3 Configuring Global Settings<br />
Telnet Tests <strong>CME</strong> Group distributes two order IP addresses and two price IP addresses, each<br />
set with its associated ports. <strong>TT</strong> recommends that you telnet these locations to<br />
test their status (respectively labeled IPAddress and Port in the procedure below).<br />
<strong>CME</strong> Group usually sends this information via E-mail to the customer.<br />
To telnet <strong>CME</strong> Group:<br />
1. Open a command window.<br />
2. Type: telnet IPAddress Port<br />
3. Type: telnet IPAddress Port<br />
The telnet test fails if you receive a Connection Failed prompt box.<br />
Example:<br />
<strong>TT</strong> Listen Tool The <strong>TT</strong> FAST Listen (named tt_fast_listen.exe and available in Version 7.5 and<br />
higher) tool listens to the price data that the <strong>CME</strong> Group sends. You use this tool<br />
to display the price data as plain text messages instead of .<br />
The tool exists in the :tt\Exchange-Flavor directory.<br />
Because the tool receives price data before the Price Server processes it, you can<br />
use it as a troubleshooting tool to compare actual price messages against what<br />
the Price Server broadcasts.<br />
<strong>CME</strong> Group Feed Tests You must perform the <strong>CME</strong> Group Feed tests to verify the status of both <strong>CME</strong><br />
Group’s MDP feeds. You can perform these tests only during normal <strong>CME</strong> Group<br />
trading hours when the exchange is actively distributing price data. The <strong>CME</strong><br />
Group delivers data via two MDP data channels named Feed A and Feed B. Failure<br />
to receive both feeds can result in excessive history requests and can cause price<br />
freezes.<br />
You must pass both tests to maintain a proper connection to the exchange.<br />
To test FIX/FAST Feed:<br />
1. Open a command window.<br />
2. Type: :\tt\Exchange-Flavor<br />
3. Type the following exactly as indicated taking particular note on spacing:<br />
tt_fast_listen –config :\tt\ -template<br />
:\tt\config\FAS<strong>TT</strong>emplates.xml<br />
-address 224.0.26.5:10005 –interface IP<br />
where is the local drive letter and IP is the IP address of the <strong>TT</strong><br />
<strong>Gateway</strong> that faces the exchange.<br />
This tests the Feed A connection for the FX_FUTURES channel. If the test<br />
succeeds, various messages appear in the command window. If you do not<br />
receive messages on either one of these channels, please contact the <strong>CME</strong><br />
Group GCC.<br />
56 <strong>CME</strong> <strong>Gateway</strong> <strong>System</strong> <strong>Administration</strong> <strong>Manual</strong><br />
<strong>Trading</strong> Technologies International, Inc.