USER’S MANUAL
Omron SX inverter manual
Omron SX inverter manual
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Trip menu Copied from Description<br />
81I 728 I/O status option board 1<br />
81J 729 I/O status option board 2<br />
81K 72A I/O status option board 3<br />
81L 731 Run Time<br />
81M 732 Mains Time<br />
81N 733 Energy<br />
81O 310 Process reference<br />
Communication information<br />
Modbus Instance no/DeviceNet no: 31102 - 31135<br />
Profibus slot/index<br />
Fieldbus format<br />
Modbus format<br />
Example:<br />
Fig. 98 shows the third trip memory menu [830]: Over<br />
temperature trip occurred after 1396 hours and 13<br />
minutes in Run time.<br />
Fig. 98 Trip 3<br />
121/246 - 254,<br />
122/0 - 24<br />
Depends on parameter,<br />
see respective parameter.<br />
Depends on parameter,<br />
see respective parameter.<br />
830 Over temp<br />
Stp 1396h:13m<br />
11.8.2 Trip Messages [820] - [890]<br />
Same information as for menu [810].<br />
Communication information<br />
Modbus Instance no/<br />
DeviceNet no:<br />
Profibus slot/index<br />
Fieldbus format<br />
Modbus format<br />
31151–31185<br />
31201–31235<br />
31251–31285<br />
31301–31335<br />
31351–31385<br />
31401–31435<br />
31451–31485<br />
31501–31535<br />
122/40–122/74<br />
122/90–122/124<br />
122/140–122/174<br />
122/190–122/224<br />
122/240–123/18<br />
123/35 - 123/68<br />
123/85–123/118<br />
123/135–123/168<br />
Trip log list<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
Trip log list<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
Depends on parameter, see respective<br />
parameter.<br />
Depends on parameter, see respective<br />
parameter.<br />
All nine alarm lists contain the same type of data. For<br />
example DeviceNet parameter 31101 in alarm list 1<br />
contains the same data information as 31151 in alarm<br />
list 2. It is possible to read all parameters in alarm lists<br />
2–9 by recalculating the DeviceNet instance number<br />
into a Profibus slot/index number. This is done in the<br />
following way:<br />
slot no = abs((dev instance no-1)/255)<br />
index no = (dev instance no-1) modulo 255<br />
dev instance no = slot nox255+index no+1<br />
Example: We want to read out the process value out<br />
from alarm list 9. In alarm list 1 process value has the<br />
DeviceNet instance number 31102. In alarm list 9 it<br />
has DeviceNet instance no 31502 (see table 2 above).<br />
The corresponding slot/index no is then:<br />
slot no = abs((31502-1)/255)=123<br />
index no (modulo)= the remainder of the division<br />
above = 136, calculated as: (31502-1)-123x255=136<br />
11.8.3 Reset Trip Log [8A0]<br />
Resets the content of the 10 trip memories.<br />
8A0 Reset Trip<br />
Stp<br />
No<br />
Default:<br />
No 0<br />
Yes 1<br />
No<br />
Omron SX inverter manual Functional Description 147