V1.000, 10.2011<br />

<strong>MDrive</strong>Plus <strong>EtherNet</strong>/<strong>IP</strong> 11 Service, maintenance and disposal<br />

11 Service, maintenance and disposal<br />

Integrated <strong>Motion</strong> System<br />

DAMAGE TO SYSTEM COMPONENTS AND LOSS OF CON-<br />

TROL<br />

Interruptions of the negative connection of the controller supply<br />

voltage can cause excessively high voltages at the signal connections.<br />

• Do not interrupt the negative connection between the power<br />

supply unit and load with a fuse or switch.<br />

• Verify correct connection before switching on.<br />

• Do not connect the controller supply voltage or change its<br />

wiring while the is supply voltage present..<br />

Failure to follow these instructions can result in injury or<br />

equipment damage.<br />

RISK OF INJURY WHEN REMOVING CIRCUIT BOARD PLUGS<br />

• When removing them note that the connectors must be<br />

unlocked.<br />

11<br />

– Supply voltage VDC: unlock by removing locking screws<br />

– I/O interface: unlock with locking tabs<br />

• Always hold the plug to remove it (not the cable).<br />

Failure to follow these instructions can result in injury or<br />

equipment damage.<br />

The product may only be repaired by a certified customer service center.<br />

No warranty or liability is accepted for repairs made by unauthorized<br />

persons.<br />