A Configuration Parameters<br />

• [order_session_1]<br />

• [order_session_2]<br />

The first section in hostinfo.cfg does not include the _# identifier.<br />

Whenever a trader submits an order, that trader’s Member ID determines which<br />

order session carries the order. The Member ID maps to the order session’s<br />

member parameter.<br />

The table below includes the parameters that you use with the [order_session_#]<br />

section. Default values are included when applicable.<br />

Warning: You must cancel all working orders before altering or removing any iLink<br />

session information. Failure to do so can result in orders becoming lost or deleted<br />

from the <strong>CME</strong> <strong>Gateway</strong>.<br />

Parameter Description<br />

[order_session_#] This is the section title, where # uniquely identifies the order<br />

session.<br />

Member=SessionIDFirmID Also called the Member ID. This is a concatenation of the<br />

customer’s FirmID and SessionID, both of which <strong>CME</strong> Group<br />

assigns to the customer. This parameter has only six alphanumeric<br />

characters.<br />

Each [order_session_#] section must have a unique Member<br />

parameter.<br />

Warning: If there is a duplicate Member parameter<br />

configured on a multi-session <strong>CME</strong> <strong>Gateway</strong>, the<br />

Order Server will not start.<br />

Password <strong>CME</strong> Group assigns this value to the customer and refers to<br />

it as the Password.<br />

ILinkPrimaryIP The exchange refers to this value as the IP address. The<br />

exchange provides the IP address, which is an IP address for<br />

a <strong>CME</strong> Group FIX Server through which the customer can<br />

connect to the exchange. The customer must use one of<br />

these addresses for the PrimaryIP.<br />

ILinkPrimaryPort The exchange refers to this value as the port. This is the port<br />

on the <strong>CME</strong> Group FIX Server which the <strong>TT</strong> <strong>Gateway</strong><br />

connects. If the exchange provides two port numbers, <strong>CME</strong><br />

Group assigns each port to a specific IP address. If this is the<br />

case, the customer must use the appropriate number for<br />

each of the port parameters.<br />

Table 4. [order_session_#] section parameters<br />

126 <strong>CME</strong> <strong>Gateway</strong> <strong>System</strong> <strong>Administration</strong> <strong>Manual</strong><br />

<strong>Trading</strong> Technologies International, Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!