12.07.2015 Views

eWON General Reference Guide - Esco Drives & Automation

eWON General Reference Guide - Esco Drives & Automation

eWON General Reference Guide - Esco Drives & Automation

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>General</strong> <strong>Reference</strong> <strong>Guide</strong>IO Servers Configuration5.10 EWON IO Server5.10.1 IntroductionThe <strong>eWON</strong> IO server is used to interface the <strong>eWON</strong> INPUTS and OUTPUTS.Depending on your <strong>eWON</strong> model, you have:• Digital inputs1 on <strong>eWON</strong>500/2001/40019 on <strong>eWON</strong>4002• Digital outputs1 on <strong>eWON</strong>500/2001/40013 on <strong>eWON</strong>4002• Analog inputsNone on <strong>eWON</strong>500/2001/40016 on <strong>eWON</strong>4002Additionally, there are a number of Tags that can be addressed with this IO server and which are computed by the <strong>eWON</strong> IO Server.These additional Tags are used for energy management. In Energy management, the following requirements are taken into accounts:• Using digital inputs as counter inputs• Count for a given interval and latch computed result (also save it in historical)• Reject the measurement interval if too long or too short• Adjust the <strong>eWON</strong>’s Real Time Clock based on a digital inputThese Tags will be computed if the energy module is enabled.There is no topic name to define for the <strong>eWON</strong> IO server.5.10.2 Standard <strong>eWON</strong> I/O Item Names5.10.2.1 Tag name conventionThe following Tags are available for standard <strong>eWON</strong> Inputs & Outputs access:IO Server configurationCommentIO Server NameTopic NameEWONEmptyItem Name DI# Digital Input (1) BooleanCI# Counter Input (1) 0 to 2.147.400.000(2) AnalogFI# Counter Input 0 to 255 AnalogLI# Latched Counter Input (1) AnalogDO# Digital Output (1) BooleanAI# Analog Input (1) AnalogBI# Button Input (1) BooleanTable 94: <strong>eWON</strong> IO server configuration parameters - no topic definedNOTE:The button input (BI1) can be used during normal <strong>eWON</strong> operations, if it is pressed for more than 4 seconds while the <strong>eWON</strong> isbooting, the flash file system will be erased (please refer to chapter “Resetting the <strong>eWON</strong>” on page 201).(1) The number of items depends of the <strong>eWON</strong> type. See Table 96 on page 118.(2) From firmware 4.1S3 to 4.3, the CIx value wrapped at 1.000.000. Before 4.1S3, the CIx was misinterpreted as negative whenvalue passes over 2 31 .RG-001-0-EN ver 1.5 <strong>eWON</strong>® - 20/03/2009 - ©ACT'L sa Page 117

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!