Max Alarm 20<br />
Max PreAlarm 21<br />
Min Alarm 22<br />
The max alarm level has been<br />
reached.<br />
The max pre alarm level has been<br />
reached.<br />
The min alarm level has been<br />
reached.<br />
Min PreAlarm 23<br />
The min pre alarm Level has been<br />
reached.<br />
LY 24 Logic output Y.<br />
!LY 25 Logic output Y inverted.<br />
LZ 26 Logic output Z.<br />
!LZ 27 Logic output Z inverted.<br />
CA 1 28 Analogue comparator 1 output.<br />
!A1 29 Analogue comp 1 inverted output.<br />
CA 2 30 Analogue comparator 2 output.<br />
!A2 31 Analogue comp 2 inverted output.<br />
CD 1 32 Digital comparator 1 output.<br />
!D1 33 Digital comp 1 inverted output.<br />
CD 2 34 Digital comparator 2 output.<br />
!D2 35 Digital comp 2 inverted output.<br />
Operation 36<br />
Run command is active or VSD running.<br />
The signal can be used to control<br />
the mains contactor if the VSD is<br />
equipped with Standby supply option.<br />
T1Q 37 Timer1 output<br />
!T1Q 38 Timer1 inverted output<br />
T2Q 39 Timer2 output<br />
!T2Q 40 Timer2 inverted output<br />
Sleeping 41 Sleeping function activated<br />
Crane Deviat 42 Tripped on deviation<br />
PumpSlave1 43 Activate pump slave 1<br />
PumpSlave2 44 Activate pump slave 2<br />
PumpSlave3 45 Activate pump slave 3<br />
PumpSlave4 46 Activate pump slave 4<br />
PumpSlave5 47 Activate pump slave 5<br />
PumpSlave6 48 Activate pump slave 6<br />
PumpMaster1 49 Activate pump master 1<br />
PumpMaster2 50 Activate pump master 2<br />
PumpMaster3 51 Activate pump master 3<br />
PumpMaster4 52 Activate pump master 4<br />
PumpMaster5 53 Activate pump master 5<br />
PumpMaster6 54 Activate pump master 6<br />
All Pumps 55 All pumps are running<br />
Only Master 56 Only the master is running<br />
Loc/Rem 57 Local/Rem function is active<br />
Standby 58 Standby supply option is active<br />
PTC Trip 59 Trip when function is active<br />
PT100 Trip 60 Trip when function is active<br />
Overvolt 61 Overvoltage due to high main voltage<br />
Overvolt G 62 Overvoltage due to generation mode<br />
Overvolt D 63 Overvoltage due to deceleration<br />
Acc 64 Acceleration along the acc. ramp<br />
Dec 65 Deceleration along the dec. ramp<br />
I 2 t 66 I 2 t limit protection active<br />
V-Limit 67 Overvoltage limit function active<br />
C-Limit 68 Overcurrent limit function active<br />
Overtemp 69 Over temperature warning<br />
Low voltage 70 Low voltage warning<br />
DigIn 1 71 Digital input 1<br />
DigIn 2 72 Digital input 2<br />
DigIn 3 73 Digital input 3<br />
DigIn 4 74 Digital input 4<br />
DigIn 5 75 Digital input 5<br />
DigIn 6 76 Digital input 6<br />
DigIn 7 77 Digital input 7<br />
DigIn 8 78 Digital input 8<br />
ManRst Trip 79<br />
Active trip that needs to be manually<br />
reset<br />
Com Error 80 Serial communication lost<br />
External Fan 81<br />
The VSD requires external cooling.<br />
Internal fans are active.<br />
LC Pump 82 Activate liquid cooling pump<br />
LC HE Fan 83<br />
Activate liquid cooling heat exchanger<br />
fan<br />
LC Level 84 Liquid cooling low level signal active<br />
Run Right 85<br />
Communication information<br />
Positive speed (>0.5%), i.e. forward/<br />
clockwise direction.<br />
Run Left 86<br />
Negative speed (0.5%), i.e. reverse<br />
counter clockwise direction.<br />
Com Active 87 Fieldbus communication active.<br />
Brk Fault 88 Tripped on brake fault (not released)<br />
BrkNotEngage 89<br />
Warning and continued operation<br />
(keep torque) due to Brake not<br />
engaged during stop.<br />
Modbus Instance no/DeviceNet no: 43271<br />
Profibus slot/index 169/175<br />
Fieldbus format<br />
UInt<br />
Modbus format<br />
UInt<br />
Omron SX inverter manual Functional Description 127