Instruction Manuals - Cole-Parmer

Instruction Manuals - Cole-Parmer

Instruction Manuals - Cole-Parmer

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Instruction</strong> Manual pH 1100/ 210010.5 Meter general configuration setup mode10.5.1 Entering meter general setup mode1. Turn the meter ON. The meter setup mode can be enteredfrom any measurement mode—pH, mV or ion (pH 2100 meteronly).2. Press SETUP to enter the setup mode. The display will flashSetup Mode Activated, Please wait. ..See Figure 159.3. Use >/CAL to select "Meter". The mode selected will flash.See Figure 160, 161 and 162. Press ENTER to enter Metersetup mode. You are now in the Meter setup mode.4. The first setup program in Ion mode is Date/Time Setup: P4.0.See Figure 163. If you want to skip to another program, usethe Δ/MI and ∇/MR keys to scroll to the desired program.5. To exit the setup mode at anytime, press EXIT. The meterreturns to the measurement mode that it was in prior toentering meter setup mode.NOTE: To exit the setup mode at anytime without confirmingchanges, press EXIT. If you have made any changes to anyprograms and press EXIT, these changes will be confirmed. Toreset meter to default factory settings, see setup program MeterReset P4.7 (page 54).Setup Mode ActivatedPl e as e wa i t . . .Figure 159Set up:pH/ Temp Met erSelect & Press ENTERFigure 160Setup: mV MeterSel ec t & Pr es s ENTERFigure 161Setup: Ion MeterSel ec t & Pr es s ENTERFigure 16210.5.2 Date/time setup mode P4.0Use this program to set the meter date and time.1. Enter the Meter setup mode as described above in Section10.5.1 Entering meter general setup mode (Pg 50). The firstsetup mode is Date/Time Setup: P4.0. See Figure 163.2. Press ENTER to enter program Date/Time Setup: P4.0.3. Key in the Date, Month, Year, Hr and Min using the numerickeypad. Use the >/CAL key or the ENTER key to toggle to eachfield. If you make a mistake keying the value, use the Δ/MI and∇/MR keys to highlight mistake, then re-enter.See Figure 164.4. After keying in a value for the last field (Min), press ENTER toconfirm. The screen flashes Clock Updating, Please wait. . SeeFigure 165. The clock then flashes the date and time.See Figure 166.Press Δ/MI key to continue to the next setup program, or press∇/MR to go to the previous program. Press EXIT to return to themeasurement mode you were in prior to entering meter setupmode.Dat e/ Ti me Set up: P4.0Pr es s ENT. t o Sel ec tFigure 163Dat e:23 Mont h:01Year:02 Hr:8 Min:07Clock Updat ingPl eas e wai t . . .Figure 164Figure 165DateTimeJan 23 2002 08”07:31Figure 16650

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!