<strong>Instruction</strong> Manual pH 1100/ 210010.5.4 Data log setup mode P4.2Use this program select automatic or manual data logging.Automatic data logging can be set at timed intervals from 10seconds to 23 hours, 59 minutes, 59 seconds.1. Enter meter setup mode as described in steps 1-4 in Section10.5.1 Entering meter setup mode (page 50).2. Use Δ/MI key to scroll to program Data Log Setup: P4.2.See Figure 170.3. Press ENTER to enter program Data Log Setup: P4.2.Dat a Log Set up :P4.2Press ENT. to SelectFigure 170Dat a Log:Aut o ManualSel ec t & Pr es s ENTERFigure 1714. Press >/CAL key to toggle between Data Log Auto andManual. The selection will flash. See Figure 171.5. Press ENTER to confirm selection.• If you selected Auto, continue to step 6.• If you select Manual, pressing ENTER returns to the setupmode. Press Δ/MI key to continue to the next setupprogram, or press ∇/MR to go to the previous program.Press EXIT to return to measurement mode.Aut o Dat aLog PeriodHr : 1 Mi n : 3 0 Sec : 0Figure 1726. If you selected Auto in step 5, the display now reads AutoDataLog Period Hr: Min: Sec : Key in the time period(minimum of 10 seconds to maximum of 23 hours, 59 minutes,59 seconds) using the numeric keypad. If you make a mistake,use Δ/MI or ∇/MR keys to highlight mistake, then re-enter.See Figure 172.7. Press ENTER to confirm selection. The screen flashes SysUpdating... Please wait... and then returns to the setup mode.Press Δ/MI key to continue to the next setup program, orpress ∇/MR to go to the previous program. Press EXIT toreturn to measurement mode.10.5.5 Memory recall setup mode P4.3Use this program to select automatic or manual memory recall. Seepage 24 for more information on memory recall.1. Enter meter setup mode as described in steps 1-4 in Section10.5.1 Entering meter setup mode (page 50).2. Use Δ/MI key to scroll to program MemRecall Setup: P4.3.See Figure 173.3. Press ENTER to enter program MemRecall Setup: P4.3.MemRecall Set up:P4.3Press ENT. to SelectFigure 173Me mo r y Rec a l l Mo d eAuto ManualFigure 1744. Press >/CAL key to toggle between Memory Recall ModeAuto and Manual. The selection will flash. See Figure 174.5. Press ENTER to confirm selection and return to the setupmode. Press Δ/MI key to continue to the next setup program,or press ∇/MR to go to the previous program. Press EXIT toreturn to measurement mode.52

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!