12.07.2015 Views

eWON General Reference Guide - Esco Drives & Automation

eWON General Reference Guide - Esco Drives & Automation

eWON General Reference Guide - Esco Drives & Automation

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>General</strong> <strong>Reference</strong> <strong>Guide</strong>IO Servers Configuration5.12 S7-300&400 (MPI/Profibus - ISOTCP)5.12.1 IntroductionS73&400 IO Server is dedicated to communicate directly with SIEMENS PLC (S7-300 & S7-400).The <strong>eWON</strong> will connect directly to the PLC’s MPI interface or Profibus DP interface.WARNING: The MPI/Profibus interface requires a special serial port hardware!ONLY the <strong>eWON</strong>s MPI/Profibus are able to communicate in MPI/Profibus<strong>eWON</strong> product codes like EWxxx6x (i.e.: EW41264 <strong>eWON</strong>4001 MPI with pstn modem)<strong>eWON</strong>s MPI/Profibus have a Serial Gender-Changer fixed on DB9 connector to provide female DB9connector.<strong>eWON</strong>s MPI/Profibus have a coloured (in light blue) square around DB9 connector labelized MPI (see photoon right).Others Serial IO Server (i.e.: PPI, modbus RTU) are not available on <strong>eWON</strong> MPI/Profibus.The ISOTCP (Ethernet) is available on all <strong>eWON</strong> types.With an <strong>eWON</strong>500 (with a standard Serial Port), you can have access to a S7-300&400 Siemens PLC by Ethernet thanksto the ISOTCP protocol.With an <strong>eWON</strong>500-MPI, you can have acces by the MPI port and by ISOTCP to your S7-300&400, if it has both interfaces.Multi-Session: Since firmware 5.4, the ISOTCP-MPI gateway allows multiple clients to access the same PLC at the same time.PPI MultiMaster (for S7-200): Since firmware 5.5, it is supported by the MPI port of the <strong>eWON</strong> (See “S7-200 (PPI - ISOTCP)” on page 130)5.12.2 Setup5.12.2.1 COM configurationFigure 96: MPI link configurationParameterGateway MPI/ProfibusDestination NodeProtocol TypeDescriptionIdentifies the PLC MPI/Profibus Destination address when ISOTCP is usedSelect protocol MPI or PROFIBUS.As the MPI port configuration is shared by the S73&400 and the S7-200IOServers, this combo box shows also the PPI MULTIMASTER protocol (See“S7-200 (PPI - ISOTCP)” on page 130)PPI MultiMaster and MPI/Profibus are mutually exclusive. It is not allowed touse the S7-200 and the S73&400 IOServers on the MPI port at the same time.Figure 97: MPI/Profibus settingsRG-001-0-EN ver 1.5 <strong>eWON</strong>® - 20/03/2009 - ©ACT'L sa Page 125

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!