12.07.2015 Views

eWON General Reference Guide - Esco Drives & Automation

eWON General Reference Guide - Esco Drives & Automation

eWON General Reference Guide - Esco Drives & Automation

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>General</strong> <strong>Reference</strong> <strong>Guide</strong>IO Servers Configuration<strong>eWON</strong>4002<strong>eWON</strong>4102DI1... DI8CI1... CI8LI1... LI8DI9CI9LI9DO1... DO2DO3BI1Status of input 1 to 8 on connector DI1-DI8 (top side)Counter on input 1 to 8 on connector DI1-DI8 (top side)Latched counter on input 1 to 8 on connector DI1-DI8 (top side)Status of input 9 on connector Input/output (bottom side)Counter on input 9 on connector Input/output (bottom side)Latched counter on input 9 on connector Input/output (bottom)Digital command of relay 1 and 2 on relay connector (bottom side)Digital command of output 1 on connector Input/output (bottom)Status of button (reset) on the front faceAI1... AI4 Value of analog input 1 to 4AI5... AI6Value of analog input 5 to 6 (PT100 probes)Table 96: Available Items for <strong>eWON</strong> product type5.10.2.2 Energy configuration with the LIx TagsThe following parameters can be added to the <strong>eWON</strong> IO server in order to activate the energy support (enter Energy:1, validate and the otherparameters will be automatically added):ParameterDefaultValueEnergy 0 or 1 Enabled or notOnce Energy is defined, the <strong>eWON</strong> will automatically add the other parameters withdefault value.When 0, no energy computation at all are performed, saving <strong>eWON</strong> CPU resources.Debug 0 or 1Not automaticalyaddedWhen :1 all synchonisations are logged in the Real time event log.RefTimeThis is the reference time to compute interval. Letting this empty will start at 1/1/1970 00:00. You may entera date with hour in the form 08/07/2002 11:15:00 to set a new reference (usually not required).IntTime 15 This is the integration time in MINUTES.IntTolS 5SyncIO 5SyncTolS 5This is a tolerance on the integration time in SECONDS. If the measurment interval is shorter or longer thanthis number of seconds, the period is considered as valid. For example IntTime=15 IntTolS =5 means"interval is valid if between 11.14:55 and 11.15:05".This is the IO number for clock synchronization. 0 means no synchro available, 1..8 is the IO number.Synchonisation is based on the counter input associated with the digital input, each time the IO changes the<strong>eWON</strong> will try to perform a synchronization (see also SyncTolS)This is the tolerance for accepting the synchronization pulse in SECONDS.If the synchronization pulse arrives outside the interval, the pulse is rejected. ERROR REPORT: the firsttime the pulse is rejected, an error is logged in the event log. Next errors are not logged (except in Real timelog if Debug is enabled); When sync are accepted again, a trace is logged in the event file for the firstaccepted synchonization.REM: Because the internal clock has a precision of 1 second, the time is only updated if the absolute valueof the offset is greater than 1 (2 or more). Otherwise the offset jitters between -1 and +1 all the time.Figure 90: Energy IO server parametersRG-001-0-EN ver 1.5 <strong>eWON</strong>® - 20/03/2009 - ©ACT'L sa Page 119

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!