12.07.2015 Views

Instruction Manuals - Cole-Parmer

Instruction Manuals - Cole-Parmer

Instruction Manuals - Cole-Parmer

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Instruction</strong> Manual pH 1100/ 210010.1.2 mV setup submenusPress SETUP to enter setup mode. Use >/CAL toselect mV, and then press ENTER. Use the Δ/MI and∇/MR keys to scroll through submenus There are 5submenus (programs) in the mV setup mode:10.1.3 Ion setup submenus (pH 2100 only)Press SETUP to enter setup mode from the Ionmeasurement mode. Use >/CAL to select ion, and thenpress ENTER. Use the Δ/MI and ∇/MR keys to scrollthrough submenus. There are 7 submenus (programs)in the ion setup mode:mV Measurement AlarmSetup :P2.0-Sets low and high mV alarmsmV Meas. Al ar m : P2.0Press ENT. to Selectsee page 38Ion Unit Setup:P3.0-Selects Ion measurementunit(ppm, ppt, mg/L, g/L,mmol/L, mol/L)Ion Unit Setup :P3.0Press ENT. to Selectsee page 43mV Calibration Due AlarmSetup: P2.1-Sets calibration reminderalarm, select 1-365 days fromlast calibration datemVCalDue Al arm :P2.1Press ENT. to Selectsee page 39Ion Measurement AlarmSetup:P3.1-Sets low and high IonalarmsI on Me as . Al ar m: P3 .1Press ENT. t o Selectsee page 44Stability Setup:P2.2-Sets stability indicator criteria,off or on (high, medium or low)View mV CalibrationData:P2.3-Last mV calibration date/timemV offset valuemV Calibration Reset:P2.4-Clears all mV calibration dataSt abil i ty Set up:P2.2Pr es s ENT. t o Sel ec tsee page 40mV Ca l Da t a : P2 .3Pr es s ENT. t o Sel ec tsee page 41mV Ca l Re s e t : P2 .4Pr es s ENT. t o Sel ec tsee page 42Ion Calibration Due AlarmSetup:P3.2-Sets calibration reminderalarm, select 1-365 daysfrom last calibration dateStability Setup:P3.3-Sets stability indicatorcriteria, off or on (high,medium or low)Ion Mode Setup:P3.4-Selects between high or lowIon resolution mode (highhas ±500 mV value, low has±1850 mV value)I onCalDue Al ar m:P3.2Press ENT. to Selectsee page 45Stabilit y Set up:P3.3Press ENT. t o Selectsee page 46I on Mode Set up:P3.4Pr es s ENT. t o Sel ec tsee page 47View Calibration Data:P3.5-Last Ion calibrationdate/time. Calibration pointswith absolute mV valuesIon slopes (from low to highconcentration)I on Cal Data :P3.5Pr e s s ENT. t o Se l e c tsee page 48Ion Calibration Reset:P3.6-Clears all Ion calibrationdataI on Cal Reset :P3.6Pr e s s ENT . t o Se l e c tsee page 4928

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!