Symbols7.5.7. AlarmUse this symbol to indicate an alarm condition.If an alarm condition occurs, this symbol that actively flashes. If configured, this symbolplays a continuous audbile tone until the alarm is muted or acknowledged:Toolbar Icon:Symbol Image:Table 7–38. Alarm Symbol User-Defined AttributesAttribute Description Possible Entries DefaultSymbol ID ID number of the symbol Set ByApplicationType Generic type DirectionIndicatorLabel Text label of symbol Any Text(128 char. max)Symbol ID + "Gn"Color (Inactive)AudbileActive StateActive LabelLabel LocationSelect separate colors foractive and inactive statesof alarm symbol.Select an audible tone forthe alarm symbol when inthe active state.The state (True or False)that defines when thealarm is active.The label text displayedwhen the alarm is active.Select where the symbol’slabel appears in relation tothe symbol.See listNone, BeepTrue, FalseAny Text(128 char. max)Left, Top, Bottom,Center, RightDescription Optional text description Optional, Any Text(255 char. max)Red (inactive)Green (active)NoneTrueBlankRight""P2528, Rev. Aug/12 7–31 Alstom <strong>Signaling</strong> <strong>Inc</strong>.