4400 AU/NZ<br />
provides the full range of measurements include V, I, W, VA, VAR, TpF, DpF,<br />
demand, energy, harmonics & inter-harmonics, THD, harmonics spectrum<br />
(V, I, W) to the 63rd, flicker (pst, plt), crest factor, K factor, transformer<br />
de-rating etc. Min/max/avg values are determined in ½ cycle RMS steps.<br />
Asset comes with ac flexible current clamp DRA-bMI,RR3035A/24, current<br />
range:- 30/300/3,000A ac only. Can be extended to different ranges of<br />
measurement ac/dc by selecting appropriate current clamps. Has the full<br />
range of arithmetic, vector and sequence parameters to evaluate distorted<br />
and un-balanced loads as defined in IEEE 1459. Exceeding high/low limits<br />
of any active parameter can trigger logging. Voltage & current disturbances<br />
can be triggered by peak value, wave-shape change & cycle-by-cycle RMS<br />
value change. pre-event & post-event waveform capture cycles are user<br />
adjustable. Voltage & current channels can be cross-triggered. Suitable for<br />
both ac/dc power quality measurements.(Universal power Quality Analysers).<br />
DRA-bMI,pG4400 analysers can be used for power quality measurements,<br />
current inrush (cycle-by-cycle current logging), fault recording (cycle-bycycle<br />
voltage logging), long term monitoring and continuous logging at 1s<br />
intervals. Four differential voltages and current channels can also be used<br />
independently. DRA-bMI,pG4400 is Class A compliant with IEC Standard<br />
61000-4-30 ‘power Quality Measurement Methods’ (also AS DR04066),<br />
AS61000-4-7 ‘Harmonic & Inter-harmonic Measurements’ and AS61000-4-<br />
15 ‘Flicker-meter’. All data is collected at 256 samples/cycle/channel.<br />
Dranetz Flexible Current Clamp 60/600/6,000A<br />
DRA,pR6035A/36 AU<br />
Set of 3 flexible current clamps 60/600/6,000A RMS, max conductor<br />
size/length of clamp is 36”. Current clamps are suitable for any of new<br />
Dranetz-bMI Models. DRA-bMI,pG4400 / DRA-bMI,px5 / DRA-bMI,px5-<br />
400. Current clamp/probe is very useful for current measurement through<br />
CT current transformer. CT Ratio can be selected on the new Dranetz-bMI<br />
above-mentioned models.<br />
Dranetz Current Clamp Probe 0~10A RMS<br />
DRA-bMI,<strong>TR</strong>2510 AU<br />
Set of 3 current clamps 0~10A RMS. Max conductor size 0.47”. Description<br />
as for DRA,pR6035A/36 current clamps above.<br />
Dranetz-BMI, 128 MB Flash Memory Card (Industrial Grade)<br />
DRA,128MbFMC AU/NZ<br />
Suitable for the following Dranetz -bMI Models:- DRA-bMI,px5, DRAbMI,px5-400,<br />
DRA-bMI,pG4400.