3<br />

Initial Configuration<br />

<strong>CME</strong> <strong>Gateway</strong> <strong>System</strong> <strong>Administration</strong> <strong>Manual</strong> 47<br />

<strong>Trading</strong> Technologies International, Inc.<br />

Configuring Global Settings<br />

Time and Time Zone Due to the default settings in its configuration files, <strong>TT</strong> recommends that you set<br />

the <strong>TT</strong> <strong>Gateway</strong> to run in the CST time zone (Chicago time) with Daylight Savings<br />

enabled.<br />

If you decide to run the <strong>CME</strong> <strong>Gateway</strong> in another time zone, you must:<br />

• Run the <strong>CME</strong> <strong>Gateway</strong> in the correct time zone and daylight savings setting<br />

associated with that time zone.<br />

• Adjust the times in ttchron.ini to match the time in which the <strong>CME</strong><br />

<strong>Gateway</strong> runs.<br />

• Adjust times in Fill Server section of the aconfig_local.xml file.<br />

Aconfig Time Zone<br />

Parameters<br />

You must pay close attention when configuring the time zone settings located in<br />

the Aconfig.Core.Server.Exchange-Specific.Exchange-flavor.Time.Zone<br />

directory. These settings directly impact price and fill server operation.<br />

When resetting these parameters, you must restart both the Price and Fill<br />

Servers.<br />

Account Names The <strong>CME</strong> Group restricts account names to a maximum length of 12 characters.<br />

For longer account names, the exchange truncates any additional characters<br />

beyond the 12 character limit. This results in orders being rejected by the<br />

exchange.<br />

Member, Group, and<br />

Trader ID Format<br />

Example:<br />

<strong>Trading</strong> Firm ABC based in Indianapolis decides to run the <strong>CME</strong> <strong>Gateway</strong> in the Indiana<br />

time zone. ABC sets the system clock to Indiana time, which is CST, and turns off<br />

daylight savings. Whenever Daylight Savings changes, ABC edits ttchron.ini to account<br />

for new time schedules.<br />

Warning: You must restart the Price and Fill Servers after changing<br />

the time settings in the aconfig_local.xml file.<br />

Warning: Failure to restart the Price and Fill Servers after changing the Aconfig time<br />

zone setting can result in missing fills.<br />

Warning: Users must use account numbers that do not exceed 12 characters in<br />

length. If your account name exceeds the 12 character limit, <strong>CME</strong> Group will prevent<br />

you from sending orders to the exchange.<br />

<strong>TT</strong> Trader IDs on <strong>CME</strong> <strong>Gateway</strong>s use the format SessionIdFirmIdxxxyyy, where:<br />

• The <strong>CME</strong> Group determines the values of SessionId and FirmId. Trader’s<br />

use this concatenation as their Member ID when logging into X_TRADER®.<br />

• To better manage trader groups, if the customer wants to use a custom<br />

FirmID, they may do so. However, the customer must communicate this to

Hooray! Your file is uploaded and ready to be published.