NEW<br />
Testo 635-2 Humidity, Temperature & Dewpoint Meter<br />
TES,635-2 AU<br />
portable humidity meter fitted with robust stainless probe with sintered filtercap<br />
for general or duct measurements to 120ºC, and fast-action K-type<br />
surface temperature probe. Displays relative humidity, absolute humidity,<br />
dew point, degree of humidity, enthalpy, temperature, and differential<br />
temperature (dewpoint~surface). Operating range 2~98%RH (±2%). Air<br />
temperature -20~120ºC (±0.2/0.5). Surface temperature -60~300ºC (±0.1).<br />
Internal memory for 10,000 values with USb interface, cable and software<br />
for download and presentation. Battery operated.<br />
Testo 635 Humidity & Dewpoint Meter<br />
TES,635 NZ/MY<br />
Temperature, humidity and dew point meter. Probe temperature range is<br />
-20~70ºC. Humidity range is 0~100%RH resolution: 0.1%, accuracy is ±2%.<br />
Dew point range is -50~40ºC.<br />
Testo 645 Humidity & Dewpoint Meter<br />
TES,645-1 AU<br />
portable humidity meter fitted with robust stainless probe for ambient work or<br />
duct measurements to 120OC. Displays relative humidity, absolute humidity,<br />
dew point, degree of humidity, enthalpy and temperature. Operating range<br />
2~98%RH [±2%], -20~120OC [±0.4/0.5]. battery operated.<br />
Abacus Hand-held Airborne Particle Counter<br />
AbA,301 AU<br />
Portable particle measuring system typically used in clean room applications.<br />
4 x fixed size channels 0.3, 0.5, 1.0 & 5.0micron. Count data automatically<br />
stored in a 500 sample memory which can be downloaded to a PC.<br />
Selectable sample time. Includes zero count filter for checking backgrounds.<br />
When used with included software will check clean rooms to ISO 14644 and<br />
BS5295 requirements. Battery operated.<br />
Vaisala WAA151 Wind Speed/Direction Transducer<br />
VAI,WAA151 AU<br />
Range 0.4~75m/s. Current output with selectable ranges including 4~20mA<br />
& 0~20mA. Requires indicator module such as DE,DT600 datalogger for<br />
indication of windspeed and direction.<br />
TSI 8551 Indoor Air Quality Monitor with Logging<br />
TSI,8551 AU<br />
Measures temperature, humidity, CO & CO concentrations. Humidity<br />
2<br />
5~95%RH, CO 0~500ppm, CO 0~5,000 ppm. Internal logging up to 63,000<br />
2<br />
data points; interval adjustable 1s~1h; RS232C interface and software<br />
included. Battery or mains operation.<br />
AUS<strong>TR</strong>ALIA<br />
1800 632 652<br />
www.techrentals.com.au<br />
NEW ZEALAND<br />
0800 832 473<br />
www.techrentals.co.nz<br />
air flOW meaSurement/air quality<br />
TSI Q-Trak plus Indoor Air Quality Monitor with Logging<br />
TSI,8554 AU/NZ<br />
Indoor air quality (IAQ) monitor for temperature and humidity measurements,<br />
CO and CO 2 concentrations. Humidity range 0~95%, temperature range<br />
0~50 O C. Electrochemical cell for CO 0~500ppm. NDIR cell for CO 2<br />
0~5000ppm. Data logging for 48,671 data points with interval adjustable<br />
1s~1h. Fitted with RS232 interface, and software included for download,<br />
storage and reporting. Battery or mains operation with ac adaptor.<br />
YES 205-5 Indoor Air Quality Monitor with Logging<br />
YES,205-5 AU<br />
5 channels for temperature, humidity, CO2, CO & NO. Temperature range<br />
0~50OC, resolution 0.1, accuracy ±0.5. Humidity 5~95 %RH, accuracy<br />
±2%. CO2 0~10,000 ppm, resolution 0.5ppm. CO 0~200 ppm, resolution<br />
0.5ppm. NO 0~300 ppm, resolution 0.5ppm. Logging of CO and NO allows<br />
checking of indoor air for contamination by vehicle emissions from nearby<br />
carparks, loading docks etc. Includes interface and software. Mains/battery<br />
operation.<br />
Casella Microtherm WBGT Area Heat Stress Monitor<br />
CAS,MICROTHERM AU<br />
portable area heat stress WbGT monitor with real-time graphical display.<br />
Measures heat stress potential [WbGT index] according to ISO7243. pRTD<br />
sensors with internal calibration-reference for wet-bulb, dry-bulb and globe<br />
temperatures. Large LCD display for numerical or graphical indication of<br />
temperatures and processed values for WbGT [indoor/outdoor plus TWA],<br />
relative humidity and dewpoint. Simple keypad/menu setup. Data logging<br />
for up to 32 separate runs and 49,100 records, with interval 30s~1h. RS232C<br />
port with included PC software for download and reporting or realtime<br />
display. Low water-level warning, and settable audible/visible WbGT alarm.<br />
Handheld, free-standing or tripod-mount. battery operated.<br />
TSI 8520 DustTrak Airborne Particle Monitor<br />
TSI,8520 AU/NZ<br />
Portable aerosol monitor. Laser photometer with 90O scattering detection,<br />
Range: 0.001~100mg/m3 [Calibrated for A1 test dust, ISO 121203-1],<br />
resolution: 1% of reading or 0.001; particle size range: 0.1~10µm. Internal<br />
pump flow rate 1.4~2.4L/min (1.7 nominal). Data logging 30,000 data points<br />
(21d @ 1min), log interval: 1s~1h. RS232C interface and software included.<br />
Battery operated.<br />
TSI 8520-1 Environmental Enclosure for DustTrak<br />
TSI,8520-1 AU<br />
Weatherproof outdoor housing for TSI,8520 aerosol monitor. Rugged case<br />
with tripod mount, fitted with sample inlet and water trap. Includes extendedlife<br />
battery pack and charger/adaptor.<br />
TSI 8525 P-Trak Ultrafine Particle Counter<br />
TSI,8525 AU<br />
Range 0.01~5 x 105 particles/cm3 . particle size range 0.02 to greater than<br />
1micron. Includes PC software and cable. Suitable for detection of ultrafine<br />
particles associated with pollutants. Battery powered [8h operation using<br />
alkaline batteries].<br />
AIR CONDITIONING & AIR QUALITY - HVAC & IAQ<br />
MALAYSIA<br />
603 5632 1135<br />