Ultrasonic milk analyzer6. MAKING CORRECTIONS AND RECALLIBRATION OF THEDEVICEIn the process of work with the analyser there is a possibility the results tostart differing between the data <strong>for</strong> some of the measuring parameters whenmeasured with the milk analyzer and the corresponding reference method ofanalyses (Gerber <strong>for</strong> fat, Kjeldhal <strong>for</strong> proteins etc). In order to establish thepossible discrepancy and to correct the readings of the milk analyser do thefollowing:6.1. Taking samples and preparation of samples <strong>for</strong> checking theaccurracy of the milk analyser, making corrections andrecalibrationThis is a basic moment <strong>for</strong> the correct checking the accuracy of the analyserand <strong>for</strong> making correct and precise correction and calibration. It isac<strong>com</strong>plished according Appendix Sampling and preparation of samples <strong>for</strong>verification the accuracy of the milk analyzer, making corrections andrecalibration.6.2. Determination the type of the discrepancy:6.2.1. Making measurementsMake measurements with different samples (not less than 3) with knownvalues of a separate parameter (<strong>for</strong> example fat content), determined by theknown reference methods of analyses (<strong>for</strong> example Gerber's method <strong>for</strong>determination of fat content). For more accuracy it is re<strong>com</strong>mended amongthese samples to be also such with values, close to the lowest and highestbounds <strong>for</strong> the measured parameters.Make 5-time measurement <strong>for</strong> each of the samples. Calculate the averagevalue <strong>for</strong> each sample parameter, without taking into consideration the firstmeasurement <strong>for</strong> each sample.6.2.2. Analysing the measurement resultsMake <strong>com</strong>parison between the values of the parameter from the referencesample and measured with the analyser. Make analyses of the differencereceived.6.2.2.1. If the received differences are relatively constant value <strong>for</strong> sampleswith different content of the analysed parameter, it is necessary to makecorrection.<strong>Operation</strong> manual 25/98

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!