3 Configuring Global Settings<br />

Telnet Tests <strong>CME</strong> Group distributes two order IP addresses and two price IP addresses, each<br />

set with its associated ports. <strong>TT</strong> recommends that you telnet these locations to<br />

test their status (respectively labeled IPAddress and Port in the procedure below).<br />

<strong>CME</strong> Group usually sends this information via E-mail to the customer.<br />

To telnet <strong>CME</strong> Group:<br />

1. Open a command window.<br />

2. Type: telnet IPAddress Port<br />

3. Type: telnet IPAddress Port<br />

The telnet test fails if you receive a Connection Failed prompt box.<br />

Example:<br />

<strong>TT</strong> Listen Tool The <strong>TT</strong> FAST Listen (named tt_fast_listen.exe and available in Version 7.5 and<br />

higher) tool listens to the price data that the <strong>CME</strong> Group sends. You use this tool<br />

to display the price data as plain text messages instead of .<br />

The tool exists in the :tt\Exchange-Flavor directory.<br />

Because the tool receives price data before the Price Server processes it, you can<br />

use it as a troubleshooting tool to compare actual price messages against what<br />

the Price Server broadcasts.<br />

<strong>CME</strong> Group Feed Tests You must perform the <strong>CME</strong> Group Feed tests to verify the status of both <strong>CME</strong><br />

Group’s MDP feeds. You can perform these tests only during normal <strong>CME</strong> Group<br />

trading hours when the exchange is actively distributing price data. The <strong>CME</strong><br />

Group delivers data via two MDP data channels named Feed A and Feed B. Failure<br />

to receive both feeds can result in excessive history requests and can cause price<br />

freezes.<br />

You must pass both tests to maintain a proper connection to the exchange.<br />

To test FIX/FAST Feed:<br />

1. Open a command window.<br />

2. Type: :\tt\Exchange-Flavor<br />

3. Type the following exactly as indicated taking particular note on spacing:<br />

tt_fast_listen –config :\tt\ -template<br />

:\tt\config\FAS<strong>TT</strong>emplates.xml<br />

-address 224.0.26.5:10005 –interface IP<br />

where is the local drive letter and IP is the IP address of the <strong>TT</strong><br />

<strong>Gateway</strong> that faces the exchange.<br />

This tests the Feed A connection for the FX_FUTURES channel. If the test<br />

succeeds, various messages appear in the command window. If you do not<br />

receive messages on either one of these channels, please contact the <strong>CME</strong><br />

Group GCC.<br />