5.4 Suitable specimen casting mold with .55 inches (14 mm) depth and 9.8 - 9.9 inches<br />

(250-252 mm) inside diameter. A raised lip mold is preferred but a flat surface polymethyl<br />

methacrylate or equivalent mold is satisfactory.<br />

5.5 Mold strike-off apparatus, such as a wooden dowel, with minimum dimensions: 0.78<br />

- 17.7 inches (20 mm diameter by 450 mm long).<br />

5.6 Scales, with capacity of 2000.0 g, accurate to +/- 0.1 g.<br />

5.7 Wooden prop block or device to support the pan and mounting plate assembly<br />

during the test.<br />

5.8 Suitable rust-resistant mixing containers and spoons. Additionally, plate removal<br />

device with tapered flat tip (for example, a paint can lid opening tool), as pictured in Figure B.2,<br />

is needed for carefully placing and removing specimen plates into and from the abrasion pan.<br />

Figure B.2: Plate Removal Device<br />

5.9 Constant temperature water bath controlled at specified temperatures.<br />

5.10 Absorbent paper towels, single fold, CS Scott or equivalent.<br />