TT CME Gateway System Administration Manual - Trading ...
TT CME Gateway System Administration Manual - Trading ...
TT CME Gateway System Administration Manual - Trading ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
5 Configuring Order Management<br />
Example: [location] in an<br />
Upgraded Hostinfo.cfg<br />
File<br />
<strong>CME</strong> <strong>Gateway</strong> <strong>System</strong> <strong>Administration</strong> <strong>Manual</strong> 103<br />
<strong>Trading</strong> Technologies International, Inc.<br />
The following example shows [location] correctly added and configured before<br />
[order_session_1] at the top of the hostinfo.cfg file.<br />
Example:<br />
## Global section Location is mandatory and applies to all the order<br />
Sessions on the <strong>Gateway</strong>.<br />
## Within the Location section:<br />
## i) a mandatory parameter named Country is required and should be the 2<br />
character country code per ISO 3166-1.<br />
## ii) an optional parameter named StateProvince. if provided, it has to<br />
be 2 characters.<br />
##<br />
## For example,<br />
##<br />
## [location]<br />
## Country=US<br />
## StateProvince=IL<br />
##<br />
## [location]<br />
## Country=GB<br />
[location]<br />
Country=US<br />
StateProvince=IL<br />
[order_session_1]<br />
Member=TR409<br />
Password=TR4<br />
iLinkPrimaryIP=10.140.120.45<br />
iLinkPrimaryPort=11092<br />
A1=40<br />
G1=30<br />
G2=40<br />
M1=10<br />
M2=21<br />
P1=10<br />
P2=21<br />
U1=10<br />
Upgrading <strong>TT</strong> Clients When upgrading <strong>TT</strong> Client applications to support the mandatory iLink Tags, you<br />
can upgrade to the minimum supported versions independently of when the <strong>CME</strong><br />
<strong>Gateway</strong> is upgraded. The timing of the <strong>TT</strong> Client upgrades should be based on<br />
the needs of your trading environment.<br />
The following table lists the <strong>TT</strong> Client versions required for supporting mandatory<br />
iLink tags in your trading environment, and describes their impact on the <strong>CME</strong><br />
<strong>Gateway</strong>.