A Configuration Parameters<br />

<strong>CME</strong> <strong>Gateway</strong> <strong>System</strong> <strong>Administration</strong> <strong>Manual</strong> 133<br />

<strong>Trading</strong> Technologies International, Inc.<br />

Parameter Description<br />

FastTemplates For 7.16.0 or higher versions, sets the location<br />

of the FAS<strong>TT</strong>emplates.xml file. The path to the<br />

file can be changed to a customized location<br />

relative to the <strong>TT</strong> configuration directory<br />

(\config) by configuring this parameter. By<br />

default, this parameter is not present and the<br />

gateway automatically locates the<br />

FAS<strong>TT</strong>emplates.xml file in the \config<br />

directory.<br />

For information on how the <strong>CME</strong> <strong>Gateway</strong> uses<br />

the FAS<strong>TT</strong>emplates.xml file, refer to the section<br />

called FIX/FAST Behavior on page 52.<br />

FASTSubject#=Subject/ Configures the type of data (i.e., products) to<br />

which the <strong>CME</strong> <strong>Gateway</strong> subscribes. You can<br />

subscribe to any market data that has a<br />

[fastInterface] section in the fast.cfg file.<br />

The value of this parameter must exactly match<br />

the value of a subject parameter in the fast.cfg<br />

file. The <strong>CME</strong> <strong>Gateway</strong> uses fast.cfg to<br />

determine how to connect to <strong>CME</strong> Group to<br />

subscribe to the specified data.<br />

The # in the FASTSubject# parameter starts at<br />

1 for the first subject you include and increases<br />

by 1 for each additional subject parameter you<br />

include in this section. Each # must be unique.<br />

The Price Server limits subscribing to more than<br />

14 FIX-FAST market data channels per <strong>CME</strong><br />

<strong>Gateway</strong>. For recommendations on which<br />

combinations of subject parameters to enable in<br />

order to configure the <strong>CME</strong> <strong>Gateway</strong> for<br />

optimal perfomance, refer to the section<br />

called Recommendations for Optimal<br />

Performance on page 58.<br />

Warning: If the <strong>CME</strong> <strong>Gateway</strong><br />

subscribes to more than 14 FIX-FAST<br />

market data channels, the Price Server<br />

immediately logs an error message and<br />

displays as Exchange Feed Down (half<br />

red, half green) in Guardian. If this occurs, you<br />

will need to adjust the number of FASTSubject#<br />

parameters enabled in the [price_session]<br />

section and restart the Price Server.<br />

NetworkInterfaceFeed*=IP Sets the IP Address of the <strong>CME</strong> Group-facing<br />

NIC. If you use multiple <strong>CME</strong> Group-facing NICs,<br />

using Feed* you must specify which MDP feed<br />

the <strong>TT</strong> <strong>Gateway</strong> routes over the NIC. The Feed*<br />

section of this parameter maps to the same<br />

section in the parameter AddressFeed* in the<br />

fast.cfg file. If you have only one <strong>CME</strong> Groupfacing<br />

NIC, use NetworkInterface=IP, the <strong>TT</strong><br />

<strong>Gateway</strong> uses this as the default NIC for all MDP<br />

feeds.<br />

For further details and examples, refer to the<br />

section called Configuring Multiple NIC<br />

Setup on page 41.<br />

Table 6. [price_session] section parameters